238 Results

3, 2, 12 to 12.8, 11 to 11.9, HVAC Equipment

Air Conditioning Condensing Unit Horizontal Discharge, 14 SEER, Single-Phase, 2 Ton, R410A B60-174
Air Conditioning Condensing Unit Horizontal Discharge, 14 SEER, Single-Phase, 2 Ton, R410A
SEER: 14; EER: 12.2; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 18.3; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 45"; Height: 37-1/4"; Depth: 20"; Wt. Lbs.: 195; OEM TXV: B19-657; OEM TXV for…
Brand: Coleman Mfg #: TCHE24S41S1

Air Conditioning Condensing Unit Horizontal Discharge, 14 SEER, Single-Phase, 3 Ton, R410A B60-175
Air Conditioning Condensing Unit Horizontal Discharge, 14 SEER, Single-Phase, 3 Ton, R410A
SEER: 14; EER: 12.2; Nom. Tons: 3; BtuH Cooling: 36,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 19.1; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 45"; Height: 37-1/4"; Depth: 20"; Wt. Lbs.: 215; OEM TXV: B20-259; OEM TXV for…
Brand: Coleman Mfg #: TCHE36S41S1

Horizontal Discharge Air Conditioning Condenisng Unit 14 SEER, Three-Phase, 3 Ton, R410A, 460V B60-179
Horizontal Discharge Air Conditioning Condenisng Unit 14 SEER, Three-Phase, 3 Ton, R410A, 460V
SEER: 14; EER: 12.20; Nom. Tons: 3; BtuH Cooling: 36,000; Volts: 460; Phase: 3; Min. Circuit Amps: 8.0; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 45"; Height: 37-1/4"; Depth: 20"; Wt. Lbs.: 215;
Brand: Coleman Mfg #: TCHE36S44S1

Single Packaged Gas/Heat Air Conditioner 16 SEER, Three-Phase, 3 Ton, R410A, 81% AFUE B60-723
Single Packaged Gas/Heat Air Conditioner 16 SEER, Three-Phase, 3 Ton, R410A, 81% AFUE
SEER: 16.0; EER: 12.5; Nom. Tons: 3; BtuH Cooling: 36,000; BtuH Heating Input: 65,000; BtuH Heating Output: 52,000; Volts: 208/230; Phase: Three; Motor Type: ECM; Nom. CFM: 1,200; Min. Circuit Amps: 9.9; Refrigerant: R410A; Width: 45-3/4"; Height: 49"; Depth: 51-1/4"; Wt. Lbs.: 461;
Brand: Coleman Mfg #: PCG6B360653X1

Single Packaged Gas/Heat Air Conditioner 16 SEER, Three-Phase, 3 Ton, R410A, 81% AFUE B60-724
Single Packaged Gas/Heat Air Conditioner 16 SEER, Three-Phase, 3 Ton, R410A, 81% AFUE
SEER: 16.0; EER: 12.5; Nom. Tons: 3; BtuH Cooling: 36,000; BtuH Heating Input: 100,000; BtuH Heating Output: 81,000; Volts: 208/230; Phase: Three; Motor Type: ECM; Nom. CFM: 1,200; Min. Circuit Amps: 9.9; Refrigerant: R410A; Width: 45-3/4"; Height: 49"; Depth: 51-1/4"; Wt. Lbs.: 468;
Brand: Coleman Mfg #: PCG6B361003X1

Dual Fuel Packaged Heat Pump 16 SEER, Single-Phase, Single-Stage, 2 Ton, R410A B60-877
Dual Fuel Packaged Heat Pump 16 SEER, Single-Phase, Single-Stage, 2 Ton, R410A
SEER: 16; EER: 12.5; Nom. Tons: 2; BtuH Cooling: 23,400; BtuH Heating Input: 50,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.2; COP: 3.7; Nom. CFM: 800; Min. Circuit Amps: 17.9; Refrigerant: R410A; Width: 35-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 394;
Brand: Coleman Mfg #: PHG6A240502X1

Dual Fuel Packaged Heat Pump 16 SEER, Single-Phase, Single-Stage, 3 Ton, R410A B60-880
Dual Fuel Packaged Heat Pump 16 SEER, Single-Phase, Single-Stage, 3 Ton, R410A
SEER: 16; EER: 12.5; Nom. Tons: 3; BtuH Cooling: 36,400; BtuH Heating Input: 65,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.2; COP: 3.6; Nom. CFM: 1,200; Min. Circuit Amps: 24.6; Refrigerant: R410A; Width: 45-3/4"; Height: 49"; Depth: 51-1/4"; Wt. Lbs.: 498;
Brand: Coleman Mfg #: PHG6B360652X1

Packaged Heat Pump 16 SEER, Single-Phase, Single-Stage, 3 Ton, R410A B60-881
Packaged Heat Pump 16 SEER, Single-Phase, Single-Stage, 3 Ton, R410A
SEER: 16; EER: 12.5; Nom. Tons: 3; BtuH Cooling: 36,400; BtuH Heating Input: 100,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.2; COP: 3.6; Nom. CFM: 1,200; Min. Circuit Amps: 26.2; Refrigerant: R410A; Width: 45-3/4"; Height: 49"; Depth: 51-1/4"; Wt. Lbs.: 505;
Brand: Coleman Mfg #: PHG6B361002X1

Heat Pump LX Series, 14 SEER, Single-Phase, 3 Ton, R410A B61-149
Heat Pump LX Series, 14 SEER, Single-Phase, 3 Ton, R410A
SEER: 14; EER: 12.75; Nom. Tons: 3; BtuH Cooling: 34,000; BtuH Heating Input: 36,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.2; COP: 3.72; Min. Circuit Amps: 21.99; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 38"; Height: 39-1/2";…
Brand: Coleman Mfg #: TH4B3622S

Heat Pump LX Series, 14 SEER, Single-Phase, 3 Ton, R410A B61-150
Heat Pump LX Series, 14 SEER, Single-Phase, 3 Ton, R410A
SEER: 14; EER: 12.0; Nom. Tons: 3; BtuH Cooling: 36,000; BtuH Heating Input: 36,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.0; COP: 3.76; Min. Circuit Amps: 22.0; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 38"; Height: 39-1/2"; Depth:…
Brand: Evcon Mfg #: RHP14L36B23S

Single Packaged Air Conditioner 14 SEER, Single-Phase, 3 Ton, R410A B61-231
Single Packaged Air Conditioner 14 SEER, Single-Phase, 3 Ton, R410A
SEER: 14; EER: 11.2; Nom. Tons: 3; BtuH Cooling: 34,600; Volts: 208/230; Phase: Single; Motor Type: ECM; Nom. CFM: 1,200; Min. Circuit Amps: 26.0; Max. Fuse Size: 40; Refrigerant: R410A; Width: 35-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 382;
Brand: Coleman Mfg #: PCE4A3623

Single Packaged Air Conditioner 14 SEER, Three-Phase, 3 Ton, R410A B61-232
Single Packaged Air Conditioner 14 SEER, Three-Phase, 3 Ton, R410A
SEER: 14; EER: 11.0; Nom. Tons: 3; BtuH Cooling: 34,600; Volts: 208/230; Phase: Three; Motor Type: ECM; Nom. CFM: 1,200; Min. Circuit Amps: 18.1; Max. Fuse Size: 25; Refrigerant: R410A; Width: 35-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 382;
Brand: Coleman Mfg #: PCE4A3632

Single Packaged Air Conditioner 14 SEER, Three-Phase, 3 Ton, R410A B61-233
Single Packaged Air Conditioner 14 SEER, Three-Phase, 3 Ton, R410A
SEER: 14; EER: 11.0; Nom. Tons: 3; BtuH Cooling: 34,600; Volts: 460; Phase: Three; Motor Type: ECM; Nom. CFM: 1,200; Min. Circuit Amps: 9.9; Max. Fuse Size: 15; Refrigerant: R410A; Width: 35-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 382;
Brand: Coleman Mfg #: PCE4A3642

Single Packaged Gas/Heat Air Conditioner 14 SEER, Three-Phase, 3 Ton, R410A, 81% AFUE B61-241
Single Packaged Gas/Heat Air Conditioner 14 SEER, Three-Phase, 3 Ton, R410A, 81% AFUE
SEER: 14; EER: 11; Nom. Tons: 3; BtuH Cooling: 34,600; BtuH Heating Input: 75,000; BtuH Heating Output: 60,000; Volts: 208/230; Phase: Three; Nom. CFM: 1,200; Min. Circuit Amps: 15.5; Refrigerant: R410A; Width: 35-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 427;
Brand: Coleman Mfg #: PCG4A360753X3

Single Packaged Gas/Heat Air Conditioner 14 SEER, Three-Phase, 3 Ton, R410A, 81% AFUE B61-242
Single Packaged Gas/Heat Air Conditioner 14 SEER, Three-Phase, 3 Ton, R410A, 81% AFUE
SEER: 14; EER: 11; Nom. Tons: 3; BtuH Cooling: 34,600; BtuH Heating Input: 100,000; BtuH Heating Output: 80,000; Volts: 208/230; Phase: Three; Nom. CFM: 1,200; Min. Circuit Amps: 17.1; Refrigerant: R410A; Width: 36; Height: 47; Depth: 51-1/4"; Wt. Lbs.: 436;
Brand: Coleman Mfg #: PCG4A361003X1

Single Packaged Gas/Heat Air Conditioner 14 SEER, Three-Phase, 3 Ton, R410A, 81% AFUE B61-243
Single Packaged Gas/Heat Air Conditioner 14 SEER, Three-Phase, 3 Ton, R410A, 81% AFUE
SEER: 14; EER: 11; Nom. Tons: 3; BtuH Cooling: 34,600; BtuH Heating Input: 50,000; BtuH Heating Output: 40,000; Volts: 460; Phase: Three; Nom. CFM: 1,200; Min. Circuit Amps: 7.8; Refrigerant: R410A; Width: 35-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 420;
Brand: Coleman Mfg #: PCG4A360504X2

Single Packaged Gas/Heat Air Conditioner 14 SEER, Three-Phase, 3 Ton, R410A, 81% AFUE B61-244
Single Packaged Gas/Heat Air Conditioner 14 SEER, Three-Phase, 3 Ton, R410A, 81% AFUE
SEER: 14; EER: 11; Nom. Tons: 3; BtuH Cooling: 34,600; BtuH Heating Input: 75,000; BtuH Heating Output: 60,000; Volts: 460; Phase: Three; Nom. CFM: 1,200; Min. Circuit Amps: 7.8; Refrigerant: R410A; Width: 35-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 427;
Brand: Coleman Mfg #: PCG4A360754X2

Single Packaged Gas/Heat Air Conditioner 14 SEER, Three-Phase, 3 Ton, R410A, 81% AFUE B61-245
Single Packaged Gas/Heat Air Conditioner 14 SEER, Three-Phase, 3 Ton, R410A, 81% AFUE
SEER: 14; EER: 11; Nom. Tons: 3; BtuH Cooling: 34,600; BtuH Heating Input: 100,000; BtuH Heating Output: 80,000; Volts: 460; Phase: Three; Nom. CFM: 1,200; Min. Circuit Amps: 9.0; Refrigerant: R410A; Width: 35-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 431;
Brand: Coleman Mfg #: PCG4A361004X2

Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 2 Ton, R410A, Southeast & Northern Region Only B61-252
Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 2 Ton, R410A, Southeast & Northern Region Only
SEER: 14; EER: 11.7; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 14.8; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29-1/4"; Height: 26-3/4"; Depth: 29-1/4"; Wt. Lbs.: 135; OEM TXV: B20-469; OEM…
Brand: Coleman Mfg #: TC4B2422S

Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 3 Ton, R410A, Southeast & Northern Region Only B61-254
Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 3 Ton, R410A, Southeast & Northern Region Only
SEER: 14; EER: 11.7; Nom. Tons: 3; BtuH Cooling: 36,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 19.6; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29-1/4"; Height: 30"; Depth: 29-1/4"; Wt. Lbs.: 145; OEM TXV: B19-657; OEM TXV…
Brand: Coleman Mfg #: TC4B3622S

Air Conditioning Condensing Unit LX Series, 13 SEER, Three-Phase, 3 Ton, R410A B61-258
Air Conditioning Condensing Unit LX Series, 13 SEER, Three-Phase, 3 Ton, R410A
EER: 12.25; Nom. Tons: 3; Volts: 208/230; Phase: Three; Min. Circuit Amps: 14.34; Max. Fuse Size: 20; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29-1/4"; Height: 36-1/4"; Depth: 29-1/4"; Wt. Lbs.: 160;
Brand: Coleman Mfg #: TCD36B32S

Air Conditioning Condensing Unit LX Series, 13 SEER, Three-Phase, 3 Ton, R410A B61-259
Air Conditioning Condensing Unit LX Series, 13 SEER, Three-Phase, 3 Ton, R410A
EER: 12.25; Nom. Tons: 3; Volts: 460; Phase: Three; Min. Circuit Amps: 7.85; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29-1/4"; Height: 36-1/4"; Depth: 29-1/4"; Wt. Lbs.: 160;
Brand: Coleman Mfg #: TCD36B42S

Heat Pump LX Series, 14 SEER, Three-Phase, 3 Ton, R410A B61-263
Heat Pump LX Series, 14 SEER, Three-Phase, 3 Ton, R410A
SEER: 14; EER: 11.75; Nom. Tons: 3; HSPF: 8.55; COP: 3.48; Min. Circuit Amps: 12.58; Max. Fuse Size: 20; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 35-1/4"; Height: 39-1/2"; Depth: 31-3/4"; Wt. Lbs.: 230;
Brand: Coleman Mfg #: THE36B32S

Heat Pump LX Series, 14 SEER, Three-Phase, 3 Ton, R410A B61-264
Heat Pump LX Series, 14 SEER, Three-Phase, 3 Ton, R410A
SEER: 14; EER: 11.75; Nom. Tons: 3; HSPF: 8.55; COP: 3.48; Min. Circuit Amps: 7.05; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 35-1/4"; Height: 39-1/2"; Depth: 31-3/4"; Wt. Lbs.: 230;
Brand: Coleman Mfg #: THE36B42S
FTL Finance
Powered by Site Search powered by SLI Systems
Select products to compare.
Compare