146 Results

14, 4, 3, 13 to 13.2, 11 to 11.9, HVAC Equipment

Single Packaged Gas/Heat Air Conditioner 14 SEER, Three-Phase, 3 Ton, R410A, 81% AFUE, 208/230V B64-206
Single Packaged Gas/Heat Air Conditioner 14 SEER, Three-Phase, 3 Ton, R410A, 81% AFUE, 208/230V
SEER: 14; EER: 11.8; Nom. Tons: 3; BtuH Cooling: 35,800; BtuH Heating Input: 100,000; BtuH Heating Output: 80,000; Volts: 208/230; Phase: Three; Motor Type: ECM; Nom. CFM: 1,165; Min. Circuit Amps: 17.7; Refrigerant: R410A; Width: 35-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 383;
Brand: Coleman Mfg #: PCG4A361003X4

Single Packaged Heat Pump 14 SEER, 3 Ton, Single-Phase, R410A B64-160
Single Packaged Heat Pump 14 SEER, 3 Ton, Single-Phase, R410A
SEER: 14; EER: 11.6; Nom. Tons: 3; BtuH Cooling: 35,800; BtuH Heating Input: 34,800; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 3.6; Nom. CFM: 1,150; Min. Circuit Amps: 23.9; Refrigerant: R410A; Width: 45-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 420;
Brand: Coleman Mfg #: PHE4B3624

Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 3 Ton, R410A, 81% AFUE B64-195
Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 3 Ton, R410A, 81% AFUE
SEER: 14; EER: 11.8; Nom. Tons: 3; BtuH Cooling: 35,800; BtuH Heating Input: 100,000; BtuH Heating Output: 80,000; Volts: 208/230V; Phase: Single; Nom. CFM: 1,165; Min. Circuit Amps: 25.5; Refrigerant: R410A; Width: 35-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 383;
Brand: Coleman Mfg #: PCG4A361002X4

Single Packaged Heat Pump 14 SEER, 4 Ton, Single-Phase, R410A B64-162
Single Packaged Heat Pump 14 SEER, 4 Ton, Single-Phase, R410A
SEER: 14; EER: 11.6; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 46,500; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 3.7; Nom. CFM: 1,500; Min. Circuit Amps: 30.0; Refrigerant: R410A; Width: 45-3/4"; Height: 53"; Depth: 51-1/4"; Wt. Lbs.: 479;
Brand: Coleman Mfg #: PHE4B4824

Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 4 Ton, R410A, 81% AFUE B64-199
Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 4 Ton, R410A, 81% AFUE
SEER: 14; EER: 11.2; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 100,000; BtuH Heating Output: 80,000; Volts: 208/230V; Phase: Single; Nom. CFM: 1,560; Min. Circuit Amps: 30.0; Refrigerant: R410A; Width: 35-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 456;
Brand: Coleman Mfg #: PCG4B481002X4

Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 4 Ton, R410A, 81% AFUE B64-200
Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 4 Ton, R410A, 81% AFUE
SEER: 14; EER: 11.2; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 125,000; BtuH Heating Output: 100,000; Volts: 208/230V; Phase: Single; Nom. CFM: 1,560; Min. Circuit Amps: 30.0; Refrigerant: R410A; Width: 35-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 460;
Brand: Coleman Mfg #: PCG4B481252X4

Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 3 Ton, R410A, 81% AFUE B64-194
Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 3 Ton, R410A, 81% AFUE
SEER: 14; EER: 11.8; Nom. Tons: 3; BtuH Cooling: 35,800; BtuH Heating Input: 75,000; BtuH Heating Output: 60,000; Volts: 208/230V; Phase: Single; Nom. CFM: 1,165; Min. Circuit Amps: 23.9; Refrigerant: R410A; Width: 35-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 379;
Brand: Coleman Mfg #: PCG4A360752X4

Single Packaged Air Conditioner 14 SEER, Single-Phase, 3 Ton, R410A B64-144
Single Packaged Air Conditioner 14 SEER, Single-Phase, 3 Ton, R410A
SEER: 14; EER: 11.8; Nom. Tons: 3; BtuH Cooling: 35,800; Volts: 208/230; Phase: Single; Motor Type: ECM; Nom. CFM: 1,165; Min. Circuit Amps: 23.9; Max. Fuse Size: 35; Refrigerant: R410A; Width: 35-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 350;
Brand: Coleman Mfg #: PCE4A3624

Single Packaged Air Conditioner 14 SEER, Single-Phase, 4 Ton, R410A B64-146
Single Packaged Air Conditioner 14 SEER, Single-Phase, 4 Ton, R410A
SEER: 14; EER: 11.2; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Nom. CFM: 1,560; Min. Circuit Amps: 30.0; Max. Fuse Size: 45; Refrigerant: R410A; Width: 45-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 431;
Brand: Coleman Mfg #: PCE4B4824

Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 4 Ton, R410A, 81% AFUE B64-198
Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 4 Ton, R410A, 81% AFUE
SEER: 14; EER: 11.2; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 65,000; BtuH Heating Output: 52,000; Volts: 208/230V; Phase: Single; Nom. CFM: 1,560; Min. Circuit Amps: 30.0; Refrigerant: R410A; Width: 35-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 450;
Brand: Coleman Mfg #: PCG4B480652X4

Single Packaged Gas/Heat Air Conditioner 14 SEER, Three-Phase, 3 Ton, R410A, 81% AFUE, 208/230V B64-204
Single Packaged Gas/Heat Air Conditioner 14 SEER, Three-Phase, 3 Ton, R410A, 81% AFUE, 208/230V
SEER: 14; EER: 11.8; Nom. Tons: 3; BtuH Cooling: 35,800; BtuH Heating Input: 50,000; BtuH Heating Output: 40,000; Volts: 208/230; Phase: Three; Motor Type: ECM; Nom. CFM: 1,165; Min. Circuit Amps: 16.1; Refrigerant: R410A; Width: 35-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 359;
Brand: Coleman Mfg #: PCG4A360503X4

Heat Pump LX Series, 14 SEER, Three-Phase, 3 Ton, R410A B61-263
Heat Pump LX Series, 14 SEER, Three-Phase, 3 Ton, R410A
SEER: 14; EER: 11.75; Nom. Tons: 3; HSPF: 8.55; COP: 3.48; Min. Circuit Amps: 12.58; Max. Fuse Size: 20; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 35-1/4"; Height: 39-1/2"; Depth: 31-3/4"; Wt. Lbs.: 230;
Brand: Coleman Mfg #: THE36B32S

Single Packaged Gas/Heat Air Conditioner 14 SEER, Three-Phase, 4 Ton, R410A, 81% AFUE, 460V B64-220
Single Packaged Gas/Heat Air Conditioner 14 SEER, Three-Phase, 4 Ton, R410A, 81% AFUE, 460V
SEER: 14; EER: 11.2; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 125,000; BtuH Heating Output: 100,000; Volts: 460; Phase: Three; Motor Type: ECM; Nom. CFM: 1,560; Min. Circuit Amps: 11.5; Refrigerant: R410A; Width: 45-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 460;
Brand: Coleman Mfg #: PCG4B481254X4

Single Packaged Gas/Heat Air Conditioner 14 SEER, Three-Phase, 3 Ton, R410A, 81% AFUE, 208/230V B64-205
Single Packaged Gas/Heat Air Conditioner 14 SEER, Three-Phase, 3 Ton, R410A, 81% AFUE, 208/230V
SEER: 14; EER: 11.8; Nom. Tons: 3; BtuH Cooling: 35,800; BtuH Heating Input: 75,000; BtuH Heating Output: 60,000; Volts: 208/230; Phase: Three; Motor Type: ECM; Nom. CFM: 1,165; Min. Circuit Amps: 16.1; Refrigerant: R410A; Width: 35-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 379;
Brand: Coleman Mfg #: PCG4A360753X4

Single Packaged Gas/Electric Air Conditioner 14 SEER, Three-Phase, 3 Ton, 81% AFUE, R410A, Multi-Position B79-255
Single Packaged Gas/Electric Air Conditioner 14 SEER, Three-Phase, 3 Ton, 81% AFUE, R410A, Multi-Position
SEER: 14; EER: 11.0; Nom. Tons: 3; BtuH Cooling: 34,200; BtuH Heating Input: 80,000; BtuH Heating Output: 64,800; Volts: 208/230; Phase: Three; Motor Type: EEM; Nom. CFM: 1,200; Min. Circuit Amps: 16.6; Refrigerant: R410A; Width: 47"; Height: 34-3/4"; Depth: 51"; Wt. Lbs.: 458;
Brand: Daikin Mfg #: DP14GM3608043

Single Packaged Gas/Heat Air Conditioner 14 SEER, Three-Phase, 4 Ton, R410A, 81% AFUE, 208/230V B64-211
Single Packaged Gas/Heat Air Conditioner 14 SEER, Three-Phase, 4 Ton, R410A, 81% AFUE, 208/230V
SEER: 14; EER: 11.2; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 125,000; BtuH Heating Output: 100,000; Volts: 208/230; Phase: Three; Motor Type: ECM; Nom. CFM: 1,560; Min. Circuit Amps: 20.2; Refrigerant: R410A; Width: 45-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 460;
Brand: Coleman Mfg #: PCG4B481253X4

Heat Pump 14 SEER, Single-Phase, 3 Ton, R410A B64-281
Heat Pump 14 SEER, Single-Phase, 3 Ton, R410A
SEER: 14; EER: 11.5; Nom. Tons: 3; BtuH Cooling: 36,000; BtuH Heating Input: 36,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.2; COP: 4.28; Min. Circuit Amps: 19.3; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 29"; Height: 36-1/4"; Depth:…
Brand: Goodman Mfg #: GSZ140361

Single Packaged Gas/Heat Air Conditioner 14 SEER, Three-Phase, 3 Ton, R410A, 81% AFUE, 460V B64-216
Single Packaged Gas/Heat Air Conditioner 14 SEER, Three-Phase, 3 Ton, R410A, 81% AFUE, 460V
SEER: 14; EER: 11.8; Nom. Tons: 3; BtuH Cooling: 35,800; BtuH Heating Input: 75,000; BtuH Heating Output: 60,000; Volts: 460; Phase: Three; Motor Type: ECM; Nom. CFM: 1,165; Min. Circuit Amps: 7.6; Refrigerant: R410A; Width: 35-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 379;
Brand: Coleman Mfg #: PCG4A360754X4

Single Packaged Air Conditioner 14 SEER, Three-Phase, 3 Ton, R410A B64-152
Single Packaged Air Conditioner 14 SEER, Three-Phase, 3 Ton, R410A
SEER: 14; EER: 11.8; Nom. Tons: 3; BtuH Cooling: 35,800; Volts: 208/230; Phase: Three; Motor Type: ECM; Nom. CFM: 1,165; Min. Circuit Amps: 16.1; Max. Fuse Size: 20; Refrigerant: R410A; Width: 35-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 350;
Brand: Coleman Mfg #: PCE4A3634

Single Packaged Air Conditioner 14 SEER, Three-Phase, 4 Ton, R410A, Multi-Position B79-260
Single Packaged Air Conditioner 14 SEER, Three-Phase, 4 Ton, R410A, Multi-Position
SEER: 14; EER: 11.0; Nom. Tons: 4; BtuH Cooling: 46,500; Volts: 208/230; Phase: Three; Motor Type: EEM; Nom. CFM: 1,600; Min. Circuit Amps: 23.2; Max. Fuse Size: 35; Refrigerant: R410A; Width: 47"; Height: 42-3/4"; Depth: 51"; Wt. Lbs.: 435; BtuH Heating Input: 48,000;
Brand: Daikin Mfg #: DP14CM4843

Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 4 Ton, R410A, Southeast & Northern Region Only B77-430
Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 4 Ton, R410A, Southeast & Northern Region Only
SEER: 14; EER: 11.7; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 25.7; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/4"; Height: 33-1/4"; Depth: 31-3/4"; Wt. Lbs.: 200; OEM TXV: B19-659; OEM…
Brand: Coleman Mfg #: TC4B4821S

Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 3 Ton, R410A, 81% AFUE B64-193
Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 3 Ton, R410A, 81% AFUE
SEER: 14; EER: 11.8; Nom. Tons: 3; BtuH Cooling: 35,800; BtuH Heating Input: 50,000; BtuH Heating Output: 40,000; Volts: 208/230V; Phase: Single; Nom. CFM: 1,165; Min. Circuit Amps: 23.9; Refrigerant: R410A; Width: 35-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 359;
Brand: Coleman Mfg #: PCG4A360502X4

Heat Pump 14 SEER, Single-Phase, 4 Ton, R410A B75-918
Heat Pump 14 SEER, Single-Phase, 4 Ton, R410A
SEER: 14; EER: 11.5; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 48,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.5; COP: 4.72; Min. Circuit Amps: 24.6; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 29"; Height: 36-1/4";…
Brand: Goodman Mfg #: GSZ140481

Single Packaged Air Conditioner 14 SEER, Three-Phase, 3 Ton, R410A, Multi-Position B79-259
Single Packaged Air Conditioner 14 SEER, Three-Phase, 3 Ton, R410A, Multi-Position
SEER: 14; EER: 11.0; Nom. Tons: 3; BtuH Cooling: 35,000; Volts: 208/230; Phase: Three; Motor Type: PSC; Nom. CFM: 1,200; Min. Circuit Amps: 18.2; Max. Fuse Size: 25; Refrigerant: R410A; Width: 47"; Height: 34-3/4"; Depth: 51"; Wt. Lbs.: 365; BtuH Heating Input: 36,000;
Brand: Daikin Mfg #: DP14CM3643