34 Results

2, 12 to 12.8, HVAC Equipment

Air Conditioning Condensing Unit 14 SEER, Single-Phase, 2 Ton, R410A B76-579
Air Conditioning Condensing Unit 14 SEER, Single-Phase, 2 Ton, R410A
SEER: 14; EER: 12.2; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 14.3; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 26"; Height: 27-1/2"; Depth: 26"; Wt. Lbs.: 131; OEM TXV: B18-099;
Brand: Goodman Mfg #: GSX140251

Air Conditioning Condensing Unit 14 SEER, Single-Phase, 2 Ton, R410A B76-747
Air Conditioning Condensing Unit 14 SEER, Single-Phase, 2 Ton, R410A
SEER: 14; EER: 12.2; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 17.6; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 26"; Height: 32-1/2"; Depth: 26"; Wt. Lbs.: 153; OEM TXV: B18-099;
Brand: Amana Mfg #: ASX140251

Air Conditioning Condensing Unit 16 SEER, Single-Phase, 2 Ton, R410A B73-974
Air Conditioning Condensing Unit 16 SEER, Single-Phase, 2 Ton, R410A
SEER: 16; EER: 12.2; Nom. Tons: 2; BtuH Cooling: 23,600; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 18.0; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29"; Height: 32-1/4"; Depth: 29"; Wt. Lbs.: 142; OEM TXV: B18-724;
Brand: Goodman Mfg #: GSX160241

Air Conditioning Condensing Unit 16 SEER, Single-Phase, 2 Ton, R410A B73-981
Air Conditioning Condensing Unit 16 SEER, Single-Phase, 2 Ton, R410A
SEER: 16; EER: 12.2; Nom. Tons: 2; BtuH Cooling: 23,600; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 18.0; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29"; Height: 32-1/2"; Depth: 29"; Wt. Lbs.: 163; OEM TXV: B18-724;
Brand: Amana Mfg #: ASX160241

Air Conditioning Condensing Unit 16 SEER, Two-Stage, Single-Phase, 2 Ton, R410A B91-179
Air Conditioning Condensing Unit 16 SEER, Two-Stage, Single-Phase, 2 Ton, R410A
SEER: 16; EER: 12.2; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 15.7; Max. Fuse Size: 20; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29-1/4"; Height: 32-1/2"; Depth: 29-1/4"; Wt. Lbs.: 180; OEM TXV: B18-099;
Brand: Amana Mfg #: ASXC160241

Air Conditioning Condensing Unit GMC Series, 14 SEER, Single-Phase, 2 Ton, R410A B76-583
Air Conditioning Condensing Unit GMC Series, 14 SEER, Single-Phase, 2 Ton, R410A
SEER: 14; EER: 12.2; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 17.6; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 26"; Height: 32-1/2"; Depth: 26"; Wt. Lbs.: 136; OEM TXV: B18-099;
Brand: Goodman Mfg #: VSX140251

Air Conditioning Condensing Unit Horizontal Discharge, 14 SEER, Single-Phase, 2 Ton, R410A B60-174
Air Conditioning Condensing Unit Horizontal Discharge, 14 SEER, Single-Phase, 2 Ton, R410A
SEER: 14; EER: 12.2; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 18.3; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 45"; Height: 37-1/4"; Depth: 20"; Wt. Lbs.: 195; OEM TXV: B19-657; OEM TXV for…
Brand: Coleman Mfg #: TCHE24S41S1

Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 2 Ton, R410A B62-869
Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 2 Ton, R410A
SEER: 13; EER: 12.5; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 11.4; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 24"; Height: 26-3/4"; Depth: 24"; Wt. Lbs.: 130; OEM TXV: B20-469; OEM TXV for…
Brand: Evcon Mfg #: RAC13L24B24S

Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 2 Ton, R407C B79-030
Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 2 Ton, R407C
SEER: 14; EER: 12.2; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 14.2; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R407C; Width: 29-1/4"; Height: 30"; Depth: 29-1/4"; Wt. Lbs.: 135; OEM TXV: B15-137; OEM TXV…
Brand: Evcon Mfg #: GAW14L24C23S

Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 2 Ton, R410A B61-294
Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 2 Ton, R410A
SEER: 14; EER: 12.00; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 14.8; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29-1/4"; Height: 26-3/4"; Depth: 29-1/4"; Wt. Lbs.: 145; OEM TXV: B20-469; OEM…
Brand: Evcon Mfg #: RAC14L24B23S

Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 2 Ton, R410A, Southwest Region Only B62-066
Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 2 Ton, R410A, Southwest Region Only
SEER: 14; EER: 12.2; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 14.8; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29-1/4"; Height: 30"; Depth: 29-1/4"; Wt. Lbs.: 135; OEM TXV: B20-469; OEM TXV…
Brand: Coleman Mfg #: TW4B2422S

Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 2 Ton, R410A, Southwest Region Only B77-433
Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 2 Ton, R410A, Southwest Region Only
SEER: 14; EER: 12.2; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 13.6; Max. Fuse Size: 20; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29-1/4"; Height: 30"; Depth: 29-1/4"; Wt. Lbs.: 135; OEM TXV: B19-657; OEM TXV…
Brand: Coleman Mfg #: TW4B2421S

Air Conditioning Condensing Unit LX Series, 17 SEER, Single-Phase, 2 Ton, R410A B78-425
Air Conditioning Condensing Unit LX Series, 17 SEER, Single-Phase, 2 Ton, R410A
SEER: 17; EER: 12.75; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 16.4; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29-1/4"; Height: 30"; Depth: 29-1/4"; Wt. Lbs.: 160; OEM TXV: B19-657;
Brand: Evcon Mfg #: RAC17L24B21S

Air Conditioning Condensing Unit Thru-The-Wall 14 SEER, Single-Phase, 2 TON, R410A B61-355
Air Conditioning Condensing Unit Thru-The-Wall 14 SEER, Single-Phase, 2 TON, R410A
Nom. Tons: 2; SEER: 14; EER: 12; Max. Fuse Size: 20; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Width: 26-7/8"; Height: 38-7/8"; Depth: 18-1/2"; Wt. Lbs.: 180;
Brand: National Comfort Products Mfg #: NCPE-424-5010

Air Conditioning Condensing Unit Up to  15 SEER, Single-Phase, 2 Ton, R410A B76-758
Air Conditioning Condensing Unit Up to 15 SEER, Single-Phase, 2 Ton, R410A
SEER: 14; EER: 12.2; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 17.6; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 26"; Height: 32-1/2"; Depth: 26"; Wt. Lbs.: 136; OEM TXV: B18-099;
Brand: Amana Mfg #: ANX140251

Dual Fuel Packaged Heat Pump 16 SEER, Single-Phase, Single-Stage, 2 Ton, R410A B60-877
Dual Fuel Packaged Heat Pump 16 SEER, Single-Phase, Single-Stage, 2 Ton, R410A
SEER: 16; EER: 12.5; Nom. Tons: 2; BtuH Cooling: 23,400; BtuH Heating Input: 50,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.2; COP: 3.7; Nom. CFM: 800; Min. Circuit Amps: 17.9; Refrigerant: R410A; Width: 35-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 394;
Brand: Coleman Mfg #: PHG6A240502X1

Gas/Electric Packaged Air Conditioner 16 SEER, Single-Phase, 2 Ton, 81% AFUE, R410A, Multi-Position B77-203
Gas/Electric Packaged Air Conditioner 16 SEER, Single-Phase, 2 Ton, 81% AFUE, R410A, Multi-Position
SEER: 16; EER: 12.0; Nom. Tons: 2; BtuH Cooling: 22,800; BtuH Heating Input: 60,000; BtuH Heating Output: 47,000; Volts: 208/230; Phase: 1; Motor Type: ECM; Nom. CFM: 800; Min. Circuit Amps: 20.0; Refrigerant: R410A; Width: 47"; Height: 34-3/4"; Depth: 51"; Wt. Lbs.: 370;
Brand: Amana Mfg #: APG1624060M41

Heat Pump 16 SEER, Two-Stage, Single-Phase, 2 Ton, R410A B91-186
Heat Pump 16 SEER, Two-Stage, Single-Phase, 2 Ton, R410A
SEER: 16; EER: 12.5; Nom. Tons: 2; BtuH Cooling: 24,000; BtuH Heating Input: 24,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 9.5; COP: 4.74; Min. Circuit Amps: 15.8; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29"; Height: 38-1/4"; Depth:…
Brand: Amana Mfg #: ASZC160241

Heat Pump 16 SEER, Two-Stage, Single-Phase, 2 Tons, R410A B91-224
Heat Pump 16 SEER, Two-Stage, Single-Phase, 2 Tons, R410A
SEER: 16; EER: 12.5; Nom. Tons: 2; BtuH Cooling: 24,000; BtuH Heating Input: 24,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.5; COP: 4.74; Min. Circuit Amps: 15.8; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29"; Height: 38-1/4"; Depth:…
Brand: Goodman Mfg #: DSZC160241

Heat Pump LX Series, 14 SEER, Single-Phase, 2 Ton, R410A B78-391
Heat Pump LX Series, 14 SEER, Single-Phase, 2 Ton, R410A
SEER: 14; EER: 12.75; Nom. Tons: 2; BtuH Cooling: 23,800; BtuH Heating Input: 24,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.2; COP: 3.96; Min. Circuit Amps: 15.4; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29-1/4"; Height: 36-1/4";…
Brand: Coleman Mfg #: TH4B2421S

Heat Pump LX Series, 14 SEER, Single-Phase, 2 Ton, R410A B62-882
Heat Pump LX Series, 14 SEER, Single-Phase, 2 Ton, R410A
SEER: 14; EER: 12.0; Nom. Tons: 2; BtuH Cooling: 25,000; BtuH Heating Input: 22,200; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 9.0; COP: 3.68; Min. Circuit Amps: 14.1; Max. Fuse Size: 20; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 24"; Height: 33-1/4"; Depth:…
Brand: Evcon Mfg #: REP14L24B21S

Heat Pump LX Series, 14 SEER, Single-Phase, 2 Ton, R410A B62-863
Heat Pump LX Series, 14 SEER, Single-Phase, 2 Ton, R410A
SEER: 14; EER: 12.0; Nom. Tons: 2; BtuH Cooling: 25,000; BtuH Heating Input: 22,200; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 9.0; COP: 3.68; Min. Circuit Amps: 14.1; Max. Fuse Size: 20; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 24"; Height: 33-1/4"; Depth:…
Brand: Coleman Mfg #: TE4B2421S

Single Packaged Air Conditioner 14 SEER, Single-Phase, 2 Ton, R410A, Horizontal B90-040
Single Packaged Air Conditioner 14 SEER, Single-Phase, 2 Ton, R410A, Horizontal
SEER: 14; EER: 12; Nom. Tons: 2; BtuH Cooling: 23,600; Volts: 208/230; Phase: Single; Motor Type: EEM; Nom. CFM: 875; Min. Circuit Amps: 15.0; Max. Fuse Size: 20; Refrigerant: R410A; Width: 66"; Height: 30-1/2"; Depth: 33"; Wt. Lbs.: 315;
Brand: Goodman Mfg #: GPC1424H41

Single Packaged Air Conditioner 14 SEER, Single-Phase, 2 Ton, R410A, Horizontal B74-926
Single Packaged Air Conditioner 14 SEER, Single-Phase, 2 Ton, R410A, Horizontal
SEER: 14; EER: 12; Nom. Tons: 2; BtuH Cooling: 23600; Volts: 208/230; Phase: Single; Motor Type: ECM; Nom. CFM: 875; Min. Circuit Amps: 22; Max. Fuse Size: 35; Refrigerant: R410A; Width: 66"; Height: 30-1/2"; Depth: 33"; Wt. Lbs.: 305;
Brand: Amana Mfg #: APC1424H41
FTL Finance
Powered by Site Search powered by SLI Systems
Select products to compare.
Compare