15 Results

3-1/2, 12 to 12.8, Coleman, HVAC Equipment

Air Conditioning Condensing Unit LX Series, 13 SEER, Three-Phase, 3-1/2 Ton, R410A B61-260
Air Conditioning Condensing Unit LX Series, 13 SEER, Three-Phase, 3-1/2 Ton, R410A
EER: 12.25; Nom. Tons: 3-1/2; Volts: 208/230; Phase: Three; Min. Circuit Amps: 15.29; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/4"; Height: 33-1/4"; Depth: 31-3/4"; Wt. Lbs.: 200;
Brand: Coleman Mfg #: TCD42B32S

Air Conditioning Condensing Unit LX Series, 13 SEER, Three-Phase, 3-1/2 Ton, R410A B61-261
Air Conditioning Condensing Unit LX Series, 13 SEER, Three-Phase, 3-1/2 Ton, R410A
EER: 12.25; Nom. Tons: 3-1/2; Volts: 460; Phase: Three; Min. Circuit Amps: 7.68; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/4"; Height: 33-1/4"; Depth: 31-3/4"; Wt. Lbs.: 200;
Brand: Coleman Mfg #: TCD42B42S

Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 3-1/2 Ton, R410A, Southwest Region Only B77-436
Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 3-1/2 Ton, R410A, Southwest Region Only
SEER: 14; EER: 12.2; Nom. Tons: 3-1/2; BtuH Cooling: 42,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 22.1; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/4"; Height: 33-1/4"; Depth: 31-3/4"; Wt. Lbs.: 200; OEM TXV: B19-659;…
Brand: Coleman Mfg #: TW4B4221S

Air Conditioning Condensing Unit LX Series, 17 SEER, Single-Phase, 3-1/2 Ton, R410A B78-421
Air Conditioning Condensing Unit LX Series, 17 SEER, Single-Phase, 3-1/2 Ton, R410A
SEER: 17; EER: 12.75; Nom. Tons: 3-1/2; BtuH Cooling: 42,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 23.6; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 38"; Height: 39-1/2"; Depth: 34-1/4"; Wt. Lbs.: 220; OEM TXV: B19-658; OEM…
Brand: Coleman Mfg #: CC7B4221S

Dual Fuel Packaged Heat Pump 16 SEER, Single-Phase, Single-Stage, 3.5 Ton, R410A B60-883
Dual Fuel Packaged Heat Pump 16 SEER, Single-Phase, Single-Stage, 3.5 Ton, R410A
SEER: 16; EER: 12.5; Nom. Tons: 3.5; BtuH Cooling: 42,500; BtuH Heating Input: 100,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.2; COP: 3.6; Nom. CFM: 1,400; Min. Circuit Amps: 29.5; Refrigerant: R410A; Width: 45-3/4"; Height: 49"; Depth: 51-1/4"; Wt. Lbs.: 534;
Brand: Coleman Mfg #: PHG6B421002X1

Dual Fuel Packaged Heat Pump 16 SEER, Single-Phase, Single-Stage, 3.5 Ton, R410A B60-882
Dual Fuel Packaged Heat Pump 16 SEER, Single-Phase, Single-Stage, 3.5 Ton, R410A
SEER: 16; EER: 12.5; Nom. Tons: 3.5; BtuH Cooling: 42,500; BtuH Heating Input: 65,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.2; COP: 3.6; Nom. CFM: 1,400; Min. Circuit Amps: 29.5; Refrigerant: R410A; Width: 45-3/4"; Height: 49"; Depth: 51-1/4"; Wt. Lbs.: 532;
Brand: Coleman Mfg #: PHG6B420652X1

Heat Pump LX Series, 14 SEER, Single-Phase, 3-1/2 Ton, R410A B61-262
Heat Pump LX Series, 14 SEER, Single-Phase, 3-1/2 Ton, R410A
SEER: 14; EER: 12.00; Nom. Tons: 3-1/2; BtuH Cooling: 41,500; BtuH Heating Input: 42,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.3; COP: 3.86; Min. Circuit Amps: 25.5; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/4"; Height:…
Brand: Coleman Mfg #: TH4B4223S

Heat Pump LX Series, 14 SEER, Single-Phase, 3-1/2 Ton, R410A B62-866
Heat Pump LX Series, 14 SEER, Single-Phase, 3-1/2 Ton, R410A
SEER: 14; EER: 12.0; Nom. Tons: 3-1/2; BtuH Cooling: 41,000; BtuH Heating Input: 39,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.2; COP: 3.52; Min. Circuit Amps: 23.5; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/4"; Height: 36-1/4";…
Brand: Coleman Mfg #: TE4B4221S

Heat Pump LX Series, 14 SEER, Three-Phase, 3-1/2 Ton, R410A B61-265
Heat Pump LX Series, 14 SEER, Three-Phase, 3-1/2 Ton, R410A
SEER: 14; EER: 12.00; Nom. Tons: 3-1/2; HSPF: 9.00; COP: 3.62; Min. Circuit Amps: 16.1; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/4"; Height: 39-1/2"; Depth: 31-3/4"; Wt. Lbs.: 230;
Brand: Coleman Mfg #: THE42B32S

Heat Pump LX Series, 14 SEER, Three-Phase, 3-1/2 Ton, R410A B61-266
Heat Pump LX Series, 14 SEER, Three-Phase, 3-1/2 Ton, R410A
SEER: 14; EER: 12.00; Nom. Tons: 3-1/2; HSPF: 9.00; COP: 3.62; Min. Circuit Amps: 7.25; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/4"; Height: 39-1/2"; Depth: 31-3/4"; Wt. Lbs.: 230;
Brand: Coleman Mfg #: THE42B42S

Heat Pump LX Series, 14 SEER, Three-Phase, 3-1/2 Ton, R410A B79-363
Heat Pump LX Series, 14 SEER, Three-Phase, 3-1/2 Ton, R410A
SEER: 14; EER: 12.00; Nom. Tons: 3-1/2; HSPF: 9.00; COP: 3.62; Min. Circuit Amps: 7.25; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/4"; Height: 39-1/2"; Depth: 31-3/4"; Wt. Lbs.: 230;
Brand: Coleman Mfg #: THE42B41S

Single Packaged Gas/Heat Air Conditioner 16 SEER, Three-Phase, 3-1/2 Ton, R410A, 81% AFUE B60-726
Single Packaged Gas/Heat Air Conditioner 16 SEER, Three-Phase, 3-1/2 Ton, R410A, 81% AFUE
SEER: 16.0; EER: 12.5; Nom. Tons: 3-1/2; BtuH Cooling: 42,500; BtuH Heating Input: 100,000; BtuH Heating Output: 81,000; Volts: 208/230; Phase: Three; Motor Type: ECM; Nom. CFM: 1,400; Min. Circuit Amps: 12.2; Refrigerant: R410A; Width: 45-3/4"; Height: 49"; Depth: 51-1/4"; Wt. Lbs.: 497;
Brand: Coleman Mfg #: PCG6B421003X1

Single Packaged Gas/Heat Air Conditioner 16 SEER, Three-Phase, 3-1/2 Ton, R410A, 81% AFUE B60-725
Single Packaged Gas/Heat Air Conditioner 16 SEER, Three-Phase, 3-1/2 Ton, R410A, 81% AFUE
SEER: 16.0; EER: 12.5; Nom. Tons: 3-1/2; BtuH Cooling: 42,500; BtuH Heating Input: 65,000; BtuH Heating Output: 52,000; Volts: 208/230; Phase: Three; Motor Type: ECM; Nom. CFM: 1,400; Min. Circuit Amps: 12.2; Refrigerant: R410A; Width: 45-3/4"; Height: 49"; Depth: 51-1/4"; Wt. Lbs.: 495;
Brand: Coleman Mfg #: PCG6B420653X1

Single Packaged Gas/Heat Air Conditioner 16 SEER, Three-Phase, 3-1/2 Ton, R410A, 81% AFUE B79-928
Single Packaged Gas/Heat Air Conditioner 16 SEER, Three-Phase, 3-1/2 Ton, R410A, 81% AFUE
SEER: 16; EER: 12.5; Nom. Tons: 3-1/2; BtuH Cooling: 42,500; BtuH Heating Input: 65,000; BtuH Heating Output: 52,000; Volts: 460; Phase: Three; Motor Type: ECM; Nom. CFM: 1,400; Min. Circuit Amps: 12.2; Refrigerant: R410A; Width: 45-3/4"; Height: 49"; Depth: 51-1/4"; Wt. Lbs.: 495;
Brand: Coleman Mfg #: PCG6B420654X1

Single Packaged Gas/Heat Air Conditioner 16 SEER, Three-Phase, 3-1/2 Ton, R410A, 81% AFUE B79-929
Single Packaged Gas/Heat Air Conditioner 16 SEER, Three-Phase, 3-1/2 Ton, R410A, 81% AFUE
SEER: 16; EER: 12.5; Nom. Tons: 3-1/2; BtuH Cooling: 42,500; BtuH Heating Input: 100,000; BtuH Heating Output: 81,000; Volts: 460; Phase: Three; Motor Type: ECM; Nom. CFM: 1,400; Min. Circuit Amps: 12.2; Refrigerant: R410A; Width: 45-3/4"; Height: 49"; Depth: 51-1/4"; Wt. Lbs.: 497;
Brand: Coleman Mfg #: PCG6B421004X1
FTL Finance
Powered by Site Search powered by SLI Systems
Select products to compare.
Compare