Single Packaged Heat Pump 14 SEER/11.5 EER, Three-Phase, 4 Ton, R410A B62-906
Single Packaged Heat Pump 14 SEER/11.5 EER, Three-Phase, 4 Ton, R410A
Nom. Tons: 4; BtuH Cooling: 46,000; BtuH Heating Input: 45,500; EER: 11.5; HSPF: 8.0; COP: 2.34; Motor Type: Belt Drive; Volts: 208/230; Nom. CFM: 1,460; Min. Circuit Amps: 21.20; Width: 74"; Height: 39-7/8"; Depth: 48-5/16"; Wt. Lbs.: 640;
Brand: Daikin Mfg #: DBH0483B000001S

Single Packaged Heat Pump 14 SEER, Three-Phase, 4 Tons, R410A, Multi-Position B79-263
Single Packaged Heat Pump 14 SEER, Three-Phase, 4 Tons, R410A, Multi-Position
Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 45,500; EER: 11.00; HSPF: 8.2; COP: 2.2; Motor Type: Multi-Speed, ECM; Volts: 208/230; Nom. CFM: 1,600; Min. Circuit Amps: 23.9; Width: 47"; Height: 42-3/4"; Depth: 51"; Wt. Lbs.: 475;
Brand: Daikin Mfg #: DP14HM4843

Single Packaged Heat Pump 15 SEER/12.5 EER, Three-Phase, 4 Ton, R410A B61-139
Single Packaged Heat Pump 15 SEER/12.5 EER, Three-Phase, 4 Ton, R410A
Nom. Tons: 4; BtuH Cooling: 47,000; BtuH Heating Input: 44,000; EER: 12.5; HSPF: 8.0; COP: 3.8; Motor Type: Direct Drive; Volts: 208/230; Nom. CFM: 1,600; Min. Circuit Amps: 24.7; Width: 74-61/1000"; Height: 38-21/25"; Depth: 48-49/250"; Wt. Lbs.: 549;
Brand: Daikin Mfg #: DTH048XXX3DXXX

Single Packaged Heat Pump Up tp 17.0 IEER/12.6 EER Three-Phase 4 Ton, R410A, Direct Drive B64-761
Single Packaged Heat Pump Up tp 17.0 IEER/12.6 EER Three-Phase 4 Ton, R410A, Direct Drive
Nom. Tons: 4; BtuH Cooling: 48,000; EER: 12.6; HSPF: 8.2; COP: 4.0; Motor Type: Direct Drive; Volts: 208/230; Nom. CFM: 1,600; Min. Circuit Amps: 27.9; Width: 74"; Height: 43-1/2"; Depth: 48-5/16"; Wt. Lbs.: 621;
Brand: Daikin Mfg #: DRH0483D000001S

Single Packaged Heat Pump Up tp 17.0 IEER/12.6 EER Three-Phase 3 Ton, R410A, Direct Drive B64-765
Single Packaged Heat Pump Up tp 17.0 IEER/12.6 EER Three-Phase 3 Ton, R410A, Direct Drive
Nom. Tons: 4; BtuH Cooling: 48,000; EER: 12.6; HSPF: 8.2; COP: 4.0; Motor Type: Direct Drive; Volts: 460; Nom. CFM: 1,600; Min. Circuit Amps: 12.1; Width: 74"; Height: 43-1/2"; Depth: 48-5/16"; Wt. Lbs.: 621;
Brand: Daikin Mfg #: DRH0484D000001S

Single Packaged Heat Pump 14 SEER/11.5 EER, Three-Phase, 4 Ton, R410A B62-910
Single Packaged Heat Pump 14 SEER/11.5 EER, Three-Phase, 4 Ton, R410A
Nom. Tons: 4; BtuH Cooling: 46,000; BtuH Heating Input: 45,500; EER: 11.5; HSPF: 8.0; COP: 2.34; Motor Type: Belt Drive; Volts: 460; Nom. CFM: 1,460; Min. Circuit Amps: 10.00; Width: 74"; Height: 39-7/8"; Depth: 48-5/16"; Wt. Lbs.: 642;
Brand: Daikin Mfg #: DBH0484B000001S

Single Packaged Heat Pump 14 SEER/11.5 EER, Three-Phase, 4 Ton, R410A B62-905
Single Packaged Heat Pump 14 SEER/11.5 EER, Three-Phase, 4 Ton, R410A
Nom. Tons: 4; BtuH Cooling: 46,500; BtuH Heating Input: 45,500; EER: 11.5; HSPF: 8.0; COP: 2.34; Motor Type: Direct Drive; Volts: 208/230; Nom. CFM: 1,460; Min. Circuit Amps: 24.70; Width: 74"; Height: 39-7/8"; Depth: 48-5/16"; Wt. Lbs.: 589;
Brand: Daikin Mfg #: DBH0483D000001S

Single Packaged Heat Pump 13 SEER, Three-Phase, 4 Tons, R410A, Multi-Position B74-109
Single Packaged Heat Pump 13 SEER, Three-Phase, 4 Tons, R410A, Multi-Position
Nom. Tons: 4; BtuH Cooling: 47,000; BtuH Heating Input: 47,000; HSPF: 8.0; COP: 3.7; Volts: 208/230; Nom. CFM: 1,690; Min. Circuit Amps: 24.3; Width: 47"; Height: 42-3/4"; Depth: 51"; Wt. Lbs.: 485;
Brand: Daikin Mfg #: DP13HM4843

Single Packaged Heat Pump 16 SEER, 4 Ton, Three-Phase, R410A B79-937
Single Packaged Heat Pump 16 SEER, 4 Ton, Three-Phase, R410A
Nom. Tons: 4; BtuH Cooling: 47,500; BtuH Heating Input: 47,400; EER: 12.5; HSPF: 8.2; COP: 3.6; Motor Type: ECM; Volts: 460; Nom. CFM: 1,600; Min. Circuit Amps: 24.6; Width: 45-3/4"; Height: 53"; Depth: 51-1/4"; Wt. Lbs.: 496;
Brand: Coleman Mfg #: PHE6B4841

Single Packaged Heat Pump 16 SEER, 4 Ton, Three-Phase, R410A B77-562
Single Packaged Heat Pump 16 SEER, 4 Ton, Three-Phase, R410A
Nom. Tons: 4; BtuH Cooling: 47,500; BtuH Heating Input: 47,400; EER: 12.5; HSPF: 8.2; COP: 3.6; Motor Type: ECM; Volts: 208/230; Nom. CFM: 1,600; Min. Circuit Amps: 24.6; Width: 45-3/4"; Height: 53"; Depth: 51-1/4"; Wt. Lbs.: 496;
Brand: Coleman Mfg #: PHE6B4831

Single Packaged Heat Pump 14 SEER/12 EER, Three-Phase, 4 Ton, R410A Belt Drive B79-494
Single Packaged Heat Pump 14 SEER/12 EER, Three-Phase, 4 Ton, R410A Belt Drive
Nom. Tons: 4; BtuH Cooling: 46,500; BtuH Heating Input: 45,500; EER: 12.0; HSPF: 8.0; COP: 3.6; Motor Type: Belt; Volts: 208/230V; Nom. CFM: 1,600; Min. Circuit Amps: 21.2; Width: 73-189/200"; Height: 38-21/25"; Depth: 48-49/250"; Wt. Lbs.: 585;
Brand: Daikin Mfg #: DSH048XXX3BXXX

Single Packaged Heat Pump 14 SEER/12 EER, Three-Phase, 4 Ton, R410A Belt Drive B79-495
Single Packaged Heat Pump 14 SEER/12 EER, Three-Phase, 4 Ton, R410A Belt Drive
Nom. Tons: 4; BtuH Cooling: 46,500; BtuH Heating Input: 45,500; EER: 12.0; HSPF: 8.0; COP: 3.6; Motor Type: Belt; Volts: 460V; Nom. CFM: 1,600; Min. Circuit Amps: 10; Width: 73-189/200"; Height: 38-21/25"; Depth: 48-49/250"; Wt. Lbs.: 585;
Brand: Daikin Mfg #: DSH048XXX4BXXX