60 Results

4, 3, 12-1/2, 13 to 13.2, 10 to 10.9, HVAC Equipment

Heat Pump 15 SEER, Single-Phase, 3 Ton, R410A B65-705
Heat Pump 15 SEER, Single-Phase, 3 Ton, R410A
SEER: 15; EER: 10.4; Nom. Tons: 3; BtuH Cooling: 34,200; BtuH Heating Input: 35,000; Volts: 208/230; Phase: Single; HSPF: 9.0; Min. Circuit Amps: 26.7; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 28"; Height: 24-15/16"; Depth: 28"; Wt. Lbs.: 134;
Brand: Bosch Mfg #: BOVA36HDN1M15G

Heat Pump 20 SEER, Single-Phase, 3 Ton, R410A, Connected B66-242
Heat Pump 20 SEER, Single-Phase, 3 Ton, R410A, Connected
SEER: 20; EER: 13.0; Nom. Tons: 3; BtuH Cooling: 34,600; BtuH Heating Input: 34,200; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 10.5; Min. Circuit Amps: 26.3; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29-1/8"; Height: 24.938"; Depth: 29…
Brand: Bosch Mfg #: BOVB-36HDN1-M20G

Heat Pump 16 SEER, Single-Phase, 3 Ton, R410A B61-218
Heat Pump 16 SEER, Single-Phase, 3 Ton, R410A
SEER: 16; EER: 13; Nom. Tons: 3; BtuH Cooling: 36,000; BtuH Heating Input: 36,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.0; COP: 3.36; Min. Circuit Amps: 22.0; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 35-1/4"; Height: 39-1/2";…
Brand: Coleman Mfg #: CH6B3621S

Heat Pump 16 SEER, Single-Phase, 4 Ton, R410A B61-220
Heat Pump 16 SEER, Single-Phase, 4 Ton, R410A
SEER: 16; EER: 13; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 48,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.0; COP: 4.04; Min. Circuit Amps: 25.9; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 38"; Height: 46"; Depth:…
Brand: Coleman Mfg #: CH6B4821S

Air Conditioning Condensing Unit Echelon™ 19 SEER, Single-Phase, 4 Ton, R410A B60-667
Air Conditioning Condensing Unit Echelon™ 19 SEER, Single-Phase, 4 Ton, R410A
SEER: 19; EER: 13.5; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 28.2; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 38-1/4"; Height: 46-1/2"; Depth: 34-1/2"; Wt. Lbs.: 295; OEM TXV: B19-659; OEM…
Brand: Coleman Mfg #: AC19B4821S

Heat Pump 16 SEER, Two-Stage, Single-Phase, 3 Tons, R410A B61-612
Heat Pump 16 SEER, Two-Stage, Single-Phase, 3 Tons, R410A
SEER: 16; EER: 13.0; Nom. Tons: 3; BtuH Cooling: 36,000; BtuH Heating Input: 36,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.0; COP: 4.4; Min. Circuit Amps: 19.5; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 40"; Depth:…
Brand: Goodman Mfg #: GSZC160361

Heat Pump 18 SEER, Two-Stage, Single-Phase, 4 Tons, R410A B61-609
Heat Pump 18 SEER, Two-Stage, Single-Phase, 4 Tons, R410A
SEER: 18; EER: 13.0; Nom. Tons: 4; BtuH Cooling: 49,500; BtuH Heating Input: 51,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.5; COP: 4.76; Min. Circuit Amps: 28.3; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 35-1/2"; Height: 40";…
Brand: Goodman Mfg #: GSZC180481

Air Conditioning Condensing Unit 20 SEER, Single-Phase, Modulating, 4 Ton, R410A B79-687
Air Conditioning Condensing Unit 20 SEER, Single-Phase, Modulating, 4 Ton, R410A
SEER: 20; EER: 13; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 28.6; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 34-1/2"; Height: 43-1/4"; Depth: 38-1/4"; Wt. Lbs.: 264;
Brand: Coleman Mfg #: AC21B4821S

Heat Pump 16 SEER, Two-Stage, Single-Phase, 4 Tons, R410A B61-613
Heat Pump 16 SEER, Two-Stage, Single-Phase, 4 Tons, R410A
SEER: 16; EER: 13.0; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 48,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.0; COP: 5.16; Min. Circuit Amps: 26.5; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 35-1/2"; Height: 34-5/8";…
Brand: Goodman Mfg #: GSZC160481

Horizontal Discharge Heat Pump 17 SEER, Single-Phase, Modulating, 3 Ton, R410A B64-414
Horizontal Discharge Heat Pump 17 SEER, Single-Phase, Modulating, 3 Ton, R410A
SEER: 18; EER: 10; Nom. Tons: 3; BtuH Cooling: 36,000; BtuH Heating Input: 36,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 10.5; COP: 3.4; Min. Circuit Amps: 23; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 37-3/8"; Height: 33"; Depth:…
Brand: Coleman Mfg #: HMH72B361S

Horizontal Discharge Heat Pump 17 SEER, Single-Phase, Modulating, 4 Ton, R410A B64-415
Horizontal Discharge Heat Pump 17 SEER, Single-Phase, Modulating, 4 Ton, R410A
SEER: 18; EER: 10.5; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 46,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.5; COP: 3.34; Min. Circuit Amps: 36; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 37-3/8"; Height: 54-5/8";…
Brand: Coleman Mfg #: HMH72B481S

Heat Pump 16 SEER, Single-Phase, 3 Ton, R410A B77-554
Heat Pump 16 SEER, Single-Phase, 3 Ton, R410A
SEER: 16; EER: 13.0; Nom. Tons: 3; BtuH Cooling: 36,000; BtuH Heating Input: 36,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 9.0; COP: 4.99; Min. Circuit Amps: 18.9; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 40"; Depth:…
Brand: Goodman Mfg #: GSZ160361

Air Conditioning Condensing Unit 16 SEER, Two-Stage, Single-Phase, 3 Tons, R410A B61-604
Air Conditioning Condensing Unit 16 SEER, Two-Stage, Single-Phase, 3 Tons, R410A
SEER: 16; EER: 13.0; Nom. Tons: 3; BtuH Cooling: 36,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 19.7; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-3/4"; Height: 36-1/2"; Depth: 35-3/4"; Wt. Lbs.: 201; OEM TXV: B14-850;
Brand: Goodman Mfg #: GSXC160361

Heat Pump 16 SEER, Single-Phase, 4 Ton, R410A B77-556
Heat Pump 16 SEER, Single-Phase, 4 Ton, R410A
SEER: 16; EER: 13.0; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 48,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 9.0; COP: 4.75; Min. Circuit Amps: 26.2; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 35-1/2"; Height: 34-5/8";…
Brand: Goodman Mfg #: GSZ160481

Air Conditioning Condensing Unit 18 SEER, Two-Stage, Single-Phase, 3 Tons, R410A B61-600
Air Conditioning Condensing Unit 18 SEER, Two-Stage, Single-Phase, 3 Tons, R410A
SEER: 18; EER: 13.5; Nom. Tons: 3; BtuH Cooling: 36,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 21.3; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-3/4"; Height: 40"; Depth: 35-3/4"; Wt. Lbs.: 238; OEM TXV: B14-850;
Brand: Goodman Mfg #: GSXC180361

Air Conditioning Condensing Unit 18 SEER, Two-Stage, Single-Phase, 4 Tons, R410A B61-601
Air Conditioning Condensing Unit 18 SEER, Two-Stage, Single-Phase, 4 Tons, R410A
SEER: 18; EER: 13.5; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 28.3; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 35-3/4"; Height: 42-1/4"; Depth: 35-3/4"; Wt. Lbs.: 298; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSXC180481

Air Conditioning Condensing Unit 16 SEER, Two-Stage, Single-Phase, 4 Tons, R410A B61-605
Air Conditioning Condensing Unit 16 SEER, Two-Stage, Single-Phase, 4 Tons, R410A
SEER: 16; EER: 13.0; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 26.7; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 35-3/4"; Height: 37"; Depth: 35-3/4"; Wt. Lbs.: 263; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSXC160481

Air Conditioning Condensing Unit 16 SEER, Single-Phase, 3 Ton, R410A B60-822
Air Conditioning Condensing Unit 16 SEER, Single-Phase, 3 Ton, R410A
SEER: 16; EER: 13.0; Nom. Tons: 3; BtuH Cooling: 34,800; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 18.6; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 29"; Height: 39-1/2"; Depth: 29"; Wt. Lbs.: 162; OEM TXV: B18-725;
Brand: Goodman Mfg #: GSX16S361

Single Packaged Gas/Electric Air Conditioner Point Core Series, Three-Phase, 12-1/2T, R410A B60-720
Single Packaged Gas/Electric Air Conditioner Point Core Series, Three-Phase, 12-1/2T, R410A
EER: 10.8; Nom. Tons: 12-1/2; BtuH Cooling: 135,000; BtuH Heating Input: 220,000; BtuH Heating Output: 176,000; Volts: 208/230; Phase: 3; Nom. CFM: 4,000; Refrigerant: R410A; Width: 61-7/10"; Height: 55-13/50"; Depth: 87-1/5"; Wt. Lbs.: 1,047;
Brand: Coleman Mfg #: ZXG14E2C3AA1A111A3

Single Packaged Gas/Electric Air Conditioner Point Core Series, Three-Phase, 12-1/2T, R410A B60-718
Single Packaged Gas/Electric Air Conditioner Point Core Series, Three-Phase, 12-1/2T, R410A
EER: 10.8; Nom. Tons: 12-1/2; BtuH Cooling: 135,000; BtuH Heating Input: 180,000; BtuH Heating Output: 144,000; Volts: 208/230; Phase: 3; Nom. CFM: 4,000; Refrigerant: R410A; Width: 61-7/10"; Height: 55-13/50"; Depth: 87-1/5"; Wt. Lbs.: 1,047;
Brand: Coleman Mfg #: ZXG14D2C3AA1A111A3

Single Packaged Heat Pump 12.5 IEER/10.6 EER,Three-Phase, 12-1/2 Ton, R410A B65-351
Single Packaged Heat Pump 12.5 IEER/10.6 EER,Three-Phase, 12-1/2 Ton, R410A
Nom. Tons: 12-1/2; BtuH Cooling: 140,000; BtuH Heating Input: 140,000; EER: 10.6; HSPF: 8.0; COP: 3.2; Motor Type: 2-Speed Belt; Volts: 208/230V; Nom. CFM: 4,250; Min. Circuit Amps: 65.0; Width: 93-3/4"; Height: 58-3/5"; Depth: 60-3/8"; Wt. Lbs.: 1,314;
Brand: Daikin Mfg #: DBH1503V000001S

Single Packaged Gas/Electric Air Conditioner Point Core Series, Three-Phase, 12-1/2T, R410A B60-721
Single Packaged Gas/Electric Air Conditioner Point Core Series, Three-Phase, 12-1/2T, R410A
EER: 10.8; Nom. Tons: 12-1/2; BtuH Cooling: 135,000; BtuH Heating Input: 250,000; BtuH Heating Output: 200,000; Volts: 208/230; Phase: 3; Nom. CFM: 4,000; Refrigerant: R410A; Width: 61-7/10"; Height: 55-13/50"; Depth: 87-1/5"; Wt. Lbs.: 1,047;
Brand: Coleman Mfg #: ZXG14F2B3AA1A111A3

Air Conditioning Condensing Unit 16 SEER, Single-Phase, 4 Ton, R410A B60-824
Air Conditioning Condensing Unit 16 SEER, Single-Phase, 4 Ton, R410A
SEER: 16; EER: 13.0; Nom. Tons: 4; BtuH Cooling: 45,500; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 23.7; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 39-1/2"; Depth: 35-1/2"; Wt. Lbs.: 219; OEM TXV: B18-726;
Brand: Goodman Mfg #: GSX16S481

Single Packaged Heat Pump 16 SEER, Single-Phase, 3 Ton, R410A, Horizontal B76-933
Single Packaged Heat Pump 16 SEER, Single-Phase, 3 Ton, R410A, Horizontal
SEER: 16; EER: 13; Nom. Tons: 3; BtuH Cooling: 36,000; BtuH Heating Input: 32,200; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 3.8; Nom. CFM: 1,200; Min. Circuit Amps: 27.0; Refrigerant: R410A; Width: 66"; Height: 35"; Depth: 34"; Wt. Lbs.: 375;
Brand: Goodman Mfg #: GPH1636H41
FTL Finance
Powered by Site Search powered by SLI Systems
Select products to compare.