36 Results

3, 2, 12 to 12.8, Coleman, HVAC Equipment

Air Conditioning Condensing Unit LX Series, 13 SEER, Three-Phase, 3 Ton, R410A B61-258
Air Conditioning Condensing Unit LX Series, 13 SEER, Three-Phase, 3 Ton, R410A
EER: 12.25; Nom. Tons: 3; Volts: 208/230; Phase: Three; Min. Circuit Amps: 14.34; Max. Fuse Size: 20; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29-1/4"; Height: 36-1/4"; Depth: 29-1/4"; Wt. Lbs.: 160;
Brand: Coleman Mfg #: TCD36B32S

Single Packaged Gas/Heat Air Conditioner LX Series, 16 SEER, Single-Phase, 3 Ton, R410A, 81% AFUE B64-226
Single Packaged Gas/Heat Air Conditioner LX Series, 16 SEER, Single-Phase, 3 Ton, R410A, 81% AFUE
SEER: 16; EER: 12.0; Nom. Tons: 3; BtuH Cooling: 35,800; BtuH Heating Input: 75,000; BtuH Heating Output: 60,000; Volts: 208/230; Phase: Single; Nom. CFM: 1,200; Min. Circuit Amps: 23.2; Refrigerant: R410A; Width: 35-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 466;
Brand: Coleman Mfg #: PCG6A360752X4

Single Packaged Gas/Heat Air Conditioner LX Series, 16 SEER, Single-Phase, 2 Ton, R410A, 81% AFUE B64-224
Single Packaged Gas/Heat Air Conditioner LX Series, 16 SEER, Single-Phase, 2 Ton, R410A, 81% AFUE
SEER: 16; EER: 12.5; Nom. Tons: 2; BtuH Cooling: 24,000; BtuH Heating Input: 50,000; BtuH Heating Output: 40,000; Volts: 208/230; Phase: Single; Nom. CFM: 750; Min. Circuit Amps: 16.1; Refrigerant: R410A; Width: 35-3/4"; Height: 44"; Depth: 51-1/4"; Wt. Lbs.: 372;
Brand: Coleman Mfg #: PCG6A240502X4

Single Packaged Gas/Heat Air Conditioner LX Series, 16 SEER, Single-Phase, 2 Ton, R410A, 81% AFUE B64-225
Single Packaged Gas/Heat Air Conditioner LX Series, 16 SEER, Single-Phase, 2 Ton, R410A, 81% AFUE
SEER: 16; EER: 12.5; Nom. Tons: 2; BtuH Cooling: 24,000; BtuH Heating Input: 75,000; BtuH Heating Output: 60,000; Volts: 208/230; Phase: Single; Nom. CFM: 750; Min. Circuit Amps: 16.1; Refrigerant: R410A; Width: 35-3/4"; Height: 44"; Depth: 51-1/4"; Wt. Lbs.: 382;
Brand: Coleman Mfg #: PCG6A240752X4

Air Conditioning Condensing Unit LX Series, 13 SEER, Three-Phase, 3 Ton, R410A B61-259
Air Conditioning Condensing Unit LX Series, 13 SEER, Three-Phase, 3 Ton, R410A
EER: 12.25; Nom. Tons: 3; Volts: 460; Phase: Three; Min. Circuit Amps: 7.85; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29-1/4"; Height: 36-1/4"; Depth: 29-1/4"; Wt. Lbs.: 160;
Brand: Coleman Mfg #: TCD36B42S

Heat Pump LX Series, 14 SEER, Single-Phase, 3 Ton, R410A B61-149
Heat Pump LX Series, 14 SEER, Single-Phase, 3 Ton, R410A
SEER: 14; EER: 12.75; Nom. Tons: 3; BtuH Cooling: 34,000; BtuH Heating Input: 36,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.2; COP: 3.72; Min. Circuit Amps: 21.99; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 38"; Height: 39-1/2";…
Brand: Coleman Mfg #: TH4B3622S

Air Conditioning Condensing Unit 20 SEER, Single-Phase, Modulating, 3 Ton, R410A B79-686
Air Conditioning Condensing Unit 20 SEER, Single-Phase, Modulating, 3 Ton, R410A
SEER: 20; EER: 12.75; Nom. Tons: 3; BtuH Cooling: 36,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 25.7; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 32"; Height: 40-1/4"; Depth: 35-1/2"; Wt. Lbs.: 205;
Brand: Coleman Mfg #: AC21B3621S

Air Conditioning Condensing Unit Horizontal Discharge, 14 SEER, Single-Phase, 2 Ton, R410A B60-174
Air Conditioning Condensing Unit Horizontal Discharge, 14 SEER, Single-Phase, 2 Ton, R410A
SEER: 14; EER: 12.2; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 18.3; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 45"; Height: 37-1/4"; Depth: 20"; Wt. Lbs.: 195; OEM TXV: B19-657; OEM TXV for…
Brand: Coleman Mfg #: TCHE24S41S1

Air Conditioning Condensing Unit Horizontal Discharge, 14 SEER, Single-Phase, 3 Ton, R410A B60-175
Air Conditioning Condensing Unit Horizontal Discharge, 14 SEER, Single-Phase, 3 Ton, R410A
SEER: 14; EER: 12.2; Nom. Tons: 3; BtuH Cooling: 36,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 19.1; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 45"; Height: 37-1/4"; Depth: 20"; Wt. Lbs.: 215; OEM TXV: B20-259; OEM TXV for…
Brand: Coleman Mfg #: TCHE36S41S1

Air Conditioning Condensing Unit LX Series, 17 SEER, Single-Phase, 3 Ton, R410A B78-420
Air Conditioning Condensing Unit LX Series, 17 SEER, Single-Phase, 3 Ton, R410A
SEER: 17; EER: 12.5; Nom. Tons: 3; BtuH Cooling: 36,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 22.0; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 35-1/4"; Height: 36-1/4"; Depth: 31-3/4"; Wt. Lbs.: 175; OEM TXV: B19-657; OEM…
Brand: Coleman Mfg #: CC7B3621S

Heat Pump LX Series, 14 SEER, Single-Phase, 2 Ton, R410A B78-391
Heat Pump LX Series, 14 SEER, Single-Phase, 2 Ton, R410A
SEER: 14; EER: 12.75; Nom. Tons: 2; BtuH Cooling: 23,800; BtuH Heating Input: 24,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.2; COP: 3.96; Min. Circuit Amps: 15.4; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29-1/4"; Height: 36-1/4";…
Brand: Coleman Mfg #: TH4B2421S

Heat Pump LX Series, 14 SEER, Single-Phase, 3 Ton, R410A B78-393
Heat Pump LX Series, 14 SEER, Single-Phase, 3 Ton, R410A
SEER: 14; EER: 12; Nom. Tons: 3; BtuH Cooling: 35,200; BtuH Heating Input: 35,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.2; COP: 3.76; Min. Circuit Amps: 20.5; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 35-1/4"; Height: 39-1/2";…
Brand: Coleman Mfg #: TH4B3521S

Heat Pump LX Series, 14 SEER, Single-Phase, 3 Ton, R410A B62-865
Heat Pump LX Series, 14 SEER, Single-Phase, 3 Ton, R410A
SEER: 14; EER: 12.0; Nom. Tons: 3; BtuH Cooling: 35,000; BtuH Heating Input: 34,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.55; COP: 3.40; Min. Circuit Amps: 19.6; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 35-1/4"; Height: 36-1/4";…
Brand: Coleman Mfg #: TE4B3621S

Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 2 Ton, R410A, Southwest Region Only B62-066
Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 2 Ton, R410A, Southwest Region Only
SEER: 14; EER: 12.2; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 14.8; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29-1/4"; Height: 30"; Depth: 29-1/4"; Wt. Lbs.: 135; OEM TXV: B20-469; OEM TXV…
Brand: Coleman Mfg #: TW4B2422S

Heat Pump LX Series, 14 SEER, Single-Phase, 2 Ton, R410A B62-863
Heat Pump LX Series, 14 SEER, Single-Phase, 2 Ton, R410A
SEER: 14; EER: 12.0; Nom. Tons: 2; BtuH Cooling: 25,000; BtuH Heating Input: 22,200; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 9.0; COP: 3.68; Min. Circuit Amps: 14.1; Max. Fuse Size: 20; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 24"; Height: 33-1/4"; Depth:…
Brand: Coleman Mfg #: TE4B2421S

Single Packaged Air Conditioner 16 SEER, Single-Phase, 3 Ton, R410A B64-149
Single Packaged Air Conditioner 16 SEER, Single-Phase, 3 Ton, R410A
SEER: 16; EER: 12.5; Nom. Tons: 3; BtuH Cooling: 36,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Nom. CFM: 1,275; Min. Circuit Amps: 23.2; Max. Fuse Size: 35; Refrigerant: R410A; Width: 35-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 461;
Brand: Coleman Mfg #: PCE6A3624

Single Packaged Air Conditioner 16 SEER, Single-Phase, 2 Ton, R410A B64-148
Single Packaged Air Conditioner 16 SEER, Single-Phase, 2 Ton, R410A
SEER: 16; EER: 12.5; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Nom. CFM: 750; Min. Circuit Amps: 17.3; Max. Fuse Size: 25; Refrigerant: R410A; Width: 35-3/4"; Height: 44"; Depth: 51-1/4"; Wt. Lbs.: 343;
Brand: Coleman Mfg #: PCE6A2424

Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 3 Ton, R410A, Southwest Region Only B62-068
Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 3 Ton, R410A, Southwest Region Only
SEER: 14; EER: 12.2; Nom. Tons: 3; BtuH Cooling: 36,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 19.62; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29-1/4"; Height: 36-1/4"; Depth: 29-1/4"; Wt. Lbs.: 160; OEM TXV: B19-657; OEM…
Brand: Coleman Mfg #: TW4B3622S

Single Packaged Heat Pump 16 SEER, 2 Ton, Single-Phase, R410A B79-383
Single Packaged Heat Pump 16 SEER, 2 Ton, Single-Phase, R410A
SEER: 16; EER: 12.5; Nom. Tons: 2; BtuH Cooling: 23,500; BtuH Heating Input: 22,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.2; COP: 3.7; Nom. CFM: 800; Min. Circuit Amps: 19.1; Refrigerant: R410A; Width: 35-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 377;
Brand: Coleman Mfg #: PHE6A2421

Single Packaged Gas/Heat Air Conditioner 16 SEER, Three-Phase, 3 Ton, R410A, 81% AFUE, 208/230V B64-233
Single Packaged Gas/Heat Air Conditioner 16 SEER, Three-Phase, 3 Ton, R410A, 81% AFUE, 208/230V
SEER: 16; EER: 12.5; Nom. Tons: 3; BtuH Cooling: 36,000; BtuH Heating Input: 75,000; BtuH Heating Output: 60,000; Volts: 208/230; Phase: Three; Motor Type: ECM; Nom. CFM: 1,275; Min. Circuit Amps: 16.6; Refrigerant: R410A; Width: 35-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 466;
Brand: Coleman Mfg #: PCG6A360753X4

Single Packaged Gas/Heat Air Conditioner 16 SEER, Three-Phase, 3 Ton, R410A, 81% AFUE, 460V B64-238
Single Packaged Gas/Heat Air Conditioner 16 SEER, Three-Phase, 3 Ton, R410A, 81% AFUE, 460V
SEER: 16; EER: 12.5; Nom. Tons: 3; BtuH Cooling: 36,000; BtuH Heating Input: 75,000; BtuH Heating Output: 60,000; Volts: 460; Phase: Three; Motor Type: ECM; Nom. CFM: 1,275; Min. Circuit Amps: 7.7; Refrigerant: R410A; Width: 35-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 466;
Brand: Coleman Mfg #: PCG6A360754X4

Single Packaged Air Conditioner 16 SEER, Single-Phase, 3 Ton, R410A B79-391
Single Packaged Air Conditioner 16 SEER, Single-Phase, 3 Ton, R410A
SEER: 16; EER: 12.5; Nom. Tons: 3; BtuH Cooling: 36,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Nom. CFM: 1,200; Min. Circuit Amps: 25; Max. Fuse Size: 40; Refrigerant: R410A; Width: 45-3/4"; Height: 49"; Depth: 51-1/4"; Wt. Lbs.: 460;
Brand: Coleman Mfg #: PCE6B3621

Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 2 Ton, R410A, Southwest Region Only B77-433
Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 2 Ton, R410A, Southwest Region Only
SEER: 14; EER: 12.2; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 13.6; Max. Fuse Size: 20; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29-1/4"; Height: 30"; Depth: 29-1/4"; Wt. Lbs.: 135; OEM TXV: B19-657; OEM TXV…
Brand: Coleman Mfg #: TW4B2421S

Single Packaged Heat Pump 16 SEER, 3 Ton, Single-Phase, R410A B79-385
Single Packaged Heat Pump 16 SEER, 3 Ton, Single-Phase, R410A
SEER: 16; EER: 12.5; Nom. Tons: 3; BtuH Cooling: 36,400; BtuH Heating Input: 33,300; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.2; COP: 3.6; Nom. CFM: 1,200; Min. Circuit Amps: 25.0; Refrigerant: R410A; Width: 45-3/4"; Height: 49"; Depth: 51-1/4"; Wt. Lbs.: 448;
Brand: Coleman Mfg #: PHE6B3621