79 Results

16, Single Packaged Units, Residential Unitary, HVAC Equipment

Single Packaged Gas/Heat Air Conditioner LX Series, 16 SEER, Single-Phase, 3 Ton, R410A, 81% AFUE B64-226
Single Packaged Gas/Heat Air Conditioner LX Series, 16 SEER, Single-Phase, 3 Ton, R410A, 81% AFUE
SEER: 16; EER: 12.0; Nom. Tons: 3; BtuH Cooling: 35,800; BtuH Heating Input: 75,000; BtuH Heating Output: 60,000; Volts: 208/230; Phase: Single; Nom. CFM: 1,200; Min. Circuit Amps: 23.2; Refrigerant: R410A; Width: 35-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 466;
Brand: Coleman Mfg #: PCG6A360752X4

Single Packaged Gas/Heat Air Conditioner LX Series, 16 SEER, Single-Phase, 4 Ton, R410A, 81% AFUE B64-228
Single Packaged Gas/Heat Air Conditioner LX Series, 16 SEER, Single-Phase, 4 Ton, R410A, 81% AFUE
SEER: 16; EER: 12.0; Nom. Tons: 4; BtuH Cooling: 46,000; BtuH Heating Input: 100,000; BtuH Heating Output: 80,000; Volts: 208/230; Phase: Single; Nom. CFM: 1,550; Min. Circuit Amps: 28.4; Refrigerant: R410A; Width: 45-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 528;
Brand: Coleman Mfg #: PCG6B481002X4

Single Packaged Gas/Heat Air Conditioner LX Series, 16 SEER, Single-Phase, 2 Ton, R410A, 81% AFUE B64-224
Single Packaged Gas/Heat Air Conditioner LX Series, 16 SEER, Single-Phase, 2 Ton, R410A, 81% AFUE
SEER: 16; EER: 12.5; Nom. Tons: 2; BtuH Cooling: 24,000; BtuH Heating Input: 50,000; BtuH Heating Output: 40,000; Volts: 208/230; Phase: Single; Nom. CFM: 750; Min. Circuit Amps: 16.1; Refrigerant: R410A; Width: 35-3/4"; Height: 44"; Depth: 51-1/4"; Wt. Lbs.: 372;
Brand: Coleman Mfg #: PCG6A240502X4

Single Packaged Gas/Heat Air Conditioner LX Series, 16 SEER, Single-Phase, 5 Ton, R410A, 81% AFUE B64-232
Single Packaged Gas/Heat Air Conditioner LX Series, 16 SEER, Single-Phase, 5 Ton, R410A, 81% AFUE
SEER: 16; EER: 12.0; Nom. Tons: 5; BtuH Cooling: 59,000; BtuH Heating Input: 125,000; BtuH Heating Output: 101,000; Volts: 208/230; Phase: Single; Nom. CFM: 1,825; Min. Circuit Amps: 38.0; Refrigerant: R410A; Width: 45-3/4"; Height: 50"; Depth: 51-1/4"; Wt. Lbs.: 548;
Brand: Coleman Mfg #: PCG6B601252X4

Single Packaged Gas/Heat Air Conditioner LX Series, 16 SEER, Single-Phase, 4 Ton, R410A, 81% AFUE B64-227
Single Packaged Gas/Heat Air Conditioner LX Series, 16 SEER, Single-Phase, 4 Ton, R410A, 81% AFUE
SEER: 16; EER: 12.0; Nom. Tons: 4; BtuH Cooling: 46,000; BtuH Heating Input: 65,000; BtuH Heating Output: 52,000; Volts: 208/230; Phase: Single; Nom. CFM: 1,550; Min. Circuit Amps: 28.4; Refrigerant: R410A; Width: 45-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 520;
Brand: Coleman Mfg #: PCG6B480652X4

Single Packaged Gas/Heat Air Conditioner LX Series, 16 SEER, Single-Phase, 2 Ton, R410A, 81% AFUE B64-225
Single Packaged Gas/Heat Air Conditioner LX Series, 16 SEER, Single-Phase, 2 Ton, R410A, 81% AFUE
SEER: 16; EER: 12.5; Nom. Tons: 2; BtuH Cooling: 24,000; BtuH Heating Input: 75,000; BtuH Heating Output: 60,000; Volts: 208/230; Phase: Single; Nom. CFM: 750; Min. Circuit Amps: 16.1; Refrigerant: R410A; Width: 35-3/4"; Height: 44"; Depth: 51-1/4"; Wt. Lbs.: 382;
Brand: Coleman Mfg #: PCG6A240752X4

Single Packaged Gas/Heat Air Conditioner LX Series, 16 SEER, Single-Phase, 5 Ton, R410A, 81% AFUE B64-231
Single Packaged Gas/Heat Air Conditioner LX Series, 16 SEER, Single-Phase, 5 Ton, R410A, 81% AFUE
SEER: 16; EER: 12.0; Nom. Tons: 5; BtuH Cooling: 59,000; BtuH Heating Input: 100,000; BtuH Heating Output: 80,000; Volts: 208/230; Phase: Single; Nom. CFM: 1,825; Min. Circuit Amps: 38.0; Refrigerant: R410A; Width: 45-3/4"; Height: 50"; Depth: 51-1/4"; Wt. Lbs.: 541;
Brand: Coleman Mfg #: PCG6B601002X4

Single Packaged Gas/Heat Air Conditioner LX Series, 16 SEER, Single-Phase, 4 Ton, R410A, 81% AFUE B64-229
Single Packaged Gas/Heat Air Conditioner LX Series, 16 SEER, Single-Phase, 4 Ton, R410A, 81% AFUE
SEER: 16; EER: 12.0; Nom. Tons: 4; BtuH Cooling: 46,000; BtuH Heating Input: 125,000; BtuH Heating Output: 101,000; Volts: 208/230; Phase: Single; Nom. CFM: 1,550; Min. Circuit Amps: 28.4; Refrigerant: R410A; Width: 45-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 533;
Brand: Coleman Mfg #: PCG6B481252X4

Single Packaged Gas/Heat Air Conditioner LX Series, 16 SEER, Single-Phase, 5 Ton, R410A, 81% AFUE B64-230
Single Packaged Gas/Heat Air Conditioner LX Series, 16 SEER, Single-Phase, 5 Ton, R410A, 81% AFUE
SEER: 16; EER: 12.0; Nom. Tons: 5; BtuH Cooling: 59,000; BtuH Heating Input: 65,000; BtuH Heating Output: 52,000; Volts: 208/230; Phase: Single; Nom. CFM: 1,825; Min. Circuit Amps: 38.0; Refrigerant: R410A; Width: 45-3/4"; Height: 50"; Depth: 51-1/4"; Wt. Lbs.: 537;
Brand: Coleman Mfg #: PCG6B600652X4

Single Packaged Air Conditioner 16 SEER, Single-Phase, 3 Ton, R410A B64-149
Single Packaged Air Conditioner 16 SEER, Single-Phase, 3 Ton, R410A
SEER: 16; EER: 12.5; Nom. Tons: 3; BtuH Cooling: 36,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Nom. CFM: 1,275; Min. Circuit Amps: 23.2; Max. Fuse Size: 35; Refrigerant: R410A; Width: 35-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 461;
Brand: Coleman Mfg #: PCE6A3624

Single Packaged Heat Pump 16 SEER, Single-Phase, 2-1/2 Ton, R410A, Multi-Position B77-257
Single Packaged Heat Pump 16 SEER, Single-Phase, 2-1/2 Ton, R410A, Multi-Position
SEER: 16; EER: 12.0; Nom. Tons: 2-1/2; BtuH Cooling: 29,000; BtuH Heating Input: 28,400; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 3.5; Nom. CFM: 1,050; Min. Circuit Amps: 22.2; Refrigerant: R410A; Width: 47"; Height: 34-3/4"; Depth: 51"; Wt. Lbs.: 385;
Brand: Goodman Mfg #: GPH1630M41

Single Packaged Air Conditioner 16 SEER, Single-Phase, 5 Ton, R410A B64-151
Single Packaged Air Conditioner 16 SEER, Single-Phase, 5 Ton, R410A
SEER: 16; EER: 12.0; Nom. Tons: 5; BtuH Cooling: 59,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Nom. CFM: 1,825; Min. Circuit Amps: 38.0; Max. Fuse Size: 60; Refrigerant: R410A; Width: 45-3/4"; Height: 50"; Depth: 51-1/4"; Wt. Lbs.: 500;
Brand: Coleman Mfg #: PCE6B6024

Single Packaged Air Conditioner 16 SEER, Single-Phase, 4 Ton, R410A B64-150
Single Packaged Air Conditioner 16 SEER, Single-Phase, 4 Ton, R410A
SEER: 16; EER: 12.0; Nom. Tons: 4; BtuH Cooling: 46,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Nom. CFM: 1,550; Min. Circuit Amps: 28.4; Max. Fuse Size: 45; Refrigerant: R410A; Width: 45-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 483;
Brand: Coleman Mfg #: PCE6B4824

Single Packaged Air Conditioner 16 SEER, Single-Phase, 2 Ton, R410A B64-148
Single Packaged Air Conditioner 16 SEER, Single-Phase, 2 Ton, R410A
SEER: 16; EER: 12.5; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Nom. CFM: 750; Min. Circuit Amps: 17.3; Max. Fuse Size: 25; Refrigerant: R410A; Width: 35-3/4"; Height: 44"; Depth: 51-1/4"; Wt. Lbs.: 343;
Brand: Coleman Mfg #: PCE6A2424

Single Packaged Heat Pump 16 SEER, Single-Phase, 2 Ton, R410A, Multi-Position B77-256
Single Packaged Heat Pump 16 SEER, Single-Phase, 2 Ton, R410A, Multi-Position
SEER: 16; EER: 12.5; Nom. Tons: 2; BtuH Cooling: 24,000; BtuH Heating Input: 22,800; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 3.6; Nom. CFM: 850; Min. Circuit Amps: 20.4; Refrigerant: R410A; Width: 47"; Height: 34-3/4"; Depth: 51"; Wt. Lbs.: 376;
Brand: Goodman Mfg #: GPH1624M41

Single Packaged Heat Pump 16 SEER, 4 Ton, Single-Phase, R410A B79-387
Single Packaged Heat Pump 16 SEER, 4 Ton, Single-Phase, R410A
SEER: 16; EER: 12.5; Nom. Tons: 4; BtuH Cooling: 47,500; BtuH Heating Input: 47,400; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.2; COP: 3.6; Nom. CFM: 1,600; Min. Circuit Amps: 33.6; Refrigerant: R410A; Width: 45-3/4"; Height: 53"; Depth: 51-1/4"; Wt. Lbs.: 496;
Brand: Coleman Mfg #: PHE6B4821

Single Packaged Heat Pump 16 SEER, 2 Ton, Single-Phase, R410A B79-383
Single Packaged Heat Pump 16 SEER, 2 Ton, Single-Phase, R410A
SEER: 16; EER: 12.5; Nom. Tons: 2; BtuH Cooling: 23,500; BtuH Heating Input: 22,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.2; COP: 3.7; Nom. CFM: 800; Min. Circuit Amps: 19.1; Refrigerant: R410A; Width: 35-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 377;
Brand: Coleman Mfg #: PHE6A2421

Single Packaged Heat Pump 16 SEER, 5 Ton, Single-Phase, R410A B79-388
Single Packaged Heat Pump 16 SEER, 5 Ton, Single-Phase, R410A
SEER: 16; EER: 12.5; Nom. Tons: 5; BtuH Cooling: 57,500; BtuH Heating Input: 57,200; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.2; COP: 3.6; Nom. CFM: 1,800; Min. Circuit Amps: 42.3; Refrigerant: R410A; Width: 45-3/4"; Height: 55"; Depth: 51-1/4"; Wt. Lbs.: 523;
Brand: Coleman Mfg #: PHE6B6021

Single Packaged Heat Pump 16 SEER, Single-Phase, 4 Ton, R410A, Multi-Position B77-260
Single Packaged Heat Pump 16 SEER, Single-Phase, 4 Ton, R410A, Multi-Position
SEER: 16; EER: 12.0; Nom. Tons: 4; BtuH Cooling: 47,000; BtuH Heating Input: 45,500; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.2; COP: 3.7; Nom. CFM: 1,600; Min. Circuit Amps: 33.7; Refrigerant: R410A; Width: 47"; Height: 42-1/4"; Depth: 51"; Wt. Lbs.: 490;
Brand: Goodman Mfg #: GPH1648M41

Single Packaged Gas/Electric Air Conditioner 16 SEER, Single-Phase, 3-1/2 Ton, 81% AFUE, R410A, Multi-Position B75-675
Single Packaged Gas/Electric Air Conditioner 16 SEER, Single-Phase, 3-1/2 Ton, 81% AFUE, R410A, Multi-Position
SEER: 16; EER: 12.0; Nom. Tons: 3-1/2; BtuH Cooling: 40,000; BtuH Heating Input: 100,000; BtuH Heating Output: 78,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Nom. CFM: 1,250; Min. Circuit Amps: 29.2; Refrigerant: R410A; Width: 47"; Height: 42-3/4"; Depth: 51"; Wt. Lbs.: 495;
Brand: Goodman Mfg #: GPG1642100M41

Single Packaged Heat Pump 16 SEER, Single-Phase, 3-1/2 Ton, R410A, Multi-Position B77-259
Single Packaged Heat Pump 16 SEER, Single-Phase, 3-1/2 Ton, R410A, Multi-Position
SEER: 16; EER: 12.0; Nom. Tons: 3-1/2; BtuH Cooling: 41,000; BtuH Heating Input: 38,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.2; COP: 3.6; Nom. CFM: 1,300; Min. Circuit Amps: 29.6; Refrigerant: R410A; Width: 47"; Height: 42-1/4"; Depth: 51"; Wt. Lbs.: 492;
Brand: Goodman Mfg #: GPH1642M41

Single Packaged Heat Pump 16 SEER, Single-Phase, 3-1/2 Ton, R410A, Horizontal B76-934
Single Packaged Heat Pump 16 SEER, Single-Phase, 3-1/2 Ton, R410A, Horizontal
SEER: 16; EER: 12; Nom. Tons: 3-1/2; BtuH Cooling: 40,500; BtuH Heating Input: 37,600; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 3.8; Nom. CFM: 1,300; Min. Circuit Amps: 28.0; Refrigerant: R410A; Width: 66"; Height: 35"; Depth: 34"; Wt. Lbs.: 375;
Brand: Goodman Mfg #: GPH1642H41

Single Packaged Heat Pump 16 SEER, Single-Phase, 2-1/2 Ton, R410A, Horizontal B76-932
Single Packaged Heat Pump 16 SEER, Single-Phase, 2-1/2 Ton, R410A, Horizontal
SEER: 16; EER: 12.5; Nom. Tons: 2-1/2; BtuH Cooling: 28,400; BtuH Heating Input: 27,600; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 3.8; Nom. CFM: 1,050; Min. Circuit Amps: 23.0; Refrigerant: R410A; Width: 66"; Height: 30"; Depth: 34"; Wt. Lbs.: 315;
Brand: Goodman Mfg #: GPH1630H41

Single Packaged Heat Pump 16 SEER, Single-Phase, 3 Ton, R410A, Horizontal B76-933
Single Packaged Heat Pump 16 SEER, Single-Phase, 3 Ton, R410A, Horizontal
SEER: 16; EER: 13; Nom. Tons: 3; BtuH Cooling: 36,000; BtuH Heating Input: 32,200; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 3.8; Nom. CFM: 1,200; Min. Circuit Amps: 27.0; Refrigerant: R410A; Width: 66"; Height: 35"; Depth: 34"; Wt. Lbs.: 375;
Brand: Goodman Mfg #: GPH1636H41
FTL Finance
Powered by Site Search powered by SLI Systems
Select products to compare.
Compare