66 Results

Daikin, Packaged Heat Pumps, Single Packaged Units, Commercial, HVAC Equipment

Single Packaged Heat Pump 14 SEER/11.5 EER, Three-Phase, 4 Ton, R410A B62-906
Single Packaged Heat Pump 14 SEER/11.5 EER, Three-Phase, 4 Ton, R410A
Nom. Tons: 4; BtuH Cooling: 46,000; BtuH Heating Input: 45,500; EER: 11.5; HSPF: 8.0; COP: 2.34; Motor Type: Belt Drive; Volts: 208/230; Nom. CFM: 1,460; Min. Circuit Amps: 21.20; Width: 74"; Height: 39-7/8"; Depth: 48-5/16"; Wt. Lbs.: 640;
Brand: Daikin Mfg #: DBH0483B000001S

Single Packaged Heat Pump 12.5 IEER/11.2 EER,Three-Phase, 7-1/2 Ton, R410A B64-390
Single Packaged Heat Pump 12.5 IEER/11.2 EER,Three-Phase, 7-1/2 Ton, R410A
Nom. Tons: 7-1/2; BtuH Cooling: 88,000; BtuH Heating Input: 80,000; EER: 11.2; HSPF: 8.0; COP: 3.3; Motor Type: 2-Speed Belt; Volts: 460V; Nom. CFM: 2,850; Min. Circuit Amps: 19.8; Width: 93-3/4"; Height: 54-1/4"; Depth: 60-3/8"; Wt. Lbs.: 1,162;
Brand: Daikin Mfg #: DBH0904V000001S

Single Packaged Heat Pump 14 SEER, Three-Phase, 5 Tons, R410A, Multi-Position B79-264
Single Packaged Heat Pump 14 SEER, Three-Phase, 5 Tons, R410A, Multi-Position
Nom. Tons: 5; BtuH Cooling: 58,000; BtuH Heating Input: 57,000; EER: 11.00; HSPF: 8.3; COP: 2.2; Motor Type: Multi-Speed, ECM; Volts: 208/230; Nom. CFM: 1,850; Min. Circuit Amps: 29.6; Width: 47"; Height: 42-3/4"; Depth: 51"; Wt. Lbs.: 495;
Brand: Daikin Mfg #: DP14HM6043

Single Packaged Heat Pump 14 SEER/11.5 EER, Three-Phase, 3 Ton, R410A B62-904
Single Packaged Heat Pump 14 SEER/11.5 EER, Three-Phase, 3 Ton, R410A
Nom. Tons: 3; BtuH Cooling: 35,000; BtuH Heating Input: 34,200; EER: 11.5; HSPF: 8.0; COP: 2.34; Motor Type: Belt Drive; Volts: 208/230; Nom. CFM: 1,170; Min. Circuit Amps: 17.40; Width: 74"; Height: 39-7/8"; Depth: 48-5/16"; Wt. Lbs.: 605;
Brand: Daikin Mfg #: DBH0363B000001S

Single Packaged Heat Pump 12.5 IEER/10.6 EER,Three-Phase, 12-1/2 Ton, R410A B65-351
Single Packaged Heat Pump 12.5 IEER/10.6 EER,Three-Phase, 12-1/2 Ton, R410A
Nom. Tons: 12-1/2; BtuH Cooling: 140,000; BtuH Heating Input: 140,000; EER: 10.6; HSPF: 8.0; COP: 3.2; Motor Type: 2-Speed Belt; Volts: 208/230V; Nom. CFM: 4,250; Min. Circuit Amps: 65.0; Width: 93-3/4"; Height: 58-3/5"; Depth: 60-3/8"; Wt. Lbs.: 1,314;
Brand: Daikin Mfg #: DBH1503V000001S

Single Packaged Heat Pump 12.5 IEER/11.0 EER,Three-Phase, 8-1/2 Ton, R410A B64-396
Single Packaged Heat Pump 12.5 IEER/11.0 EER,Three-Phase, 8-1/2 Ton, R410A
Nom. Tons: 8-1/2; BtuH Cooling: 99,000; BtuH Heating Input: 94,000; EER: 11.0; HSPF: 8.0; COP: 3.3; Motor Type: 2-Speed Belt; Volts: 208/230V; Nom. CFM: 3,400; Min. Circuit Amps: 45.6; Width: 93-3/4"; Height: 54-1/4"; Depth: 60-3/8"; Wt. Lbs.: 1,212;
Brand: Daikin Mfg #: DBH1023V000001S

Single Packaged Heat Pump Up tp 17.0 IEER/12.6 EER Three-Phase 6 Ton, R410A, Direct Drive B63-679
Single Packaged Heat Pump Up tp 17.0 IEER/12.6 EER Three-Phase 6 Ton, R410A, Direct Drive
Nom. Tons: 6; BtuH Cooling: 69,000; EER: 11.5; COP: 3.4; Motor Type: Direct Drive; Volts: 208/230; Nom. CFM: 2,200; Min. Circuit Amps: 29.0; Width: 74"; Height: 53-3/4"; Depth: 48-5/16"; Wt. Lbs.: 708;
Brand: Daikin Mfg #: DRH0723D000001S

Single Packaged Heat Pump 14 SEER, Three-Phase, 3 Ton, R410A, Multi-Position B79-262
Single Packaged Heat Pump 14 SEER, Three-Phase, 3 Ton, R410A, Multi-Position
Nom. Tons: 3; BtuH Cooling: 34,400; BtuH Heating Input: 33,200; EER: 11.00; HSPF: 8.1; COP: 2.2; Motor Type: Multi-Speed, ECM; Volts: 208/230; Nom. CFM: 1,200; Min. Circuit Amps: 18.2; Width: 47"; Height: 34-3/4"; Depth: 51"; Wt. Lbs.: 400;
Brand: Daikin Mfg #: DP14HM3643

Single Packaged Heat Pump 14 SEER/11.5 EER, Three-Phase, 5 Ton, R410A B62-908
Single Packaged Heat Pump 14 SEER/11.5 EER, Three-Phase, 5 Ton, R410A
Nom. Tons: 5; BtuH Cooling: 56,500; BtuH Heating Input: 56,500; EER: 11.5; HSPF: 8.0; COP: 2.34; Motor Type: Belt Drive; Volts: 208/230; Nom. CFM: 1,460; Min. Circuit Amps: 25.40; Width: 74"; Height: 43-1/2"; Depth: 48-5/16"; Wt. Lbs.: 686;
Brand: Daikin Mfg #: DBH0603B000001S

Single Packaged Heat Pump 14 SEER/11.5 EER, Three-Phase, 5 Ton, R410A B62-911
Single Packaged Heat Pump 14 SEER/11.5 EER, Three-Phase, 5 Ton, R410A
Nom. Tons: 5; BtuH Cooling: 56,500; BtuH Heating Input: 56,500; EER: 11.5; HSPF: 8.0; COP: 2.34; Motor Type: Belt Drive; Volts: 460; Nom. CFM: 1,790; Min. Circuit Amps: 11.40; Width: 74"; Height: 43-1/2"; Depth: 48-5/16"; Wt. Lbs.: 693;
Brand: Daikin Mfg #: DBH0604B000001S

Single Packaged Heat Pump 14 SEER/11.5 EER, Three-Phase, 5 Ton, R410A B62-907
Single Packaged Heat Pump 14 SEER/11.5 EER, Three-Phase, 5 Ton, R410A
Nom. Tons: 5; BtuH Cooling: 56,500; BtuH Heating Input: 56,500; EER: 11.5; HSPF: 8.0; COP: 2.34; Motor Type: Direct Drive; Volts: 208/230; Nom. CFM: 1,790; Min. Circuit Amps: 29.10; Width: 74"; Height: 43-1/2"; Depth: 48-5/16"; Wt. Lbs.: 632;
Brand: Daikin Mfg #: DBH0603D000001S

Single Packaged Heat Pump 14 SEER, Three-Phase, 4 Tons, R410A, Multi-Position B79-263
Single Packaged Heat Pump 14 SEER, Three-Phase, 4 Tons, R410A, Multi-Position
Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 45,500; EER: 11.00; HSPF: 8.2; COP: 2.2; Motor Type: Multi-Speed, ECM; Volts: 208/230; Nom. CFM: 1,600; Min. Circuit Amps: 23.9; Width: 47"; Height: 42-3/4"; Depth: 51"; Wt. Lbs.: 475;
Brand: Daikin Mfg #: DP14HM4843

Single Packaged Heat Pump 12.5 IEER/11.0 EER,Three-Phase, 10 Ton, R410A B64-399
Single Packaged Heat Pump 12.5 IEER/11.0 EER,Three-Phase, 10 Ton, R410A
Nom. Tons: 10; BtuH Cooling: 112,000; BtuH Heating Input: 106,000; EER: 11.0; HSPF: 8.0; COP: 3.3; Motor Type: 2-Speed Belt; Volts: 460V; Nom. CFM: 4,000; Min. Circuit Amps: 22.0; Width: 93-3/4"; Height: 54-1/4"; Depth: 60-3/8"; Wt. Lbs.: 1,226;
Brand: Daikin Mfg #: DBH1204V000001S

Single Packaged Heat Pump 12.5 IEER/10.6 EER,Three-Phase, 12-1/2 Ton, R410A B65-352
Single Packaged Heat Pump 12.5 IEER/10.6 EER,Three-Phase, 12-1/2 Ton, R410A
Nom. Tons: 12-1/2; BtuH Cooling: 140,000; BtuH Heating Input: 140,000; EER: 10.6; HSPF: 8.0; COP: 3.2; Motor Type: 2-Speed Belt; Volts: 460V; Nom. CFM: 4,250; Min. Circuit Amps: 30.9; Width: 93-3/4"; Height: 58-3/5"; Depth: 60-3/8"; Wt. Lbs.: 1,314;
Brand: Daikin Mfg #: DBH1504V000001S

Single Packaged Heat Pump 12.5 IEER/11.0 EER,Three-Phase, 10 Ton, R410A B64-398
Single Packaged Heat Pump 12.5 IEER/11.0 EER,Three-Phase, 10 Ton, R410A
Nom. Tons: 10; BtuH Cooling: 112,000; BtuH Heating Input: 106,000; EER: 11.0; HSPF: 8.0; COP: 3.3; Motor Type: 2-Speed Belt; Volts: 208/230V; Nom. CFM: 4,000; Min. Circuit Amps: 48.8; Width: 93-3/4"; Height: 54-1/4"; Depth: 60-3/8"; Wt. Lbs.: 1,216;
Brand: Daikin Mfg #: DBH1203V000001S

Single Packaged Heat Pump 14 SEER/11.5 EER, Three-Phase, 3 Ton, R410A B62-909
Single Packaged Heat Pump 14 SEER/11.5 EER, Three-Phase, 3 Ton, R410A
Nom. Tons: 3; BtuH Cooling: 35,000; BtuH Heating Input: 34,200; EER: 11.5; HSPF: 8.0; COP: 2.34; Motor Type: Belt Drive; Volts: 460; Nom. CFM: 1,170; Min. Circuit Amps: 9.39; Width: 74"; Height: 39-7/8"; Depth: 48-5/16"; Wt. Lbs.: 610;
Brand: Daikin Mfg #: DBH0364B000001S

Single Packaged Heat Pump 14 SEER/11.5 EER, Three-Phase, 3 Ton, R410A B62-903
Single Packaged Heat Pump 14 SEER/11.5 EER, Three-Phase, 3 Ton, R410A
Nom. Tons: 3; BtuH Cooling: 35,000; BtuH Heating Input: 34,200; EER: 11.5; HSPF: 8.0; COP: 2.34; Motor Type: Direct Drive; Volts: 208/230; Nom. CFM: 1,170; Min. Circuit Amps: 19.70; Width: 74"; Height: 39-7/8"; Depth: 48-5/16"; Wt. Lbs.: 560;
Brand: Daikin Mfg #: DBH0363D000001S

Single Packaged Heat Pump 12.5 IEER/11.2 EER,Three-Phase, 7-1/2 Ton, R410A B64-389
Single Packaged Heat Pump 12.5 IEER/11.2 EER,Three-Phase, 7-1/2 Ton, R410A
Nom. Tons: 7-1/2; BtuH Cooling: 88,000; BtuH Heating Input: 80,000; EER: 11.2; HSPF: 8.0; COP: 3.3; Motor Type: 2-Speed Belt; Volts: 208/230V; Nom. CFM: 2,850; Min. Circuit Amps: 42.6; Width: 93-3/4"; Height: 54-1/4"; Depth: 60-3/8"; Wt. Lbs.: 1,152;
Brand: Daikin Mfg #: DBH0903V000001S

Single Packaged Heat Pump 15 SEER/13.0 EER, Three-Phase, 3 Ton, R410A B61-138
Single Packaged Heat Pump 15 SEER/13.0 EER, Three-Phase, 3 Ton, R410A
Nom. Tons: 3; BtuH Cooling: 35,000; BtuH Heating Input: 32,800; EER: 13.0; HSPF: 8.0; COP: 3.6; Motor Type: Direct Drive; Volts: 208/230; Nom. CFM: 1,200; Min. Circuit Amps: 16.5; Width: 74-61/1000"; Height: 38-21/25"; Depth: 48-49/250"; Wt. Lbs.: 520;
Brand: Daikin Mfg #: DTH036XXX3DXXX

Single Packaged Heat Pump 15 SEER/12.5 EER, Three-Phase, 4 Ton, R410A B61-139
Single Packaged Heat Pump 15 SEER/12.5 EER, Three-Phase, 4 Ton, R410A
Nom. Tons: 4; BtuH Cooling: 47,000; BtuH Heating Input: 44,000; EER: 12.5; HSPF: 8.0; COP: 3.8; Motor Type: Direct Drive; Volts: 208/230; Nom. CFM: 1,600; Min. Circuit Amps: 24.7; Width: 74-61/1000"; Height: 38-21/25"; Depth: 48-49/250"; Wt. Lbs.: 549;
Brand: Daikin Mfg #: DTH048XXX3DXXX

Single Packaged Heat Pump 15 SEER/12.5 EER, Three-Phase, 5 Ton, R410A B61-140
Single Packaged Heat Pump 15 SEER/12.5 EER, Three-Phase, 5 Ton, R410A
Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 55,000; EER: 12.5; HSPF: 8.2; COP: 3.6; Motor Type: Direct Drive; Volts: 208/230; Nom. CFM: 2,000; Min. Circuit Amps: 29.1; Width: 74-61/1000"; Height: 42-21/25"; Depth: 48-49/250"; Wt. Lbs.: 583;
Brand: Daikin Mfg #: DTH060XXX3DXXX

Single Packaged Heat Pump Up tp 17.0 IEER/12.6 EER Three-Phase 5 Ton, R410A, Direct Drive B64-762
Single Packaged Heat Pump Up tp 17.0 IEER/12.6 EER Three-Phase 5 Ton, R410A, Direct Drive
Nom. Tons: 5; BtuH Cooling: 59,000; EER: 12.1; HSPF: 8.2; COP: 3.9; Motor Type: Direct Drive; Volts: 208/230; Nom. CFM: 1,850; Min. Circuit Amps: 30.7; Width: 74"; Height: 43-1/2"; Depth: 48-5/16"; Wt. Lbs.: 630;
Brand: Daikin Mfg #: DRH0603D000001S

Single Packaged Heat Pump Up tp 17.0 IEER/12.6 EER Three-Phase 4 Ton, R410A, Direct Drive B64-761
Single Packaged Heat Pump Up tp 17.0 IEER/12.6 EER Three-Phase 4 Ton, R410A, Direct Drive
Nom. Tons: 4; BtuH Cooling: 48,000; EER: 12.6; HSPF: 8.2; COP: 4.0; Motor Type: Direct Drive; Volts: 208/230; Nom. CFM: 1,600; Min. Circuit Amps: 27.9; Width: 74"; Height: 43-1/2"; Depth: 48-5/16"; Wt. Lbs.: 621;
Brand: Daikin Mfg #: DRH0483D000001S

Single Packaged Heat Pump Up tp 17.0 IEER/12.6 EER Three-Phase 3 Ton, R410A, Direct Drive B64-760
Single Packaged Heat Pump Up tp 17.0 IEER/12.6 EER Three-Phase 3 Ton, R410A, Direct Drive
Nom. Tons: 3; BtuH Cooling: 36,000; EER: 12.6; HSPF: 8.2; COP: 3.6; Motor Type: Direct Drive; Volts: 208/230; Nom. CFM: 1,200; Min. Circuit Amps: 21.2; Width: 74"; Height: 43-1/2"; Depth: 48-5/16"; Wt. Lbs.: 595;
Brand: Daikin Mfg #: DRH0363D000001S
FTL Finance
Powered by Site Search powered by SLI Systems
Select products to compare.
Compare