58 Results

1, 3-1/2, 2, 11 to 11.9, HVAC Equipment

Air Conditioning Condensing Unit 13 SEER, Single-Phase, 2 Ton, R410A B61-811
Air Conditioning Condensing Unit 13 SEER, Single-Phase, 2 Ton, R410A
SEER: 13; EER: 11.0; Nom. Tons: 2; BtuH Cooling: 23,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 10.3; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 23"; Height: 27-1/2"; Depth: 23"; Wt. Lbs.: 103; OEM TXV: B18-099;
Brand: Goodman Mfg #: GSX130241

Air Conditioning Condensing Unit 13 SEER, Single-Phase, 2 Ton, R410A B99-212
Air Conditioning Condensing Unit 13 SEER, Single-Phase, 2 Ton, R410A
SEER: 13; EER: 11.0; Nom. Tons: 2; BtuH Cooling: 23,000; Volts: 208-230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 17.6; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 26"; Height: 27-1/2"; Depth: 26"; Wt. Lbs.: 145; OEM TXV: B18-099;
Brand: Amana Mfg #: ASX130241

Air Conditioning Condensing Unit 13 SEER, Single-Phase, 2 Ton, R410A B74-874
Air Conditioning Condensing Unit 13 SEER, Single-Phase, 2 Ton, R410A
SEER: 13; EER: 11.0; Nom. Tons: 2; BtuH Cooling: 23,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 17.8; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 26"; Height: 27-1/2"; Depth: 26"; Wt. Lbs.: 145; OEM TXV: B18-099;
Brand: Amana Mfg #: ANX130241

Air Conditioning Condensing Unit 13 SEER, Single-Phase, 3-1/2 Ton, R410A B98-348
Air Conditioning Condensing Unit 13 SEER, Single-Phase, 3-1/2 Ton, R410A
SEER: 13; EER: 11.0; Nom. Tons: 3-1/2; BtuH Cooling: 42,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 23.6; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 29"; Height: 36-1/4"; Depth: 29"; Wt. Lbs.: 171; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSX130421

Air Conditioning Condensing Unit 13 SEER, Single-Phase, 3-1/2 Ton, R410A B99-215
Air Conditioning Condensing Unit 13 SEER, Single-Phase, 3-1/2 Ton, R410A
SEER: 13; EER: 11.0; Nom. Tons: 3-1/2; BtuH Cooling: 40,000; Volts: 208-230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 23.9; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 29"; Height: 36-1/4"; Depth: 29"; Wt. Lbs.: 206; OEM TXV: B14-851;
Brand: Amana Mfg #: ASX130421

Air Conditioning Condensing Unit 13 SEER, Single-Phase, 3-1/2 Ton, R410A B74-877
Air Conditioning Condensing Unit 13 SEER, Single-Phase, 3-1/2 Ton, R410A
SEER: 13; EER: 11.0; Nom. Tons: 3-1/2; BtuH Cooling: 40,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 23.9; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 29"; Height: 36-1/4"; Depth: 29"; Wt. Lbs.: 206; OEM TXV: B14-851;
Brand: Amana Mfg #: ANX130421

Air Conditioning Condensing Unit 14 SEER, Single-Phase, 2 Ton, R410A B75-907
Air Conditioning Condensing Unit 14 SEER, Single-Phase, 2 Ton, R410A
SEER: 14; EER: 11.5; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 14.2; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 26"; Height: 27-1/2"; Depth: 26"; Wt. Lbs.: 131; OEM TXV: B18-099;
Brand: Goodman Mfg #: GSX140241

Air Conditioning Condensing Unit 14 SEER, Single-Phase, 2 Ton, R410A B76-746
Air Conditioning Condensing Unit 14 SEER, Single-Phase, 2 Ton, R410A
SEER: 14; EER: 11.5; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 17.6; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 26"; Height: 32-1/2"; Depth: 26"; Wt. Lbs.: 153; OEM TXV: B18-099;
Brand: Amana Mfg #: ASX140241

Air Conditioning Condensing Unit GMC Series, 13 SEER, Single-Phase, 2.5 Ton, R410A B61-812
Air Conditioning Condensing Unit GMC Series, 13 SEER, Single-Phase, 2.5 Ton, R410A
SEER: 13; EER: 11; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208-230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 17.6; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 23"; Height: 25-3/4"; Depth: 23"; Wt. Lbs.: 113; OEM TXV: B18-099;
Brand: Goodman Mfg #: VSX130241

Air Conditioning Condensing Unit GMC Series, 13 SEER, Single-Phase, 3.5 Ton, R410A B91-674
Air Conditioning Condensing Unit GMC Series, 13 SEER, Single-Phase, 3.5 Ton, R410A
SEER: 13; EER: 11.0; Nom. Tons: 3-1/2; BtuH Cooling: 42,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 23.9; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 29"; Height: 36-1/4"; Depth: 29"; Wt. Lbs.: 171; OEM TXV: B14-851;
Brand: Goodman Mfg #: VSX130421

Air Conditioning Condensing Unit GMC Series, 14 SEER, Single-Phase, 2 Ton, R410A B75-921
Air Conditioning Condensing Unit GMC Series, 14 SEER, Single-Phase, 2 Ton, R410A
SEER: 14; EER: 11.5; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 10.3; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 26"; Height: 27-1/2"; Depth: 26"; Wt. Lbs.: 131; OEM TXV: B18-099;
Brand: Goodman Mfg #: VSX140241

Air Conditioning Condensing Unit Horizontal Discharge, 13 SEER, Single-Phase, 2 Ton, R410A B75-666
Air Conditioning Condensing Unit Horizontal Discharge, 13 SEER, Single-Phase, 2 Ton, R410A
SEER: 13; EER: 11.5; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 18.3; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 45"; Height: 37-1/4"; Depth: 20"; Wt. Lbs.: 195; OEM TXV: B19-657; OEM TXV for…
Brand: Coleman Mfg #: TCHD24S41S4

Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 2 Ton, R410A B62-069
Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 2 Ton, R410A
SEER: 13; EER: 11.0; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 11.4; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 24"; Height: 26-3/4"; Depth: 24"; Wt. Lbs.: 130; OEM TXV: B20-469; OEM TXV for…
Brand: Coleman Mfg #: TC3B2423S

Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 2 Ton, R410A, Fin Tube B79-328
Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 2 Ton, R410A, Fin Tube
SEER: 13; EER: 11.0; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 14.5; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 24"; Height: 33-1/4"; Depth: 24"; Wt. Lbs.: 118; OEM TXV: B19-657; OEM TXV for…
Brand: Coleman Mfg #: TF3B2421S

Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 3-1/2 Ton, R410A B62-201
Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 3-1/2 Ton, R410A
SEER: 13; EER: 11.25; Nom. Tons: 3-1/2; BtuH Cooling: 42,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 21.1; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 29-1/4"; Height: 30"; Depth: 29-1/4"; Wt. Lbs.: 175; OEM TXV: B19-659; OEM…
Brand: Coleman Mfg #: TC3B4223S

Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 3-1/2 Ton, R410A B61-292
Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 3-1/2 Ton, R410A
SEER: 13; EER: 11.25; Nom. Tons: 3-1/2; BtuH Cooling: 42,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 25.3; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 24"; Height: 30"; Depth: 24"; Wt. Lbs.: 175; OEM TXV: B19-659; OEM TXV for…
Brand: Evcon Mfg #: RAC13L42B23S

Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 3-1/2 Ton, R410A, Fin Tube B79-331
Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 3-1/2 Ton, R410A, Fin Tube
SEER: 13; EER: 11.5; Nom. Tons: 3-1/2; BtuH Cooling: 42,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 23.7; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/4"; Height: 33-1/4"; Depth: 31-3/4"; Wt. Lbs.: 184; OEM TXV: B19-659;…
Brand: Coleman Mfg #: TF3B4221S

Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 2 Ton, R410A, Fin Tube, Southeast Region Only B77-440
Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 2 Ton, R410A, Fin Tube, Southeast Region Only
SEER: 14; EER: 11.7; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 13.6; Max. Fuse Size: 20; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29-1/4"; Height: 30"; Depth: 29-1/4"; Wt. Lbs.: 131; OEM TXV: B19-657; OEM TXV…
Brand: Coleman Mfg #: TF4B2421S

Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 2 Ton, R410A, Southeast & Northern Region Only B61-252
Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 2 Ton, R410A, Southeast & Northern Region Only
SEER: 14; EER: 11.7; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 14.8; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29-1/4"; Height: 26-3/4"; Depth: 29-1/4"; Wt. Lbs.: 135; OEM TXV: B20-469; OEM…
Brand: Coleman Mfg #: TC4B2422S

Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 3-1/2 Ton, R410A, Fin Tube, Southeast Region Only B77-443
Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 3-1/2 Ton, R410A, Fin Tube, Southeast Region Only
SEER: 14; EER: 11.7; Nom. Tons: 3-1/2; BtuH Cooling: 42,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 22.1; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/4"; Height: 39-1/2"; Depth: 31-3/4"; Wt. Lbs.: 230; OEM TXV: B19-659;…
Brand: Coleman Mfg #: TF4B4221S

Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 3-1/2 Ton, R410A, Southeast & Northern Region Only B61-255
Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 3-1/2 Ton, R410A, Southeast & Northern Region Only
SEER: 14; EER: 11.7; Nom. Tons: 3-1/2; BtuH Cooling: 42,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 25.3; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 29-1/4"; Height: 36-1/4"; Depth: 29-1/4"; Wt. Lbs.: 185; OEM TXV: B19-659;…
Brand: Coleman Mfg #: TC4B4222S

Air Conditioning Condensing Unit Up to  15 SEER, Single-Phase, 2 Ton, R410A B76-757
Air Conditioning Condensing Unit Up to 15 SEER, Single-Phase, 2 Ton, R410A
SEER: 14; EER: 11.5; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 14.2; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 26"; Height: 27-1/2"; Depth: 26"; Wt. Lbs.: 126; OEM TXV: B18-099;
Brand: Amana Mfg #: ANX140241

Dual Fuel Packaged Heat Pump 14 SEER, Single-Phase, Single-Stage, 2 Ton, R410A B77-284
Dual Fuel Packaged Heat Pump 14 SEER, Single-Phase, Single-Stage, 2 Ton, R410A
SEER: 14; EER: 11; Nom. Tons: 2; BtuH Cooling: 23,100; BtuH Heating Input: 50,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 1.8; Nom. CFM: 800; Min. Circuit Amps: 15.8; Refrigerant: R410A; Width: 35-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 394;
Brand: Coleman Mfg #: PHG4A240502X1

Dual Fuel Packaged Heat Pump 14 SEER, Single-Phase, Single-Stage, 3.5 Ton, R410A B77-290
Dual Fuel Packaged Heat Pump 14 SEER, Single-Phase, Single-Stage, 3.5 Ton, R410A
SEER: 14; EER: 11; Nom. Tons: 3-1/2; BtuH Cooling: 40,700; BtuH Heating Input: 65,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 2.9; Nom. CFM: 1,400; Min. Circuit Amps: 29.6; Refrigerant: R410A; Width: 45-3/4"; Height: 49"; Depth: 51-1/4"; Wt. Lbs.: 532;
Brand: Coleman Mfg #: PHG4B420652X1
FTL Finance
Powered by Site Search powered by SLI Systems
Select products to compare.
Compare