160 Results

4, 2, 10, 11 to 11.9, HVAC Equipment

Heat Pump 14 SEER, Single-Phase, 4 Ton, R410A B75-918
Heat Pump 14 SEER, Single-Phase, 4 Ton, R410A
SEER: 14; EER: 11.5; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 48,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.5; COP: 4.72; Min. Circuit Amps: 24.6; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 29"; Height: 36-1/4";…
Brand: Goodman Mfg #: GSZ140481

Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 4 Ton, R410A B77-528
Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 4 Ton, R410A
SEER: 13; EER: 11; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 28.5; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 29-1/4"; Height: 30"; Depth: 29-1/4"; Wt. Lbs.: 175; OEM TXV: B19-659; OEM TXV…
Brand: Evcon Mfg #: RAC13L48B23S

Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 2 Ton, R410A, Southeast & Northern Region Only B61-252
Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 2 Ton, R410A, Southeast & Northern Region Only
SEER: 14; EER: 11.7; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 14.8; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29-1/4"; Height: 26-3/4"; Depth: 29-1/4"; Wt. Lbs.: 135; OEM TXV: B20-469; OEM…
Brand: Coleman Mfg #: TC4B2422S

Air Conditioning Condensing Unit 14 SEER, Single-Phase, 2 Ton, R410A B75-907
Air Conditioning Condensing Unit 14 SEER, Single-Phase, 2 Ton, R410A
SEER: 14; EER: 11.5; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 14.2; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 26"; Height: 27-1/2"; Depth: 26"; Wt. Lbs.: 131; OEM TXV: B18-099;
Brand: Goodman Mfg #: GSX140241

Air Conditioning Condensing Unit Thru-The-Wall 13 SEER, Single-Phase, 2 TON, R410A B61-349
Air Conditioning Condensing Unit Thru-The-Wall 13 SEER, Single-Phase, 2 TON, R410A
Nom. Tons: 2; SEER: 13; EER: 11; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Width: 24-1/8"; Height: 32"; Depth: 18-1/2"; Wt. Lbs.: 180;
Brand: National Comfort Products Mfg #: NCPE-424-3010

Air Conditioning Condensing Unit 14 SEER, Single-Phase, 4 Ton, R410A B75-911
Air Conditioning Condensing Unit 14 SEER, Single-Phase, 4 Ton, R410A
SEER: 14; EER: 11.7; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 26.4; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 35-1/2"; Height: 36-1/4"; Depth: 35-1/2"; Wt. Lbs.: 220; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSX140481

Air Conditioning Condensing Unit 11.2 EER, Three-Phase, 10 Ton, R410A B60-948
Air Conditioning Condensing Unit 11.2 EER, Three-Phase, 10 Ton, R410A
EER: 11.2; Nom. Tons: 10; BtuH Cooling: 120,000; Volts: 208/230; Phase: 3; Min. Circuit Amps: 46.4; Max. Fuse Size: 70; Liquid Conn.: 5/8"; Suction Fitting: 1-3/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 41-1/2"; Depth: 35-1/2"; Wt. Lbs.: 345;
Brand: Daikin Mfg #: DX11TA1203

Single Packaged Heat Pump 14 SEER, Single-Phase, 2 Tons, R410A, Multi-Position B76-801
Single Packaged Heat Pump 14 SEER, Single-Phase, 2 Tons, R410A, Multi-Position
SEER: 14; EER: 11; Nom. Tons: 2; BtuH Cooling: 24,000; BtuH Heating Input: 23,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 3.6; Nom. CFM: 850; Min. Circuit Amps: 21.8; Refrigerant: R410A; Width: 47"; Height: 34-3/4"; Depth: 51"; Wt. Lbs.: 380;
Brand: Goodman Mfg #: GPH1424M41

Single Packaged Gas/Heat Air Conditioner 14 SEER, Three-Phase, 4 Ton, R410A, 81% AFUE, 208/230V B64-210
Single Packaged Gas/Heat Air Conditioner 14 SEER, Three-Phase, 4 Ton, R410A, 81% AFUE, 208/230V
SEER: 14; EER: 11.2; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 100,000; BtuH Heating Output: 80,000; Volts: 208/230; Phase: Three; Motor Type: ECM; Nom. CFM: 1,560; Min. Circuit Amps: 20.2; Refrigerant: R410A; Width: 45-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 456;
Brand: Coleman Mfg #: PCG4B481003X4

Air Conditioning Condensing Unit Thru-The-Wall 12.5 SEER, Single-Phase, 2 TON, R410A B61-346
Air Conditioning Condensing Unit Thru-The-Wall 12.5 SEER, Single-Phase, 2 TON, R410A
Nom. Tons: 2; SEER: 12.5; EER: 11; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Width: 26-1/4"; Height: 28-5/8"; Depth: 18-1/2"; Wt. Lbs.: 180;
Brand: National Comfort Products Mfg #: NCPE-424-1010

Heat Pump 14 SEER, Single-Phase, 2 Ton, R410A B79-085
Heat Pump 14 SEER, Single-Phase, 2 Ton, R410A
SEER: 14; EER: 11.5; Nom. Tons: 2; BtuH Cooling: 23,200; BtuH Heating Input: 23,200; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.2; COP: 4.73; Min. Circuit Amps: 14.7; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29"; Height: 34-1/2"; Depth:…
Brand: Goodman Mfg #: GSZ140251

Single Packaged Heat Pump 14 SEER, Single-Phase, 4 Tons, R410A, Multi-Position B76-805
Single Packaged Heat Pump 14 SEER, Single-Phase, 4 Tons, R410A, Multi-Position
SEER: 14; EER: 11; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 45,600; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 3.6; Nom. CFM: 1,600; Min. Circuit Amps: 34.5; Refrigerant: R410A; Width: 47"; Height: 42-3/4"; Depth: 51"; Wt. Lbs.: 485;
Brand: Goodman Mfg #: GPH1448M41

Air Conditioning Condensing Unit Thru-The-Wall 12.5 SEER, Single-Phase, 2 TON, R410A B61-352
Air Conditioning Condensing Unit Thru-The-Wall 12.5 SEER, Single-Phase, 2 TON, R410A
Nom. Tons: 2; SEER: 12.5; EER: 11; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Width: 30"; Height: 23"; Depth: 22-1/2"; Wt. Lbs.: 180;
Brand: National Comfort Products Mfg #: NCPE-424-4010

Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 4 Ton, R410A B77-535
Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 4 Ton, R410A
SEER: 14; EER: 11.75; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 25.7; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/4"; Height: 33-1/4"; Depth: 35-1/4"; Wt. Lbs.: 215; OEM TXV: B19-659; OEM…
Brand: Evcon Mfg #: RAC14L48B23S

Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 4 Ton, R410A, Southwest Region Only B77-437
Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 4 Ton, R410A, Southwest Region Only
SEER: 14; EER: 11.7; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 25.7; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/4"; Height: 33-1/4"; Depth: 31-3/4"; Wt. Lbs.: 200; OEM TXV: B19-659; OEM…
Brand: Coleman Mfg #: TW4B4821S

Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 2 Ton, R410A, 81% AFUE, LOWNOx B63-655
Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 2 Ton, R410A, 81% AFUE, LOWNOx
SEER: 14; EER: 11.0; Nom. Tons: 2; BtuH Cooling: 23,600; BtuH Heating Input: 50,000; BtuH Heating Output: 41,000; Volts: 208/230V; Phase: Single; Nom. CFM: 800; Min. Circuit Amps: 16.9; Refrigerant: R410A; Width: 35-3/4"; Height: 44"; Depth: 51-1/4"; Wt. Lbs.: 341;
Brand: Coleman Mfg #: PCG4A240502L1

Single Packaged Air Conditioner 14 SEER, Three-Phase, 4 Ton, R410A B64-153
Single Packaged Air Conditioner 14 SEER, Three-Phase, 4 Ton, R410A
SEER: 14; EER: 11.2; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Three; Motor Type: ECM; Nom. CFM: 1,560; Min. Circuit Amps: 20.2; Max. Fuse Size: 30; Refrigerant: R410A; Width: 45-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 431;
Brand: Coleman Mfg #: PCE4B4834

Single Packaged Gas/Electric  Air Conditioner 14 SEER, Single-Phase, 2 Ton, 80% AFUE, R410A, Multi-Position B76-787
Single Packaged Gas/Electric Air Conditioner 14 SEER, Single-Phase, 2 Ton, 80% AFUE, R410A, Multi-Position
SEER: 14; EER: 11.0; Nom. Tons: 2; BtuH Cooling: 23,000; BtuH Heating Input: 60,000; BtuH Heating Output: 48,000; Min. Circuit Amps: 14.6; Refrigerant: R410A; Width: 47"; Height: 32"; Depth: 51"; Wt. Lbs.: 417;
Brand: Goodman Mfg #: GPG1424060M41

Single Packaged Gas/Electric  Air Conditioner 14 SEER, Single-Phase, 4 Ton, 80% AFUE, R410A, Multi-Position B76-797
Single Packaged Gas/Electric Air Conditioner 14 SEER, Single-Phase, 4 Ton, 80% AFUE, R410A, Multi-Position
SEER: 14; EER: 11.0; Nom. Tons: 4; BtuH Cooling: 46,500; BtuH Heating Input: 100,000; BtuH Heating Output: 80,000; Volts: 208/230; Phase: Single; Motor Type: EEM; Min. Circuit Amps: 32.0; Refrigerant: R410A; Width: 47"; Height: 40"; Depth: 51"; Wt. Lbs.: 528;
Brand: Goodman Mfg #: GPG1448100M41

Single Packaged Heat Pump 14 SEER/11.5 EER, Three-Phase, 4 Ton, R410A B62-906
Single Packaged Heat Pump 14 SEER/11.5 EER, Three-Phase, 4 Ton, R410A
Nom. Tons: 4; BtuH Cooling: 46,000; BtuH Heating Input: 45,500; EER: 11.5; HSPF: 8.0; COP: 2.34; Motor Type: Belt Drive; Volts: 208/230; Nom. CFM: 1,460; Min. Circuit Amps: 21.20; Width: 74"; Height: 39-7/8"; Depth: 48-5/16"; Wt. Lbs.: 640;
Brand: Daikin Mfg #: DBH0483B000001S

Air Conditioning Condensing Unit GMC Series, 13 SEER, Single-Phase, 4 Ton, R410A B91-675
Air Conditioning Condensing Unit GMC Series, 13 SEER, Single-Phase, 4 Ton, R410A
SEER: 13; EER: 11.0; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 26.4; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 29"; Height: 36-1/4"; Depth: 29"; Wt. Lbs.: 175; OEM TXV: B14-851;
Brand: Goodman Mfg #: VSX130481

Air Conditioning Condensing Unit 11.2 EER, Three-Phase, 10 Ton, R410A B60-949
Air Conditioning Condensing Unit 11.2 EER, Three-Phase, 10 Ton, R410A
EER: 11.2; Nom. Tons: 10; BtuH Cooling: 120,000; Volts: 460; Phase: 3; Min. Circuit Amps: 22.0; Max. Fuse Size: 35; Liquid Conn.: 5/8"; Suction Fitting: 1-3/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 41-1/2"; Depth: 35-1/2"; Wt. Lbs.: 340;
Brand: Daikin Mfg #: DX11TA1204

Single Packaged Gas/Electric Air Conditioner 14 SEER, Three-Phase, 4 Ton, 81% AFUE, R410A, Multi-Position B79-256
Single Packaged Gas/Electric Air Conditioner 14 SEER, Three-Phase, 4 Ton, 81% AFUE, R410A, Multi-Position
SEER: 14; EER: 11.0; Nom. Tons: 4; BtuH Cooling: 46,500; BtuH Heating Input: 80,000; BtuH Heating Output: 64,800; Volts: 208/230; Phase: Three; Motor Type: EEM; Nom. CFM: 1,525; Min. Circuit Amps: 23.2; Refrigerant: R410A; Width: 47"; Height: 42-3/4"; Depth: 51"; Wt. Lbs.: 523;
Brand: Daikin Mfg #: DP14GM4808043

Thru-the-Wall Heat Pump 13 SEER, Single-Phase, 2 Ton, R410A B61-343
Thru-the-Wall Heat Pump 13 SEER, Single-Phase, 2 Ton, R410A
Nom. Tons: 2; SEER: 13; EER: 11; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Width: 26-7/8"; Height: 38-7/8"; Depth: 18-1/2"; Wt. Lbs.: 190;
Brand: National Comfort Products Mfg #: NHPA-424-5019
FTL Finance