35 Results

14, 5, 4, Coleman, Residential Unitary, HVAC Equipment

Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 5 Ton, R410A, 81% AFUE B64-202
Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 5 Ton, R410A, 81% AFUE
SEER: 14; EER: 11.2; Nom. Tons: 5; BtuH Cooling: 56,500; BtuH Heating Input: 100,000; BtuH Heating Output: 80,000; Volts: 208/230V; Phase: Single; Nom. CFM: 1,810; Min. Circuit Amps: 36.5; Refrigerant: R410A; Width: 35-3/4"; Height: 50"; Depth: 51-1/4"; Wt. Lbs.: 475;
Brand: Coleman Mfg #: PCG4B601002X4

Single Packaged Heat Pump 14 SEER, 5 Ton, Single-Phase, R410A B64-163
Single Packaged Heat Pump 14 SEER, 5 Ton, Single-Phase, R410A
SEER: 14; EER: 11.6; Nom. Tons: 5; BtuH Cooling: 59,500; BtuH Heating Input: 56,500; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 3.6; Nom. CFM: 1,850; Min. Circuit Amps: 36.5; Refrigerant: R410A; Width: 45-3/4"; Height: 55"; Depth: 51-1/4"; Wt. Lbs.: 485;
Brand: Coleman Mfg #: PHE4B6024

Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 5 Ton, R410A, 81% AFUE B64-203
Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 5 Ton, R410A, 81% AFUE
SEER: 14; EER: 11.2; Nom. Tons: 5; BtuH Cooling: 56,500; BtuH Heating Input: 125,000; BtuH Heating Output: 100,000; Volts: 208/230V; Phase: Single; Nom. CFM: 1,810; Min. Circuit Amps: 36.5; Refrigerant: R410A; Width: 35-3/4"; Height: 50"; Depth: 51-1/4"; Wt. Lbs.: 479;
Brand: Coleman Mfg #: PCG4B601252X4

Single Packaged Heat Pump 14 SEER, 4 Ton, Single-Phase, R410A B64-162
Single Packaged Heat Pump 14 SEER, 4 Ton, Single-Phase, R410A
SEER: 14; EER: 11.6; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 46,500; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 3.7; Nom. CFM: 1,500; Min. Circuit Amps: 30.0; Refrigerant: R410A; Width: 45-3/4"; Height: 53"; Depth: 51-1/4"; Wt. Lbs.: 479;
Brand: Coleman Mfg #: PHE4B4824

Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 4 Ton, R410A, 81% AFUE B64-199
Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 4 Ton, R410A, 81% AFUE
SEER: 14; EER: 11.2; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 100,000; BtuH Heating Output: 80,000; Volts: 208/230V; Phase: Single; Nom. CFM: 1,560; Min. Circuit Amps: 30.0; Refrigerant: R410A; Width: 35-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 456;
Brand: Coleman Mfg #: PCG4B481002X4

Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 4 Ton, R410A, 81% AFUE B64-200
Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 4 Ton, R410A, 81% AFUE
SEER: 14; EER: 11.2; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 125,000; BtuH Heating Output: 100,000; Volts: 208/230V; Phase: Single; Nom. CFM: 1,560; Min. Circuit Amps: 30.0; Refrigerant: R410A; Width: 35-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 460;
Brand: Coleman Mfg #: PCG4B481252X4

Single Packaged Air Conditioner 14 SEER, Single-Phase, 5 Ton, R410A B64-147
Single Packaged Air Conditioner 14 SEER, Single-Phase, 5 Ton, R410A
SEER: 14; EER: 11.2; Nom. Tons: 5; BtuH Cooling: 56,500; Volts: 208/230; Phase: Single; Motor Type: ECM; Nom. CFM: 1,810; Min. Circuit Amps: 36.5; Max. Fuse Size: 50; Refrigerant: R410A; Width: 45-3/4"; Height: 50"; Depth: 51-1/4"; Wt. Lbs.: 450;
Brand: Coleman Mfg #: PCE4B6024

Single Packaged Air Conditioner 14 SEER, Single-Phase, 4 Ton, R410A B64-146
Single Packaged Air Conditioner 14 SEER, Single-Phase, 4 Ton, R410A
SEER: 14; EER: 11.2; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Nom. CFM: 1,560; Min. Circuit Amps: 30.0; Max. Fuse Size: 45; Refrigerant: R410A; Width: 45-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 431;
Brand: Coleman Mfg #: PCE4B4824

Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 4 Ton, R410A, 81% AFUE B64-198
Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 4 Ton, R410A, 81% AFUE
SEER: 14; EER: 11.2; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 65,000; BtuH Heating Output: 52,000; Volts: 208/230V; Phase: Single; Nom. CFM: 1,560; Min. Circuit Amps: 30.0; Refrigerant: R410A; Width: 35-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 450;
Brand: Coleman Mfg #: PCG4B480652X4

Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 5 Ton, R410A, 81% AFUE B64-201
Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 5 Ton, R410A, 81% AFUE
SEER: 14; EER: 11.2; Nom. Tons: 5; BtuH Cooling: 56,500; BtuH Heating Input: 65,000; BtuH Heating Output: 52,000; Volts: 208/230V; Phase: Single; Nom. CFM: 1,810; Min. Circuit Amps: 36.5; Refrigerant: R410A; Width: 35-3/4"; Height: 50"; Depth: 51-1/4"; Wt. Lbs.: 469;
Brand: Coleman Mfg #: PCG4B600652X4

Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 4 Ton, R410A, Southeast & Northern Region Only B77-430
Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 4 Ton, R410A, Southeast & Northern Region Only
SEER: 14; EER: 11.7; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 25.7; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/4"; Height: 33-1/4"; Depth: 31-3/4"; Wt. Lbs.: 200; OEM TXV: B19-659; OEM…
Brand: Coleman Mfg #: TC4B4821S

Heat Pump LX Series, 14 SEER, Single-Phase, 4 Ton, R410A B60-661
Heat Pump LX Series, 14 SEER, Single-Phase, 4 Ton, R410A
SEER: 14; EER: 12.25; Nom. Tons: 4; BtuH Cooling: 46,500; BtuH Heating Input: 48,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.2; COP: 3.66; Min. Circuit Amps: 30.8; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 38"; Height: 39-1/2"; Depth:…
Brand: Coleman Mfg #: TH4B4822S

Heat Pump LX Series, 14 SEER, Single-Phase, 5 Ton, R410A B60-662
Heat Pump LX Series, 14 SEER, Single-Phase, 5 Ton, R410A
SEER: 14; EER: 12; Nom. Tons: 5; BtuH Cooling: 55,500; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.2; COP: 3.88; Min. Circuit Amps: 31.7; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 38"; Height: 42-3/4"; Depth:…
Brand: Coleman Mfg #: TH4B6022S

Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 5 Ton, R410A, Southeast & Northern Region Only B77-431
Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 5 Ton, R410A, Southeast & Northern Region Only
SEER: 14; EER: 11.7; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 31.7; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 38"; Height: 36-1/4"; Depth: 34-1/4"; Wt. Lbs.: 205; OEM TXV: B19-660; OEM…
Brand: Coleman Mfg #: TC4B6021S

Heat Pump LX Series, 14 SEER, Single-Phase, 5 Ton, R410A B62-868
Heat Pump LX Series, 14 SEER, Single-Phase, 5 Ton, R410A
SEER: 14; EER: 12.0; Nom. Tons: 5; BtuH Cooling: 56,500; BtuH Heating Input: 56,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 9.0; COP: 3.70; Min. Circuit Amps: 29.1; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 38"; Height: 42-3/4";…
Brand: Coleman Mfg #: TE4B6021S

Heat Pump LX Series, 14 SEER, Single-Phase, 4 Ton, R410A B62-867
Heat Pump LX Series, 14 SEER, Single-Phase, 4 Ton, R410A
SEER: 14; EER: 12.0; Nom. Tons: 4; BtuH Cooling: 46,500; BtuH Heating Input: 45,500; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 9.0; COP: 3.58; Min. Circuit Amps: 24.5; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 38"; Height: 39-1/2"; Depth:…
Brand: Coleman Mfg #: TE4B4821S

Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 4 Ton, R410A, Southwest Region Only B77-437
Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 4 Ton, R410A, Southwest Region Only
SEER: 14; EER: 11.7; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 25.7; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/4"; Height: 33-1/4"; Depth: 31-3/4"; Wt. Lbs.: 200; OEM TXV: B19-659; OEM…
Brand: Coleman Mfg #: TW4B4821S

Air Conditioning Condensing Unit Horizontal Discharge, 14 SEER, Single-Phase, 4 Ton, R410A B60-176
Air Conditioning Condensing Unit Horizontal Discharge, 14 SEER, Single-Phase, 4 Ton, R410A
SEER: 14; EER: 12.2; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 24.6; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 45"; Height: 43-1/4"; Depth: 20"; Wt. Lbs.: 240; OEM TXV: B20-259; OEM TXV for…
Brand: Coleman Mfg #: TCHE48S41S1

Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 5 Ton, R410A, Southwest Region Only B77-438
Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 5 Ton, R410A, Southwest Region Only
SEER: 14; EER: 11.7; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 31.7; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 38"; Height: 36-1/4"; Depth: 31-3/4"; Wt. Lbs.: 205; OEM TXV: B19-660; OEM…
Brand: Coleman Mfg #: TW4B6021S

Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 4 Ton, R410A, 81% AFUE, LOWNOx B63-657
Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 4 Ton, R410A, 81% AFUE, LOWNOx
SEER: 14; EER: 11.2; Nom. Tons: 4; BtuH Cooling: 47,000; BtuH Heating Input: 65,000; BtuH Heating Output: 53,000; Volts: 208/230V; Phase: Single; Nom. CFM: 1,600; Min. Circuit Amps: 30.0; Refrigerant: R410A; Width: 45-3/4; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 460;
Brand: Coleman Mfg #: PCG4B480652L1

Packaged Heat Pump 14 SEER, Single-Phase, Single-Stage, 5 Ton, R410A B64-407
Packaged Heat Pump 14 SEER, Single-Phase, Single-Stage, 5 Ton, R410A
SEER: 14; EER: 11.6; Nom. Tons: 5; BtuH Cooling: 59,500; BtuH Heating Input: 125,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 4.96; Nom. CFM: 1,850; Min. Circuit Amps: 36.5; Refrigerant: R410A; Width: 45-3/4"; Height: 55"; Depth: 51-1/4"; Wt. Lbs.: 550;
Brand: Coleman Mfg #: PHG4B601252X4

Packaged Heat Pump 14 SEER, Single-Phase, Single-Stage, 4 Ton, R410A B64-405
Packaged Heat Pump 14 SEER, Single-Phase, Single-Stage, 4 Ton, R410A
SEER: 14; EER: 11.6; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 100,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 5.02; Nom. CFM: 1,500; Min. Circuit Amps: 30.0; Refrigerant: R410A; Width: 45-3/4"; Height: 53"; Depth: 51-1/4"; Wt. Lbs.: 542;
Brand: Coleman Mfg #: PHG4B481002X4

Packaged Heat Pump 14 SEER, Single-Phase, Single-Stage, 4 Ton, R410A B64-406
Packaged Heat Pump 14 SEER, Single-Phase, Single-Stage, 4 Ton, R410A
SEER: 14; EER: 11.6; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 125,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 5.02; Nom. CFM: 1,500; Min. Circuit Amps: 30.0; Refrigerant: R410A; Width: 45-3/4"; Height: 53"; Depth: 51-1/4"; Wt. Lbs.: 544;
Brand: Coleman Mfg #: PHG4B481252X4

Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 5 Ton, R410A, 81% AFUE B76-981
Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 5 Ton, R410A, 81% AFUE
SEER: 14; Nom. Tons: 5; BtuH Cooling: 52,500; BtuH Heating Input: 125,000; BtuH Heating Output: 100,000; Volts: 208/230V; Phase: Single; Nom. CFM: 1,600; Min. Circuit Amps: 42.6; Refrigerant: R410A; Width: 45-3/4"; Height: 51"; Depth: 51"; Wt. Lbs.: 548;
Brand: Coleman Mfg #: PCG4B601252X2