259 Results

5, 4, 2-1/2, 13 to 13.2, 11 to 11.9, HVAC Equipment

Air Conditioning Condensing Unit LX Series, 13 SEER, Three-Phase, 4 Ton, R410A B79-354
Air Conditioning Condensing Unit LX Series, 13 SEER, Three-Phase, 4 Ton, R410A
SEER: 13; EER: 11.75; Nom. Tons: 4; Volts: 208/230; Phase: Three; Min. Circuit Amps: 18.4; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/4"; Height: 33-1/4"; Depth: 31-3/4"; Wt. Lbs.: 200;
Brand: Coleman Mfg #: TCD48B31S

Air Conditioning Condensing Unit LX Series, 13 SEER, Three-Phase, 5 Ton, R410A B79-356
Air Conditioning Condensing Unit LX Series, 13 SEER, Three-Phase, 5 Ton, R410A
SEER: 13; EER: 11.75; Nom. Tons: 5; Volts: 208/230; Phase: Three; Min. Circuit Amps: 21.2; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 38"; Height: 36-1/4"; Depth: 34-1/4"; Wt. Lbs.: 205;
Brand: Coleman Mfg #: TCD60B31S

Air Conditioning Condensing Unit LX Series, 13 SEER, Three-Phase, 5 Ton, R410A B79-357
Air Conditioning Condensing Unit LX Series, 13 SEER, Three-Phase, 5 Ton, R410A
SEER: 13; EER: 11.75; Nom. Tons: 5; Volts: 460; Phase: Three; Min. Circuit Amps: 10.3; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 34-1/4"; Height: 36-1/4"; Depth: 34-1/4"; Wt. Lbs.: 205;
Brand: Coleman Mfg #: TCD60B41S

Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 5 Ton, R410A, 81% AFUE B64-202
Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 5 Ton, R410A, 81% AFUE
SEER: 14; EER: 11.2; Nom. Tons: 5; BtuH Cooling: 56,500; BtuH Heating Input: 100,000; BtuH Heating Output: 80,000; Volts: 208/230V; Phase: Single; Nom. CFM: 1,810; Min. Circuit Amps: 36.5; Refrigerant: R410A; Width: 35-3/4"; Height: 50"; Depth: 51-1/4"; Wt. Lbs.: 475;
Brand: Coleman Mfg #: PCG4B601002X4

Single Packaged Gas/Heat Air Conditioner 14 SEER, Three-Phase, 5 Ton, R410, 81% AFUE, 208/230V B64-212
Single Packaged Gas/Heat Air Conditioner 14 SEER, Three-Phase, 5 Ton, R410, 81% AFUE, 208/230V
SEER: 14; EER: 11.2; Nom. Tons: 5; BtuH Cooling: 56,500; BtuH Heating Input: 65,000; BtuH Heating Output: 52,000; Volts: 208/230; Phase: Three; Motor Type: ECM; Nom. CFM: 1,810; Min. Circuit Amps: 25.2; Refrigerant: R410A; Width: 45-3/4"; Height: 50"; Depth: 51-1/4"; Wt. Lbs.: 469;
Brand: Coleman Mfg #: PCG4B600653X4

Air Conditioning Condensing Unit 13 SEER, Three-Phase, 5 Ton, R410A B74-111
Air Conditioning Condensing Unit 13 SEER, Three-Phase, 5 Ton, R410A
SEER: 13; EER: 11.5; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Three; Min. Circuit Amps: 21.3; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 35-1/2"; Height: 38-1/4"; Depth: 35-1/2"; Wt. Lbs.: 301;
Brand: Daikin Mfg #: DX13SA0603

Air Conditioning Condensing Unit 13 SEER, Three-Phase, 5 Ton, R410A B74-112
Air Conditioning Condensing Unit 13 SEER, Three-Phase, 5 Ton, R410A
SEER: 13; EER: 11.5; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 460; Phase: Three; Min. Circuit Amps: 10.6; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 35-1/2"; Height: 38-1/4"; Depth: 35-1/2"; Wt. Lbs.: 301;
Brand: Daikin Mfg #: DX13SA0604

Air Conditioning Condensing Unit 13 SEER, Three-Phase, 4 Ton, R410A B74-085
Air Conditioning Condensing Unit 13 SEER, Three-Phase, 4 Ton, R410A
SEER: 13; EER: 11.3; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Three; Min. Circuit Amps: 17.6; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 29"; Height: 36-1/4"; Depth: 29"; Wt. Lbs.: 190;
Brand: Daikin Mfg #: DX13SA0483

Heat Pump 16 SEER, Single-Phase, 2-1/2 Ton, R410A B61-217
Heat Pump 16 SEER, Single-Phase, 2-1/2 Ton, R410A
SEER: 16; EER: 13; Nom. Tons: 2-1/2; BtuH Cooling: 30,000; BtuH Heating Input: 30,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.0; COP: 3.22; Min. Circuit Amps: 19.6; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 35-1/4"; Height: 39-1/2";…
Brand: Coleman Mfg #: CH6B3021S

Heat Pump 16 SEER, Single-Phase, 4 Ton, R410A B61-220
Heat Pump 16 SEER, Single-Phase, 4 Ton, R410A
SEER: 16; EER: 13; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 48,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.0; COP: 4.04; Min. Circuit Amps: 25.9; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 38"; Height: 46"; Depth:…
Brand: Coleman Mfg #: CH6B4821S

Air Conditioning Condensing Unit Echelon™ 19 SEER, Single-Phase, 4 Ton, R410A B60-667
Air Conditioning Condensing Unit Echelon™ 19 SEER, Single-Phase, 4 Ton, R410A
SEER: 19; EER: 13.5; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 28.2; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 38-1/4"; Height: 46-1/2"; Depth: 34-1/2"; Wt. Lbs.: 295; OEM TXV: B19-659; OEM…
Brand: Coleman Mfg #: AC19B4821S

Single Packaged Heat Pump 14 SEER, 2-1/2 Ton, Single-Phase, R410A B64-159
Single Packaged Heat Pump 14 SEER, 2-1/2 Ton, Single-Phase, R410A
SEER: 14; EER: 11.6; Nom. Tons: 2-1/2; BtuH Cooling: 29,600; BtuH Heating Input: 28,200; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 3.7; Nom. CFM: 950; Min. Circuit Amps: 20.5; Refrigerant: R410A; Width: 35-3/4"; Height: 45"; Depth: 51-1/4"; Wt. Lbs.: 355;
Brand: Coleman Mfg #: PHE4A3024

Single Packaged Heat Pump 14 SEER, 5 Ton, Single-Phase, R410A B64-163
Single Packaged Heat Pump 14 SEER, 5 Ton, Single-Phase, R410A
SEER: 14; EER: 11.6; Nom. Tons: 5; BtuH Cooling: 59,500; BtuH Heating Input: 56,500; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 3.6; Nom. CFM: 1,850; Min. Circuit Amps: 36.5; Refrigerant: R410A; Width: 45-3/4"; Height: 55"; Depth: 51-1/4"; Wt. Lbs.: 485;
Brand: Coleman Mfg #: PHE4B6024

Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 5 Ton, R410A, 81% AFUE B64-203
Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 5 Ton, R410A, 81% AFUE
SEER: 14; EER: 11.2; Nom. Tons: 5; BtuH Cooling: 56,500; BtuH Heating Input: 125,000; BtuH Heating Output: 100,000; Volts: 208/230V; Phase: Single; Nom. CFM: 1,810; Min. Circuit Amps: 36.5; Refrigerant: R410A; Width: 35-3/4"; Height: 50"; Depth: 51-1/4"; Wt. Lbs.: 479;
Brand: Coleman Mfg #: PCG4B601252X4

Single Packaged Heat Pump 14 SEER, 4 Ton, Single-Phase, R410A B64-162
Single Packaged Heat Pump 14 SEER, 4 Ton, Single-Phase, R410A
SEER: 14; EER: 11.6; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 46,500; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 3.7; Nom. CFM: 1,500; Min. Circuit Amps: 30.0; Refrigerant: R410A; Width: 45-3/4"; Height: 53"; Depth: 51-1/4"; Wt. Lbs.: 479;
Brand: Coleman Mfg #: PHE4B4824

Air Conditioning Condensing Unit Echelon™ 19 SEER, Single-Phase, 5 Ton, R410A B60-668
Air Conditioning Condensing Unit Echelon™ 19 SEER, Single-Phase, 5 Ton, R410A
SEER: 19; EER: 13.0; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 31.4; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 38-1/4"; Height: 46-1/2"; Depth: 34-1/2"; Wt. Lbs.: 295; OEM TXV: B19-659;…
Brand: Coleman Mfg #: AC19B6021S

Heat Pump 16 SEER, Single-Phase, 5 Ton, R410A B61-221
Heat Pump 16 SEER, Single-Phase, 5 Ton, R410A
SEER: 16; EER: 13; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.0; COP: 3.36; Min. Circuit Amps: 32.4; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 38"; Height: 46"; Depth:…
Brand: Coleman Mfg #: CH6B6021S

Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 4 Ton, R410A, 81% AFUE B64-199
Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 4 Ton, R410A, 81% AFUE
SEER: 14; EER: 11.2; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 100,000; BtuH Heating Output: 80,000; Volts: 208/230V; Phase: Single; Nom. CFM: 1,560; Min. Circuit Amps: 30.0; Refrigerant: R410A; Width: 35-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 456;
Brand: Coleman Mfg #: PCG4B481002X4

Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 4 Ton, R410A, 81% AFUE B64-200
Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 4 Ton, R410A, 81% AFUE
SEER: 14; EER: 11.2; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 125,000; BtuH Heating Output: 100,000; Volts: 208/230V; Phase: Single; Nom. CFM: 1,560; Min. Circuit Amps: 30.0; Refrigerant: R410A; Width: 35-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 460;
Brand: Coleman Mfg #: PCG4B481252X4

Heat Pump 18 SEER, Two-Stage, Single-Phase, 4 Tons, R410A B61-609
Heat Pump 18 SEER, Two-Stage, Single-Phase, 4 Tons, R410A
SEER: 18; EER: 13.0; Nom. Tons: 4; BtuH Cooling: 49,500; BtuH Heating Input: 51,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.5; COP: 4.76; Min. Circuit Amps: 28.3; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 35-1/2"; Height: 40";…
Brand: Goodman Mfg #: GSZC180481

Air Conditioning Condensing Unit 20 SEER, Single-Phase, Modulating, 4 Ton, R410A B79-687
Air Conditioning Condensing Unit 20 SEER, Single-Phase, Modulating, 4 Ton, R410A
SEER: 20; EER: 13; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 28.6; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 34-1/2"; Height: 43-1/4"; Depth: 38-1/4"; Wt. Lbs.: 264;
Brand: Coleman Mfg #: AC21B4821S

Heat Pump 16 SEER, Two-Stage, Single-Phase, 4 Tons, R410A B61-613
Heat Pump 16 SEER, Two-Stage, Single-Phase, 4 Tons, R410A
SEER: 16; EER: 13.0; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 48,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.0; COP: 5.16; Min. Circuit Amps: 26.5; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 35-1/2"; Height: 34-5/8";…
Brand: Goodman Mfg #: GSZC160481

Air Conditioning Condensing Unit 13 SEER, Three-Phase, 4 Ton, R410A B74-086
Air Conditioning Condensing Unit 13 SEER, Three-Phase, 4 Ton, R410A
SEER: 13; EER: 11.3; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 460; Phase: Three; Min. Circuit Amps: 8.4; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 29"; Height: 36-1/4"; Depth: 29"; Wt. Lbs.: 189;
Brand: Daikin Mfg #: DX13SA0484

Single Packaged Air Conditioner 14 SEER, Single-Phase, 5 Ton, R410A B64-147
Single Packaged Air Conditioner 14 SEER, Single-Phase, 5 Ton, R410A
SEER: 14; EER: 11.2; Nom. Tons: 5; BtuH Cooling: 56,500; Volts: 208/230; Phase: Single; Motor Type: ECM; Nom. CFM: 1,810; Min. Circuit Amps: 36.5; Max. Fuse Size: 50; Refrigerant: R410A; Width: 45-3/4"; Height: 50"; Depth: 51-1/4"; Wt. Lbs.: 450;
Brand: Coleman Mfg #: PCE4B6024