33 Results

2, 11 to 11.9, Residential Unitary, HVAC Equipment

Heat Pump 15 SEER, Single-Phase, 2 Ton, R410A B65-707
Heat Pump 15 SEER, Single-Phase, 2 Ton, R410A
SEER: 15; EER: 11.2; Nom. Tons: 2; BtuH Cooling: 24,000; BtuH Heating Input: 24,000; Volts: 208/230; Phase: Single; HSPF: 9.0; Min. Circuit Amps: 22.9; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 28"; Height: 24-15/16"; Depth: 28"; Wt. Lbs.: 126;
Brand: Bosch Mfg #: BOVA24HDN1M15G

Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 2 Ton, R410A, 81% AFUE B64-190
Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 2 Ton, R410A, 81% AFUE
SEER: 14; EER: 11.0; Nom. Tons: 2; BtuH Cooling: 23,600; BtuH Heating Input: 75,000; BtuH Heating Output: 60,000; Volts: 208/230V; Phase: Single; Nom. CFM: 775; Min. Circuit Amps: 18.1; Refrigerant: R410A; Width: 35-3/4"; Height: 44"; Depth: 51-1/4"; Wt. Lbs.: 336;
Brand: Coleman Mfg #: PCG4A240752X4

Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 2 Ton, R410A B62-069
Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 2 Ton, R410A
SEER: 13; EER: 11.0; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 11.4; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 24"; Height: 26-3/4"; Depth: 24"; Wt. Lbs.: 130; OEM TXV: B20-469; OEM TXV for…
Brand: Coleman Mfg #: TC3B2423S

Single Packaged Heat Pump 14 SEER, 2 Ton, Single-Phase, R410A B64-158
Single Packaged Heat Pump 14 SEER, 2 Ton, Single-Phase, R410A
SEER: 14; EER: 11.6; Nom. Tons: 2; BtuH Cooling: 25,000; BtuH Heating Input: 23,600; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 3.7; Nom. CFM: 780; Min. Circuit Amps: 18.6; Refrigerant: R410A; Width: 35-3/4"; Height: 44"; Depth: 51-1/4"; Wt. Lbs.: 330;
Brand: Coleman Mfg #: PHE4A2424

Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 2 Ton, R410A, 81% AFUE B64-189
Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 2 Ton, R410A, 81% AFUE
SEER: 14; EER: 11.0; Nom. Tons: 2; BtuH Cooling: 23,600; BtuH Heating Input: 50,000; BtuH Heating Output: 40,000; Volts: 208/230V; Phase: Single; Nom. CFM: 775; Min. Circuit Amps: 16.9; Refrigerant: R410A; Width: 35-3/4"; Height: 44"; Depth: 51-1/4"; Wt. Lbs.: 316;
Brand: Coleman Mfg #: PCG4A240502X4

Single Packaged Air Conditioner 14 SEER, Single-Phase, 2 Ton, R410A B64-142
Single Packaged Air Conditioner 14 SEER, Single-Phase, 2 Ton, R410A
SEER: 14; EER: 11.0; Nom. Tons: 2; BtuH Cooling: 23,600; Volts: 208/230; Phase: Single; Motor Type: ECM; Nom. CFM: 775; Min. Circuit Amps: 18.1; Max. Fuse Size: 25; Refrigerant: R410A; Width: 35-3/4"; Height: 44"; Depth: 51-1/4"; Wt. Lbs.: 307;
Brand: Coleman Mfg #: PCE4A2424

Heat Pump 14 SEER, Single-Phase, 2 Ton, R410A B75-914
Heat Pump 14 SEER, Single-Phase, 2 Ton, R410A
SEER: 14; EER: 11.5; Nom. Tons: 2; BtuH Cooling: 24,000; BtuH Heating Input: 24,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.2; COP: 4.39; Min. Circuit Amps: 10.6; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29"; Height: 34-1/2"; Depth:…
Brand: Goodman Mfg #: GSZ140241

Air Conditioning Condensing Unit 13 SEER, Single-Phase, 2 Ton, R410A B61-811
Air Conditioning Condensing Unit 13 SEER, Single-Phase, 2 Ton, R410A
SEER: 13; EER: 11.0; Nom. Tons: 2; BtuH Cooling: 23,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 10.3; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 23"; Height: 27-1/2"; Depth: 23"; Wt. Lbs.: 103; OEM TXV: B18-099;
Brand: Goodman Mfg #: GSX130241

Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 2 Ton, R410A, Southeast & Northern Region Only B61-252
Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 2 Ton, R410A, Southeast & Northern Region Only
SEER: 14; EER: 11.7; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 14.8; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29-1/4"; Height: 26-3/4"; Depth: 29-1/4"; Wt. Lbs.: 135; OEM TXV: B20-469; OEM…
Brand: Coleman Mfg #: TC4B2422S

Air Conditioning Condensing Unit 14 SEER, Single-Phase, 2 Ton, R410A B75-907
Air Conditioning Condensing Unit 14 SEER, Single-Phase, 2 Ton, R410A
SEER: 14; EER: 11.5; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 14.2; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 26"; Height: 27-1/2"; Depth: 26"; Wt. Lbs.: 131; OEM TXV: B18-099;
Brand: Goodman Mfg #: GSX140241

Single Packaged Heat Pump 14 SEER, Single-Phase, 2 Tons, R410A, Multi-Position B76-801
Single Packaged Heat Pump 14 SEER, Single-Phase, 2 Tons, R410A, Multi-Position
SEER: 14; EER: 11; Nom. Tons: 2; BtuH Cooling: 24,000; BtuH Heating Input: 23,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 3.6; Nom. CFM: 850; Min. Circuit Amps: 21.8; Refrigerant: R410A; Width: 47"; Height: 34-3/4"; Depth: 51"; Wt. Lbs.: 380;
Brand: Goodman Mfg #: GPH1424M41

Heat Pump 14 SEER, Single-Phase, 2 Ton, R410A B79-085
Heat Pump 14 SEER, Single-Phase, 2 Ton, R410A
SEER: 14; EER: 11.5; Nom. Tons: 2; BtuH Cooling: 23,200; BtuH Heating Input: 23,200; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.2; COP: 4.73; Min. Circuit Amps: 14.7; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29"; Height: 34-1/2"; Depth:…
Brand: Goodman Mfg #: GSZ140251

Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 2 Ton, R410A, 81% AFUE, LOWNOx B63-655
Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 2 Ton, R410A, 81% AFUE, LOWNOx
SEER: 14; EER: 11.0; Nom. Tons: 2; BtuH Cooling: 23,600; BtuH Heating Input: 50,000; BtuH Heating Output: 41,000; Volts: 208/230V; Phase: Single; Nom. CFM: 800; Min. Circuit Amps: 16.9; Refrigerant: R410A; Width: 35-3/4"; Height: 44"; Depth: 51-1/4"; Wt. Lbs.: 341;
Brand: Coleman Mfg #: PCG4A240502L1

Single Packaged Gas/Electric  Air Conditioner 14 SEER, Single-Phase, 2 Ton, 80% AFUE, R410A, Multi-Position B76-787
Single Packaged Gas/Electric Air Conditioner 14 SEER, Single-Phase, 2 Ton, 80% AFUE, R410A, Multi-Position
SEER: 14; EER: 11.0; Nom. Tons: 2; BtuH Cooling: 23,000; BtuH Heating Input: 60,000; BtuH Heating Output: 48,000; Min. Circuit Amps: 14.6; Refrigerant: R410A; Width: 47"; Height: 32"; Depth: 51"; Wt. Lbs.: 417;
Brand: Goodman Mfg #: GPG1424060M41

Air Conditioning Condensing Unit Horizontal Discharge, 13 SEER, Single-Phase, 2 Ton, R410A B75-666
Air Conditioning Condensing Unit Horizontal Discharge, 13 SEER, Single-Phase, 2 Ton, R410A
SEER: 13; EER: 11.5; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 18.3; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 45"; Height: 37-1/4"; Depth: 20"; Wt. Lbs.: 195; OEM TXV: B19-657; OEM TXV for…
Brand: Coleman Mfg #: TCHD24S41S4

Single Packaged Air Conditioner 14 SEER, Single-Phase, 2 Ton, R410A, Multi-Position B76-780
Single Packaged Air Conditioner 14 SEER, Single-Phase, 2 Ton, R410A, Multi-Position
SEER: 14; EER: 11; Nom. Tons: 2; BtuH Cooling: 23,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Nom. CFM: 800; Min. Circuit Amps: 14.6; Max. Fuse Size: 20; Refrigerant: R410A; Width: 47"; Height: 34-3/4"; Depth: 51"; Wt. Lbs.: 319;
Brand: Goodman Mfg #: GPC1424M41

Single Packaged Gas/Electric  Air Conditioner 14 SEER, Single-Phase, 2 Ton, 80% AFUE, R410A, Multi-Position B76-786
Single Packaged Gas/Electric Air Conditioner 14 SEER, Single-Phase, 2 Ton, 80% AFUE, R410A, Multi-Position
SEER: 14; EER: 11.0; Nom. Tons: 2; BtuH Cooling: 23,000; BtuH Heating Input: 40,000; BtuH Heating Output: 31,000; Min. Circuit Amps: 14.6; Refrigerant: R410A; Width: 47"; Height: 32"; Depth: 51"; Wt. Lbs.: 412;
Brand: Goodman Mfg #: GPG1424040M41

Packaged Heat Pump 14 SEER, Single-Phase, Single-Stage, 2 Ton, R410A B64-400
Packaged Heat Pump 14 SEER, Single-Phase, Single-Stage, 2 Ton, R410A
SEER: 14; EER: 11.6; Nom. Tons: 2; BtuH Cooling: 25,000; BtuH Heating Input: 75,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 4.5; Nom. CFM: 780; Min. Circuit Amps: 17.4; Refrigerant: R410A; Width: 35-3/4"; Height: 44"; Depth: 51-1/4"; Wt. Lbs.: 357;
Brand: Coleman Mfg #: PHG4A240752X4

Heat Pump Up To 15 SEER, Single-Phase, 2 Ton, R410A B76-767
Heat Pump Up To 15 SEER, Single-Phase, 2 Ton, R410A
SEER: 14; EER: 11.5; Nom. Tons: 2; BtuH Cooling: 24,000; BtuH Heating Input: 24,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.2; COP: 4.57; Min. Circuit Amps: 14.6; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29"; Height: 34-1/2"; Depth:…
Brand: Amana Mfg #: ASZ140241

Gas/Electric Packaged Air Conditioner 14 SEER, Single-Phase, 2 Ton, 81% AFUE, R410A, Ultra LowNOx B64-920
Gas/Electric Packaged Air Conditioner 14 SEER, Single-Phase, 2 Ton, 81% AFUE, R410A, Ultra LowNOx
SEER: 14; EER: 11; Nom. Tons: 2; BtuH Cooling: 23,000; BtuH Heating Input: 40,000; BtuH Heating Output: 31,000; Volts: 208/230; Phase: Single; Nom. CFM: 800; Min. Circuit Amps: 14.4; Refrigerant: R410A; Width: 47"; Height: 32"; Depth: 51"; Wt. Lbs.: 412;
Brand: Goodman Mfg #: GPU1424040M41

Air Conditioning Condensing Unit 13 SEER, Single-Phase, 2 Ton, R410A B99-212
Air Conditioning Condensing Unit 13 SEER, Single-Phase, 2 Ton, R410A
SEER: 13; EER: 11.0; Nom. Tons: 2; BtuH Cooling: 23,000; Volts: 208-230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 17.6; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 26"; Height: 27-1/2"; Depth: 26"; Wt. Lbs.: 145; OEM TXV: B18-099;
Brand: Amana Mfg #: ASX130241

Heat Pump LX Series, 16 SEER, Single-Phase, Modulating, 2 Ton, R410A B78-406
Heat Pump LX Series, 16 SEER, Single-Phase, Modulating, 2 Ton, R410A
SEER: 16; EER: 11.75; Nom. Tons: 2; BtuH Cooling: 24,000; BtuH Heating Input: 24,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.0; COP: 3.8; Min. Circuit Amps: 17.2; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29-1/4"; Height: 33-1/4";…
Brand: Coleman Mfg #: CH16B2421S

Air Conditioning Condensing Unit 14 SEER, Single-Phase, 2 Ton, R410A B76-746
Air Conditioning Condensing Unit 14 SEER, Single-Phase, 2 Ton, R410A
SEER: 14; EER: 11.5; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 17.6; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 26"; Height: 32-1/2"; Depth: 26"; Wt. Lbs.: 153; OEM TXV: B18-099;
Brand: Amana Mfg #: ASX140241

Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 2 Ton, R410A, Fin Tube, Southeast Region Only B77-440
Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 2 Ton, R410A, Fin Tube, Southeast Region Only
SEER: 14; EER: 11.7; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 13.6; Max. Fuse Size: 20; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29-1/4"; Height: 30"; Depth: 29-1/4"; Wt. Lbs.: 131; OEM TXV: B19-657; OEM TXV…
Brand: Coleman Mfg #: TF4B2421S
FTL Finance
Powered by Site Search powered by SLI Systems
Select products to compare.
Compare