Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 2 Ton, R410A, Fin Tube, Southeast Region Only B77-440
Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 2 Ton, R410A, Fin Tube, Southeast Region Only
SEER: 14; EER: 11.7; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 13.6; Max. Fuse Size: 20; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29-1/4"; Height: 30"; Depth: 29-1/4"; Wt. Lbs.: 131; OEM TXV: B19-657; OEM TXV…
Brand: Coleman Mfg #: TF4B2421S

Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 2 Ton, R410A, Fin Tube B79-328
Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 2 Ton, R410A, Fin Tube
SEER: 13; EER: 11.0; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 14.5; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 24"; Height: 33-1/4"; Depth: 24"; Wt. Lbs.: 118; OEM TXV: B19-657; OEM TXV for…
Brand: Coleman Mfg #: TF3B2421S

Heat Pump GMC Series, 14 SEER, Single-Phase, 4 Ton, R410A B75-932
Heat Pump GMC Series, 14 SEER, Single-Phase, 4 Ton, R410A
SEER: 14; EER: 11.5; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 48,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 9; COP: 4.72; Min. Circuit Amps: 24.4; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 29"; Height: 36-1/4";…
Brand: Goodman Mfg #: VSZ140481

Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 4 Ton, R410A, Fin Tube B79-332
Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 4 Ton, R410A, Fin Tube
SEER: 13; EER: 11.0; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 25.7; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/4"; Height: 36-1/4"; Depth: 31-3/4"; Wt. Lbs.: 210; OEM TXV: B19-659; OEM…
Brand: Coleman Mfg #: TF3B4821S

Single Packaged Heat Pump 14 SEER, 4 Ton, Single-Phase, R410A B77-233
Single Packaged Heat Pump 14 SEER, 4 Ton, Single-Phase, R410A
SEER: 14; EER: 11; Nom. Tons: 4; BtuH Cooling: 45,500; BtuH Heating Input: 44,100; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8; COP: 3.5; Nom. CFM: 1,600; Min. Circuit Amps: 34.4; Refrigerant: R410A; Width: 45-3/4"; Height: 53"; Depth: 51-1/4"; Wt. Lbs.: 496;
Brand: Coleman Mfg #: PHE4A4821

Single Packaged Gas/Heat Air Conditioner 14 SEER, Three-Phase, 4 Ton, R410A, 81% AFUE, 208/230V, LOWNOx B63-660
Single Packaged Gas/Heat Air Conditioner 14 SEER, Three-Phase, 4 Ton, R410A, 81% AFUE, 208/230V, LOWNOx
SEER: 14; EER: 11.2; Nom. Tons: 4; BtuH Cooling: 45,500; BtuH Heating Input: 65,000; BtuH Heating Output: 53,000; Volts: 208/230V; Phase: Three; Nom. CFM: 1,600; Min. Circuit Amps: 20.1; Refrigerant: R410A; Width: 45-3/4; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 460;
Brand: Coleman Mfg #: PCG4B480653L1

Single Packaged Gas/Heat Air Conditioner 14 SEER, Three-Phase, 4 Ton, R410A, 81% AFUE, 460V, LOWNOx B63-663
Single Packaged Gas/Heat Air Conditioner 14 SEER, Three-Phase, 4 Ton, R410A, 81% AFUE, 460V, LOWNOx
SEER: 14; EER: 11.2; Nom. Tons: 4; BtuH Cooling: 45,500; BtuH Heating Input: 65,000; BtuH Heating Output: 53,000; Volts: 460V; Phase: Three; Nom. CFM: 1,600; Min. Circuit Amps: 11.5; Refrigerant: R410A; Width: 45-3/4; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 460;
Brand: Coleman Mfg #: PCG4B480654L1

Heat Pump GMC Series, 14 SEER, Single-Phase, 2 Ton, R410A B75-928
Heat Pump GMC Series, 14 SEER, Single-Phase, 2 Ton, R410A
SEER: 14; EER: 11.5; Nom. Tons: 2; BtuH Cooling: 30,000; BtuH Heating Input: 30,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.2; COP: 4.57; Min. Circuit Amps: 14.6; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29"; Height: 38-1/4"; Depth:…
Brand: Goodman Mfg #: VSZ140241

Single Packaged Heat Pump 14 SEER, 2 Ton, Single-Phase, R410A B77-229
Single Packaged Heat Pump 14 SEER, 2 Ton, Single-Phase, R410A
SEER: 14; EER: 11; Nom. Tons: 2; BtuH Cooling: 23,100; BtuH Heating Input: 21,900; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8; COP: 1.8; Nom. CFM: 800; Min. Circuit Amps: 17.4; Refrigerant: R410A; Width: 35-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 377;
Brand: Coleman Mfg #: PHE4A2421

Air Conditioning Condensing Unit GMC Series, 14 SEER, Single-Phase, 2 Ton, R410A B75-921
Air Conditioning Condensing Unit GMC Series, 14 SEER, Single-Phase, 2 Ton, R410A
SEER: 14; EER: 11.5; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 10.3; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 26"; Height: 27-1/2"; Depth: 26"; Wt. Lbs.: 131; OEM TXV: B18-099;
Brand: Goodman Mfg #: VSX140241

Single Packaged Air Conditioner 14 SEER, Three-Phase, 4 Ton, R410A B61-590
Single Packaged Air Conditioner 14 SEER, Three-Phase, 4 Ton, R410A
SEER: 14; EER: 11.0; Nom. Tons: 4; BtuH Cooling: 45,500; Volts: 460; Phase: Three; Motor Type: ECM; Nom. CFM: 1,600; Min. Circuit Amps: 27.6; Max. Fuse Size: 30; Refrigerant: R410A; Width: 45-3/4"; Height: 49"; Depth: 51-1/4"; Wt. Lbs.: 455;
Brand: Coleman Mfg #: PCE4B4842

Air Conditioning Condensing Unit GMC Series, 13 SEER, Single-Phase, 2.5 Ton, R410A B61-812
Air Conditioning Condensing Unit GMC Series, 13 SEER, Single-Phase, 2.5 Ton, R410A
SEER: 13; EER: 11; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208-230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 17.6; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 23"; Height: 25-3/4"; Depth: 23"; Wt. Lbs.: 113; OEM TXV: B18-099;
Brand: Goodman Mfg #: VSX130241

Air Conditioning Condensing Unit 13 SEER, Single-Phase, 4 Ton, R410A B74-878
Air Conditioning Condensing Unit 13 SEER, Single-Phase, 4 Ton, R410A
SEER: 13; EER: 11.0; Nom. Tons: 4; BtuH Cooling: 46,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 26.4; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 29"; Height: 36-1/4"; Depth: 29"; Wt. Lbs.: 225; OEM TXV: B14-851;
Brand: Amana Mfg #: ANX130481

Single Packaged Gas/Heat Air Conditioner LX Series, 14 SEER, Single-Phase, 4 Ton, R410A, 81% AFUE B61-587
Single Packaged Gas/Heat Air Conditioner LX Series, 14 SEER, Single-Phase, 4 Ton, R410A, 81% AFUE
SEER: 14; EER: 11.2; Nom. Tons: 4; BtuH Cooling: 45,500; BtuH Heating Input: 100,000; BtuH Heating Output: 80,000; Volts: 208/230V; Phase: Single; Nom. CFM: 1,600; Min. Circuit Amps: 34.4; Refrigerant: R410A; Width: 45-3/4"; Height: 49"; Depth: 51"; Wt. Lbs.: 473;
Brand: Coleman Mfg #: PCG4B481252X2

Gas/Electric Packaged Air Conditioner 13 SEER, Three-Phase, 4 Ton, R410A B74-188
Gas/Electric Packaged Air Conditioner 13 SEER, Three-Phase, 4 Ton, R410A
EER: 11.3; Nom. Tons: 4; BtuH Cooling: 45,500; BtuH Heating Input: 92,000; BtuH Heating Output: 74,000; Motor Type: Belt; Nom. CFM: 1,600; Min. Circuit Amps: 10; Width: 74-1/16"; Height: 38-13/16"; Depth: 48-3/16"; Wt. Lbs.: 575;
Brand: Daikin Mfg #: DCG0480904BXXX

Air Conditioning Condensing Unit 13 SEER, Single-Phase, 2 Ton, R410A B74-874
Air Conditioning Condensing Unit 13 SEER, Single-Phase, 2 Ton, R410A
SEER: 13; EER: 11.0; Nom. Tons: 2; BtuH Cooling: 23,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 17.8; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 26"; Height: 27-1/2"; Depth: 26"; Wt. Lbs.: 145; OEM TXV: B18-099;
Brand: Amana Mfg #: ANX130241

Heat Pump GMC Series, 13 SEER, Single-Phase, 5 Ton, R410A B75-679
Heat Pump GMC Series, 13 SEER, Single-Phase, 5 Ton, R410A
SEER: 14; EER: 11.5; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 48,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.5; COP: 4.39; Min. Circuit Amps: 26.4; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 35-1/2"; Height: 34-1/2";…
Brand: Goodman Mfg #: VSZ140491

Dual Fuel Packaged Heat Pump 14 SEER, Single-Phase, Single-Stage, 2 Ton, R410A B77-284
Dual Fuel Packaged Heat Pump 14 SEER, Single-Phase, Single-Stage, 2 Ton, R410A
SEER: 14; EER: 11; Nom. Tons: 2; BtuH Cooling: 23,100; BtuH Heating Input: 50,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 1.8; Nom. CFM: 800; Min. Circuit Amps: 15.8; Refrigerant: R410A; Width: 35-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 394;
Brand: Coleman Mfg #: PHG4A240502X1

Single Packaged Gas/Heat Air Conditioner 16 SEER, Three-Phase, 4 Ton, R410A, 81% AFUE B78-082
Single Packaged Gas/Heat Air Conditioner 16 SEER, Three-Phase, 4 Ton, R410A, 81% AFUE
SEER: 14; EER: 11; Nom. Tons: 4; BtuH Cooling: 45,500; BtuH Heating Input: 125,000; BtuH Heating Output: 100,000; Nom. CFM: 1,600; Min. Circuit Amps: 24.2; Width: 46; Height: 53; Depth: 51-1/4"; Wt. Lbs.: 533;
Brand: Coleman Mfg #: PCG4B481253X1

Dual Fuel Packaged Heat Pump 14 SEER, Single-Phase, Single-Stage, 4 Ton, R410A B77-294
Dual Fuel Packaged Heat Pump 14 SEER, Single-Phase, Single-Stage, 4 Ton, R410A
SEER: 14; EER: 11; Nom. Tons: 4; BtuH Cooling: 45,500; BtuH Heating Input: 125,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 3.5; Nom. CFM: 1,600; Min. Circuit Amps: 34.6; Refrigerant: R410A; Width: 45-3/4"; Height: 53"; Depth: 51-1/4"; Wt. Lbs.: 564;
Brand: Coleman Mfg #: PHG4B481252X1

Dual Fuel Packaged Heat Pump 14 SEER, Single-Phase, Single-Stage, 4 Ton, R410A B77-292
Dual Fuel Packaged Heat Pump 14 SEER, Single-Phase, Single-Stage, 4 Ton, R410A
SEER: 14; EER: 11; Nom. Tons: 4; BtuH Cooling: 45,500; BtuH Heating Input: 65,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 3.5; Nom. CFM: 1,600; Min. Circuit Amps: 34.6; Refrigerant: R410A; Width: 45-3/4"; Height: 53"; Depth: 51-1/4"; Wt. Lbs.: 551;
Brand: Coleman Mfg #: PHG4B480652X1

Dual Fuel Packaged Heat Pump 14 SEER, Single-Phase, Single-Stage, 4 Ton, R410A B77-293
Dual Fuel Packaged Heat Pump 14 SEER, Single-Phase, Single-Stage, 4 Ton, R410A
SEER: 14; EER: 11; Nom. Tons: 4; BtuH Cooling: 45,500; BtuH Heating Input: 100,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 3.5; Nom. CFM: 1,600; Min. Circuit Amps: 34.6; Refrigerant: R410A; Width: 45-3/4"; Height: 53"; Depth: 51-1/4"; Wt. Lbs.: 559;
Brand: Coleman Mfg #: PHG4B481002X1

Air Conditioning Condensing Unit Up to  15 SEER, Single-Phase, 2 Ton, R410A B76-757
Air Conditioning Condensing Unit Up to 15 SEER, Single-Phase, 2 Ton, R410A
SEER: 14; EER: 11.5; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 14.2; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 26"; Height: 27-1/2"; Depth: 26"; Wt. Lbs.: 126; OEM TXV: B18-099;
Brand: Amana Mfg #: ANX140241

Air Conditioning Condensing Unit GMC Series, 14 SEER, Single-Phase, 4 Ton, R410A B75-925
Air Conditioning Condensing Unit GMC Series, 14 SEER, Single-Phase, 4 Ton, R410A
SEER: 14; EER: 11.7; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 26.2; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 36-1/4"; Depth: 35-1/2"; Wt. Lbs.: 220; OEM TXV: B14-851;
Brand: Goodman Mfg #: VSX140481