77 Results

1, 5, 2, 11 to 11.9, HVAC Equipment

Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 2 Ton, R410A, Southeast & Northern Region Only B61-252
Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 2 Ton, R410A, Southeast & Northern Region Only
SEER: 14; EER: 11.7; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 14.8; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29-1/4"; Height: 26-3/4"; Depth: 29-1/4"; Wt. Lbs.: 135; OEM TXV: B20-469; OEM…
Brand: Coleman Mfg #: TC4B2422S

Gas/Electric Packaged Air Conditioner 14 SEER/11.5 EER, 81% AFUE, Single-Phase, 5 Ton, R410A, Low Heat B61-371
Gas/Electric Packaged Air Conditioner 14 SEER/11.5 EER, 81% AFUE, Single-Phase, 5 Ton, R410A, Low Heat
SEER: 14.0; EER: 11.5; Nom. Tons: 5; BtuH Cooling: 57,000; BtuH Heating Input: 90,000; BtuH Heating Output: 72,900; Volts: 208/230; Phase: Single; Motor Type: Direct Drive; Nom. CFM: 1,660; Min. Circuit Amps: 40.2; Refrigerant: R410A; Width: 74"; Height: 39-7/8"; Depth: 48-5/16"; Wt. Lbs.: 605;
Brand: Daikin Mfg #: DBG0601DL00001S

Gas/Electric Packaged Air Conditioner 14 SEER/11.5 EER, 81% AFUE, Single-Phase, 5 Ton, R410A, High Heat B61-372
Gas/Electric Packaged Air Conditioner 14 SEER/11.5 EER, 81% AFUE, Single-Phase, 5 Ton, R410A, High Heat
SEER: 14.0; EER: 11.5; Nom. Tons: 5; BtuH Cooling: 57,000; BtuH Heating Input: 140,000; BtuH Heating Output: 113,400; Volts: 208/230; Phase: Single; Motor Type: Direct Drive; Nom. CFM: 1,660; Min. Circuit Amps: 40.2; Refrigerant: R410A; Width: 74"; Height: 39-7/8"; Depth: 48-5/16"; Wt. Lbs.: 620;
Brand: Daikin Mfg #: DBG0601DH00001S

Air Conditioning Condensing Unit 13 SEER, Single-Phase, 2 Ton, R410A B61-811
Air Conditioning Condensing Unit 13 SEER, Single-Phase, 2 Ton, R410A
SEER: 13; EER: 11.0; Nom. Tons: 2; BtuH Cooling: 23,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 10.3; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 23"; Height: 27-1/2"; Depth: 23"; Wt. Lbs.: 103; OEM TXV: B18-099;
Brand: Goodman Mfg #: GSX130241

Air Conditioning Condensing Unit GMC Series, 13 SEER, Single-Phase, 2.5 Ton, R410A B61-812
Air Conditioning Condensing Unit GMC Series, 13 SEER, Single-Phase, 2.5 Ton, R410A
SEER: 13; EER: 11; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208-230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 17.6; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 23"; Height: 25-3/4"; Depth: 23"; Wt. Lbs.: 113; OEM TXV: B18-099;
Brand: Goodman Mfg #: VSX130241

Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 2 Ton, R410A B62-069
Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 2 Ton, R410A
SEER: 13; EER: 11.0; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 11.4; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 24"; Height: 26-3/4"; Depth: 24"; Wt. Lbs.: 130; OEM TXV: B20-469; OEM TXV for…
Brand: Coleman Mfg #: TC3B2423S

Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 5 Ton, R410A B62-070
Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 5 Ton, R410A
SEER: 13; EER: 11.0; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 29.1; Max. Fuse Size: 60; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 29-1/4"; Height: 36-1/4"; Depth: 29-1/4"; Wt. Lbs.: 190; OEM TXV: B19-660;…
Brand: Coleman Mfg #: TC3B6022S

Single Packaged Air Conditioner 14 SEER/11.5 EER, Single-Phase, 5 Ton, R410A B62-890
Single Packaged Air Conditioner 14 SEER/11.5 EER, Single-Phase, 5 Ton, R410A
SEER: 14; EER: 11.5; Nom. Tons: 5; BtuH Cooling: 57,000; Volts: 208/230; Phase: Single; Motor Type: Direct Drive; Nom. CFM: 1,640; Min. Circuit Amps: 40.1; Refrigerant: R410A; Width: 74"; Height: 39-7/8"; Depth: 48-5/16"; Wt. Lbs.: 566;
Brand: Daikin Mfg #: DBC0601D000001S

Single Packaged Heat Pump 14 SEER/11.5 EER, Single-Phase, 5 Ton, R410A, Direct Drive B62-893
Single Packaged Heat Pump 14 SEER/11.5 EER, Single-Phase, 5 Ton, R410A, Direct Drive
SEER: 14; EER: 11.5; Nom. Tons: 5; BtuH Cooling: 56,500; BtuH Heating Input: 56,500; Volts: 208/230; Phase: Single; Motor Type: Direct Drive; HSPF: 8.0; COP: 2.3; Nom. CFM: 1,790; Min. Circuit Amps: 40.4; Refrigerant: R410A; Width: 74"; Height: 43-1/2"; Depth: 48-5/16"; Wt. Lbs.: 632;
Brand: Daikin Mfg #: DBH0601D000001S

Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 2 Ton, R410A, 81% AFUE, LOWNOx B63-655
Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 2 Ton, R410A, 81% AFUE, LOWNOx
SEER: 14; EER: 11.0; Nom. Tons: 2; BtuH Cooling: 23,600; BtuH Heating Input: 50,000; BtuH Heating Output: 41,000; Volts: 208/230V; Phase: Single; Nom. CFM: 800; Min. Circuit Amps: 16.9; Refrigerant: R410A; Width: 35-3/4"; Height: 44"; Depth: 51-1/4"; Wt. Lbs.: 341;
Brand: Coleman Mfg #: PCG4A240502L1

Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 5 Ton, R410A, 81% AFUE, LOWNOx B63-658
Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 5 Ton, R410A, 81% AFUE, LOWNOx
SEER: 14; EER: 11.2; Nom. Tons: 5; BtuH Cooling: 56,500; BtuH Heating Input: 65,000; BtuH Heating Output: 53,000; Volts: 208/230V; Phase: Single; Nom. CFM: 2,000; Min. Circuit Amps: 36.5; Refrigerant: R410A; Width: 45-3/4; Height: 50"; Depth: 51-1/4"; Wt. Lbs.: 477;
Brand: Coleman Mfg #: PCG4B600652L1

Single Packaged Air Conditioner 14 SEER, Single-Phase, 2 Ton, R410A B64-142
Single Packaged Air Conditioner 14 SEER, Single-Phase, 2 Ton, R410A
SEER: 14; EER: 11.0; Nom. Tons: 2; BtuH Cooling: 23,600; Volts: 208/230; Phase: Single; Motor Type: ECM; Nom. CFM: 775; Min. Circuit Amps: 18.1; Max. Fuse Size: 25; Refrigerant: R410A; Width: 35-3/4"; Height: 44"; Depth: 51-1/4"; Wt. Lbs.: 307;
Brand: Coleman Mfg #: PCE4A2424

Single Packaged Air Conditioner 14 SEER, Single-Phase, 5 Ton, R410A B64-147
Single Packaged Air Conditioner 14 SEER, Single-Phase, 5 Ton, R410A
SEER: 14; EER: 11.2; Nom. Tons: 5; BtuH Cooling: 56,500; Volts: 208/230; Phase: Single; Motor Type: ECM; Nom. CFM: 1,810; Min. Circuit Amps: 36.5; Max. Fuse Size: 50; Refrigerant: R410A; Width: 45-3/4"; Height: 50"; Depth: 51-1/4"; Wt. Lbs.: 450;
Brand: Coleman Mfg #: PCE4B6024

Single Packaged Heat Pump 14 SEER, 2 Ton, Single-Phase, R410A B64-158
Single Packaged Heat Pump 14 SEER, 2 Ton, Single-Phase, R410A
SEER: 14; EER: 11.6; Nom. Tons: 2; BtuH Cooling: 25,000; BtuH Heating Input: 23,600; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 3.7; Nom. CFM: 780; Min. Circuit Amps: 18.6; Refrigerant: R410A; Width: 35-3/4"; Height: 44"; Depth: 51-1/4"; Wt. Lbs.: 330;
Brand: Coleman Mfg #: PHE4A2424

Single Packaged Heat Pump 14 SEER, 5 Ton, Single-Phase, R410A B64-163
Single Packaged Heat Pump 14 SEER, 5 Ton, Single-Phase, R410A
SEER: 14; EER: 11.6; Nom. Tons: 5; BtuH Cooling: 59,500; BtuH Heating Input: 56,500; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 3.6; Nom. CFM: 1,850; Min. Circuit Amps: 36.5; Refrigerant: R410A; Width: 45-3/4"; Height: 55"; Depth: 51-1/4"; Wt. Lbs.: 485;
Brand: Coleman Mfg #: PHE4B6024

Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 2 Ton, R410A, 81% AFUE B64-189
Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 2 Ton, R410A, 81% AFUE
SEER: 14; EER: 11.0; Nom. Tons: 2; BtuH Cooling: 23,600; BtuH Heating Input: 50,000; BtuH Heating Output: 40,000; Volts: 208/230V; Phase: Single; Nom. CFM: 775; Min. Circuit Amps: 16.9; Refrigerant: R410A; Width: 35-3/4"; Height: 44"; Depth: 51-1/4"; Wt. Lbs.: 316;
Brand: Coleman Mfg #: PCG4A240502X4

Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 2 Ton, R410A, 81% AFUE B64-190
Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 2 Ton, R410A, 81% AFUE
SEER: 14; EER: 11.0; Nom. Tons: 2; BtuH Cooling: 23,600; BtuH Heating Input: 75,000; BtuH Heating Output: 60,000; Volts: 208/230V; Phase: Single; Nom. CFM: 775; Min. Circuit Amps: 18.1; Refrigerant: R410A; Width: 35-3/4"; Height: 44"; Depth: 51-1/4"; Wt. Lbs.: 336;
Brand: Coleman Mfg #: PCG4A240752X4

Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 5 Ton, R410A, 81% AFUE B64-201
Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 5 Ton, R410A, 81% AFUE
SEER: 14; EER: 11.2; Nom. Tons: 5; BtuH Cooling: 56,500; BtuH Heating Input: 65,000; BtuH Heating Output: 52,000; Volts: 208/230V; Phase: Single; Nom. CFM: 1,810; Min. Circuit Amps: 36.5; Refrigerant: R410A; Width: 35-3/4"; Height: 50"; Depth: 51-1/4"; Wt. Lbs.: 469;
Brand: Coleman Mfg #: PCG4B600652X4

Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 5 Ton, R410A, 81% AFUE B64-202
Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 5 Ton, R410A, 81% AFUE
SEER: 14; EER: 11.2; Nom. Tons: 5; BtuH Cooling: 56,500; BtuH Heating Input: 100,000; BtuH Heating Output: 80,000; Volts: 208/230V; Phase: Single; Nom. CFM: 1,810; Min. Circuit Amps: 36.5; Refrigerant: R410A; Width: 35-3/4"; Height: 50"; Depth: 51-1/4"; Wt. Lbs.: 475;
Brand: Coleman Mfg #: PCG4B601002X4

Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 5 Ton, R410A, 81% AFUE B64-203
Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 5 Ton, R410A, 81% AFUE
SEER: 14; EER: 11.2; Nom. Tons: 5; BtuH Cooling: 56,500; BtuH Heating Input: 125,000; BtuH Heating Output: 100,000; Volts: 208/230V; Phase: Single; Nom. CFM: 1,810; Min. Circuit Amps: 36.5; Refrigerant: R410A; Width: 35-3/4"; Height: 50"; Depth: 51-1/4"; Wt. Lbs.: 479;
Brand: Coleman Mfg #: PCG4B601252X4

Packaged Heat Pump 14 SEER, Single-Phase, Single-Stage, 2 Ton, R410A B64-400
Packaged Heat Pump 14 SEER, Single-Phase, Single-Stage, 2 Ton, R410A
SEER: 14; EER: 11.6; Nom. Tons: 2; BtuH Cooling: 25,000; BtuH Heating Input: 75,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 4.5; Nom. CFM: 780; Min. Circuit Amps: 17.4; Refrigerant: R410A; Width: 35-3/4"; Height: 44"; Depth: 51-1/4"; Wt. Lbs.: 357;
Brand: Coleman Mfg #: PHG4A240752X4

Packaged Heat Pump 14 SEER, Single-Phase, Single-Stage, 5 Ton, R410A B64-407
Packaged Heat Pump 14 SEER, Single-Phase, Single-Stage, 5 Ton, R410A
SEER: 14; EER: 11.6; Nom. Tons: 5; BtuH Cooling: 59,500; BtuH Heating Input: 125,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 4.96; Nom. CFM: 1,850; Min. Circuit Amps: 36.5; Refrigerant: R410A; Width: 45-3/4"; Height: 55"; Depth: 51-1/4"; Wt. Lbs.: 550;
Brand: Coleman Mfg #: PHG4B601252X4

Gas/Electric Packaged Air Conditioner 14 SEER, Single-Phase, 2 Ton, 81% AFUE, R410A, Ultra LowNOx B64-920
Gas/Electric Packaged Air Conditioner 14 SEER, Single-Phase, 2 Ton, 81% AFUE, R410A, Ultra LowNOx
SEER: 14; EER: 11; Nom. Tons: 2; BtuH Cooling: 23,000; BtuH Heating Input: 40,000; BtuH Heating Output: 31,000; Volts: 208/230; Phase: Single; Nom. CFM: 800; Min. Circuit Amps: 14.4; Refrigerant: R410A; Width: 47"; Height: 32"; Depth: 51"; Wt. Lbs.: 412;
Brand: Goodman Mfg #: GPU1424040M41

Gas/Electric Packaged Air Conditioner 14 SEER, Single-Phase, 5 Ton, 81% AFUE, R410A, Ultra LowNOx B64-925
Gas/Electric Packaged Air Conditioner 14 SEER, Single-Phase, 5 Ton, 81% AFUE, R410A, Ultra LowNOx
SEER: 16; EER: 11; Nom. Tons: 5; BtuH Cooling: 56,000; BtuH Heating Input: 80,000; BtuH Heating Output: 64,000; Volts: 208/230; Phase: Single; Nom. CFM: 1,700; Min. Circuit Amps: 37.6; Refrigerant: R410A; Width: 47"; Height: 40"; Depth: 51"; Wt. Lbs.: 533;
Brand: Goodman Mfg #: GPU1636080M41
FTL Finance
Powered by Site Search powered by SLI Systems
Select products to compare.