48 Results

14, 3-1/2, 2, 11 to 11.9, HVAC Equipment

Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 2 Ton, R410A, 81% AFUE B64-190
Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 2 Ton, R410A, 81% AFUE
SEER: 14; EER: 11.0; Nom. Tons: 2; BtuH Cooling: 23,600; BtuH Heating Input: 75,000; BtuH Heating Output: 60,000; Volts: 208/230V; Phase: Single; Nom. CFM: 775; Min. Circuit Amps: 18.1; Refrigerant: R410A; Width: 35-3/4"; Height: 44"; Depth: 51-1/4"; Wt. Lbs.: 336;
Brand: Coleman Mfg #: PCG4A240752X4

Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 3.5 Ton, R410A, 81% AFUE B64-197
Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 3.5 Ton, R410A, 81% AFUE
SEER: 14; EER: 11.2; Nom. Tons: 3-1/2; BtuH Cooling: 41,500; BtuH Heating Input: 100,000; BtuH Heating Output: 80,000; Volts: 208/230V; Phase: Single; Nom. CFM: 1,350; Min. Circuit Amps: 27.0; Refrigerant: R410A; Width: 35-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 402;
Brand: Coleman Mfg #: PCG4A421002X4

Single Packaged Heat Pump 14 SEER, 3-1/2 Ton, Single-Phase, R410A B64-161
Single Packaged Heat Pump 14 SEER, 3-1/2 Ton, Single-Phase, R410A
SEER: 14; EER: 11.6; Nom. Tons: 3-1/2; BtuH Cooling: 42,000; BtuH Heating Input: 39,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 3.6; Nom. CFM: 1,350; Min. Circuit Amps: 27.0; Refrigerant: R410A; Width: 45-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 436;
Brand: Coleman Mfg #: PHE4B4224

Single Packaged Heat Pump 14 SEER, 2 Ton, Single-Phase, R410A B64-158
Single Packaged Heat Pump 14 SEER, 2 Ton, Single-Phase, R410A
SEER: 14; EER: 11.6; Nom. Tons: 2; BtuH Cooling: 25,000; BtuH Heating Input: 23,600; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 3.7; Nom. CFM: 780; Min. Circuit Amps: 18.6; Refrigerant: R410A; Width: 35-3/4"; Height: 44"; Depth: 51-1/4"; Wt. Lbs.: 330;
Brand: Coleman Mfg #: PHE4A2424

Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 2 Ton, R410A, 81% AFUE B64-189
Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 2 Ton, R410A, 81% AFUE
SEER: 14; EER: 11.0; Nom. Tons: 2; BtuH Cooling: 23,600; BtuH Heating Input: 50,000; BtuH Heating Output: 40,000; Volts: 208/230V; Phase: Single; Nom. CFM: 775; Min. Circuit Amps: 16.9; Refrigerant: R410A; Width: 35-3/4"; Height: 44"; Depth: 51-1/4"; Wt. Lbs.: 316;
Brand: Coleman Mfg #: PCG4A240502X4

Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 3.5 Ton, R410A, 81% AFUE B64-196
Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 3.5 Ton, R410A, 81% AFUE
SEER: 14; EER: 11.2; Nom. Tons: 3-1/2; BtuH Cooling: 41,500; BtuH Heating Input: 75,000; BtuH Heating Output: 60,000; Volts: 208/230V; Phase: Single; Nom. CFM: 1,350; Min. Circuit Amps: 27.0; Refrigerant: R410A; Width: 35-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 398;
Brand: Coleman Mfg #: PCG4A420752X4

Single Packaged Air Conditioner 14 SEER, Single-Phase, 2 Ton, R410A B64-142
Single Packaged Air Conditioner 14 SEER, Single-Phase, 2 Ton, R410A
SEER: 14; EER: 11.0; Nom. Tons: 2; BtuH Cooling: 23,600; Volts: 208/230; Phase: Single; Motor Type: ECM; Nom. CFM: 775; Min. Circuit Amps: 18.1; Max. Fuse Size: 25; Refrigerant: R410A; Width: 35-3/4"; Height: 44"; Depth: 51-1/4"; Wt. Lbs.: 307;
Brand: Coleman Mfg #: PCE4A2424

Heat Pump 14 SEER, Single-Phase, 2 Ton, R410A B75-914
Heat Pump 14 SEER, Single-Phase, 2 Ton, R410A
SEER: 14; EER: 11.5; Nom. Tons: 2; BtuH Cooling: 24,000; BtuH Heating Input: 24,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.2; COP: 4.39; Min. Circuit Amps: 10.6; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29"; Height: 34-1/2"; Depth:…
Brand: Goodman Mfg #: GSZ140241

Single Packaged Air Conditioner 14 SEER, Single-Phase, 3-1/2 Ton, R410A B64-145
Single Packaged Air Conditioner 14 SEER, Single-Phase, 3-1/2 Ton, R410A
SEER: 14; EER: 11.2; Nom. Tons: 3-1/2; BtuH Cooling: 41,500; Volts: 208/230; Phase: Single; Motor Type: ECM; Nom. CFM: 1,350; Min. Circuit Amps: 27.0; Max. Fuse Size: 40; Refrigerant: R410A; Width: 35-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 369;
Brand: Coleman Mfg #: PCE4A4224

Heat Pump 14 SEER, Single-Phase, 3-1/2 Ton, R410A B75-917
Heat Pump 14 SEER, Single-Phase, 3-1/2 Ton, R410A
SEER: 14; EER: 11.5; Nom. Tons: 3-1/2; BtuH Cooling: 42,000; BtuH Heating Input: 42,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.2; COP: 4.44; Min. Circuit Amps: 22.0; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 35-1/2"; Height:…
Brand: Goodman Mfg #: GSZ140421

Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 2 Ton, R410A, Southeast & Northern Region Only B61-252
Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 2 Ton, R410A, Southeast & Northern Region Only
SEER: 14; EER: 11.7; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 14.8; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29-1/4"; Height: 26-3/4"; Depth: 29-1/4"; Wt. Lbs.: 135; OEM TXV: B20-469; OEM…
Brand: Coleman Mfg #: TC4B2422S

Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 3-1/2 Ton, R410A, Southeast & Northern Region Only B61-255
Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 3-1/2 Ton, R410A, Southeast & Northern Region Only
SEER: 14; EER: 11.7; Nom. Tons: 3-1/2; BtuH Cooling: 42,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 25.3; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 29-1/4"; Height: 36-1/4"; Depth: 29-1/4"; Wt. Lbs.: 185; OEM TXV: B19-659;…
Brand: Coleman Mfg #: TC4B4222S

Single Packaged Gas/Heat Air Conditioner 14 SEER, Three-Phase, 3-1/2 Ton, R410A, 81% AFUE, 208/230V B64-208
Single Packaged Gas/Heat Air Conditioner 14 SEER, Three-Phase, 3-1/2 Ton, R410A, 81% AFUE, 208/230V
SEER: 14; EER: 11.2; Nom. Tons: 3-1/2; BtuH Cooling: 41,500; BtuH Heating Input: 100,000; BtuH Heating Output: 80,000; Volts: 208/230; Phase: Three; Motor Type: ECM; Nom. CFM: 1,350; Min. Circuit Amps: 20.4; Refrigerant: R410A; Width: 35-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 402;
Brand: Coleman Mfg #: PCG4A421003X4

Single Packaged Gas/Heat Air Conditioner 14 SEER, Three-Phase, 3-1/2 Ton, R410A, 81% AFUE, 208/230V B64-207
Single Packaged Gas/Heat Air Conditioner 14 SEER, Three-Phase, 3-1/2 Ton, R410A, 81% AFUE, 208/230V
SEER: 14; EER: 11.2; Nom. Tons: 3-1/2; BtuH Cooling: 41,500; BtuH Heating Input: 75,000; BtuH Heating Output: 60,000; Volts: 208/230; Phase: Three; Motor Type: ECM; Nom. CFM: 1,350; Min. Circuit Amps: 20.4; Refrigerant: R410A; Width: 35-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 398;
Brand: Coleman Mfg #: PCG4A420753X4

Air Conditioning Condensing Unit 14 SEER, Single-Phase, 2 Ton, R410A B75-907
Air Conditioning Condensing Unit 14 SEER, Single-Phase, 2 Ton, R410A
SEER: 14; EER: 11.5; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 14.2; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 26"; Height: 27-1/2"; Depth: 26"; Wt. Lbs.: 131; OEM TXV: B18-099;
Brand: Goodman Mfg #: GSX140241

Heat Pump LX Series, 14 SEER, Single-Phase, 3-1/2 Ton, R410A B61-298
Heat Pump LX Series, 14 SEER, Single-Phase, 3-1/2 Ton, R410A
SEER: 14; EER: 11.8; Nom. Tons: 3-1/2; BtuH Cooling: 42,000; BtuH Heating Input: 42,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.5; COP: 3.34; Min. Circuit Amps: 26.8; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 38"; Height: 39-1/2";…
Brand: Evcon Mfg #: RHP14L42B24S

Single Packaged Heat Pump 14 SEER, Single-Phase, 2 Tons, R410A, Multi-Position B76-801
Single Packaged Heat Pump 14 SEER, Single-Phase, 2 Tons, R410A, Multi-Position
SEER: 14; EER: 11; Nom. Tons: 2; BtuH Cooling: 24,000; BtuH Heating Input: 23,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 3.6; Nom. CFM: 850; Min. Circuit Amps: 21.8; Refrigerant: R410A; Width: 47"; Height: 34-3/4"; Depth: 51"; Wt. Lbs.: 380;
Brand: Goodman Mfg #: GPH1424M41

Heat Pump 14 SEER, Single-Phase, 2 Ton, R410A B79-085
Heat Pump 14 SEER, Single-Phase, 2 Ton, R410A
SEER: 14; EER: 11.5; Nom. Tons: 2; BtuH Cooling: 23,200; BtuH Heating Input: 23,200; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.2; COP: 4.73; Min. Circuit Amps: 14.7; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29"; Height: 34-1/2"; Depth:…
Brand: Goodman Mfg #: GSZ140251

Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 2 Ton, R410A, 81% AFUE, LOWNOx B63-655
Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 2 Ton, R410A, 81% AFUE, LOWNOx
SEER: 14; EER: 11.0; Nom. Tons: 2; BtuH Cooling: 23,600; BtuH Heating Input: 50,000; BtuH Heating Output: 41,000; Volts: 208/230V; Phase: Single; Nom. CFM: 800; Min. Circuit Amps: 16.9; Refrigerant: R410A; Width: 35-3/4"; Height: 44"; Depth: 51-1/4"; Wt. Lbs.: 341;
Brand: Coleman Mfg #: PCG4A240502L1

Single Packaged Heat Pump 14 SEER, Single-Phase, 3.5 Tons, R410A, Multi-Position B76-804
Single Packaged Heat Pump 14 SEER, Single-Phase, 3.5 Tons, R410A, Multi-Position
SEER: 14; EER: 11; Nom. Tons: 3-1/2; BtuH Cooling: 41,000; BtuH Heating Input: 40,600; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 3.6; Nom. CFM: 1,300; Min. Circuit Amps: 29.6; Refrigerant: R410A; Width: 47"; Height: 34-3/4"; Depth: 51"; Wt. Lbs.: 410;
Brand: Goodman Mfg #: GPH1442M41

Single Packaged Gas/Electric  Air Conditioner 14 SEER, Single-Phase, 2 Ton, 80% AFUE, R410A, Multi-Position B76-787
Single Packaged Gas/Electric Air Conditioner 14 SEER, Single-Phase, 2 Ton, 80% AFUE, R410A, Multi-Position
SEER: 14; EER: 11.0; Nom. Tons: 2; BtuH Cooling: 23,000; BtuH Heating Input: 60,000; BtuH Heating Output: 48,000; Min. Circuit Amps: 14.6; Refrigerant: R410A; Width: 47"; Height: 32"; Depth: 51"; Wt. Lbs.: 417;
Brand: Goodman Mfg #: GPG1424060M41

Single Packaged Gas/Electric  Air Conditioner 14 SEER, Single-Phase, 3-1/2 Ton, 80% AFUE, R410A, Multi-Position B76-794
Single Packaged Gas/Electric Air Conditioner 14 SEER, Single-Phase, 3-1/2 Ton, 80% AFUE, R410A, Multi-Position
SEER: 14; EER: 11.0; Nom. Tons: 3-1/2; BtuH Cooling: 40,000; BtuH Heating Input: 80,000; BtuH Heating Output: 64,000; Volts: 208/230; Phase: Single; Motor Type: EEM; Min. Circuit Amps: 26.8; Refrigerant: R410A; Width: 47"; Height: 32"; Depth: 51"; Wt. Lbs.: 496;
Brand: Goodman Mfg #: GPG1442080M41

Single Packaged Air Conditioner 14 SEER, Single-Phase, 2 Ton, R410A, Multi-Position B76-780
Single Packaged Air Conditioner 14 SEER, Single-Phase, 2 Ton, R410A, Multi-Position
SEER: 14; EER: 11; Nom. Tons: 2; BtuH Cooling: 23,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Nom. CFM: 800; Min. Circuit Amps: 14.6; Max. Fuse Size: 20; Refrigerant: R410A; Width: 47"; Height: 34-3/4"; Depth: 51"; Wt. Lbs.: 319;
Brand: Goodman Mfg #: GPC1424M41

Single Packaged Gas/Electric  Air Conditioner 14 SEER, Single-Phase, 2 Ton, 80% AFUE, R410A, Multi-Position B76-786
Single Packaged Gas/Electric Air Conditioner 14 SEER, Single-Phase, 2 Ton, 80% AFUE, R410A, Multi-Position
SEER: 14; EER: 11.0; Nom. Tons: 2; BtuH Cooling: 23,000; BtuH Heating Input: 40,000; BtuH Heating Output: 31,000; Min. Circuit Amps: 14.6; Refrigerant: R410A; Width: 47"; Height: 32"; Depth: 51"; Wt. Lbs.: 412;
Brand: Goodman Mfg #: GPG1424040M41
FTL Finance
Powered by Site Search powered by SLI Systems
Select products to compare.