UNITED STATES, 1, 3, 2, HVAC Equipment

Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 2 Ton, R410A B65-961
Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 2 Ton, R410A
SEER2: 14.3; Nom. Tons: 2; BtuH Cooling: 23,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 11.2; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 26"; Height: 32-1/2"; Depth: 26"; Wt. Lbs.: 138; OEM TXV: B18-099;
Brand: Goodman Mfg #: GSXN402410

Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 3 Ton, R410A B65-963
Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 3 Ton, R410A
SEER2: 14.3; Nom. Tons: 3; BtuH Cooling: 34,800; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 21.0; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 35-3/4"; Depth: 35-1/2"; Wt. Lbs.: 188; OEM TXV: B14-850;
Brand: Goodman Mfg #: GSXN403610

Single Packaged Gas/Heat Air Conditioner LX Series, 16 SEER, Single-Phase, 3 Ton, R410A, 81% AFUE B64-226
Single Packaged Gas/Heat Air Conditioner LX Series, 16 SEER, Single-Phase, 3 Ton, R410A, 81% AFUE
SEER: 16; EER: 12.0; Nom. Tons: 3; BtuH Cooling: 35,800; BtuH Heating Input: 75,000; BtuH Heating Output: 60,000; Volts: 208/230; Phase: Single; Nom. CFM: 1,200; Min. Circuit Amps: 23.2; Refrigerant: R410A; Width: 35-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 466;
Brand: Coleman Mfg #: PCG6A360752X4

Heat Pump GSZB4 Series, 14.3 SEER2, 7.5HSPF2, 3 Ton, R410A B66-328
Heat Pump GSZB4 Series, 14.3 SEER2, 7.5HSPF2, 3 Ton, R410A
SEER2: 14.3; Nom. Tons: 3; BtuH Cooling: 36,000; BtuH Heating Input: 36,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF2: 7.5; COP: 3.5; Min. Circuit Amps: 21.0; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 39-10/16"; Depth:…
Brand: Goodman Mfg #: GSZB403610

Single Packaged Gas/Heat Air Conditioner LX Series, 16 SEER, Single-Phase, 2 Ton, R410A, 81% AFUE B64-224
Single Packaged Gas/Heat Air Conditioner LX Series, 16 SEER, Single-Phase, 2 Ton, R410A, 81% AFUE
SEER: 16; EER: 12.5; Nom. Tons: 2; BtuH Cooling: 24,000; BtuH Heating Input: 50,000; BtuH Heating Output: 40,000; Volts: 208/230; Phase: Single; Nom. CFM: 750; Min. Circuit Amps: 16.1; Refrigerant: R410A; Width: 35-3/4"; Height: 44"; Depth: 51-1/4"; Wt. Lbs.: 372;
Brand: Coleman Mfg #: PCG6A240502X4

Heat Pump GSZB4 Series, 14.3 SEER2, 7.5HSPF2, 2 Ton, R410A B66-326
Heat Pump GSZB4 Series, 14.3 SEER2, 7.5HSPF2, 2 Ton, R410A
SEER2: 14.3; Nom. Tons: 2; BtuH Cooling: 24,000; BtuH Heating Input: 24,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF2: 7.5; COP: 3.6; Min. Circuit Amps: 11.5; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29"; Height: 35-11/16"; Depth: 29";…
Brand: Goodman Mfg #: GSZB402410

Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 2 Ton, R410A B65-957
Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 2 Ton, R410A
SEER2: 14.3; Nom. Tons: 2; BtuH Cooling: 23,600; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 15.4; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29"; Height: 32"; Depth: 29"; Wt. Lbs.: 151; OEM TXV: B18-099;
Brand: Goodman Mfg #: GSXM402410

Single Packaged Gas/Heat Air Conditioner LX Series, 16 SEER, Single-Phase, 2 Ton, R410A, 81% AFUE B64-225
Single Packaged Gas/Heat Air Conditioner LX Series, 16 SEER, Single-Phase, 2 Ton, R410A, 81% AFUE
SEER: 16; EER: 12.5; Nom. Tons: 2; BtuH Cooling: 24,000; BtuH Heating Input: 75,000; BtuH Heating Output: 60,000; Volts: 208/230; Phase: Single; Nom. CFM: 750; Min. Circuit Amps: 16.1; Refrigerant: R410A; Width: 35-3/4"; Height: 44"; Depth: 51-1/4"; Wt. Lbs.: 382;
Brand: Coleman Mfg #: PCG6A240752X4

Heat Pump 15.2 SEER2, Single-Phase, 3 Ton, R410A B65-701
Heat Pump 15.2 SEER2, Single-Phase, 3 Ton, R410A
SEER2: 15.2; Nom. Tons: 3; BtuH Cooling: 36,000; BtuH Heating Input: 36,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF2: 7.8; Min. Circuit Amps: 22.8; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 39-1/2"; Depth: 35-1/2"; Wt.…
Brand: Goodman Mfg #: GSZH503610

Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 3 Ton, R410A B65-952
Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 3 Ton, R410A
SEER2: 14.3; Nom. Tons: 3; BtuH Cooling: 34,600; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 18.6; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 39-1/2"; Depth: 35-1/2"; Wt. Lbs.: 224; OEM TXV: B14-850;
Brand: Goodman Mfg #: GSXB403610

Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 2 Ton, R410A B65-950
Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 2 Ton, R410A
SEER2: 14.3; Nom. Tons: 2; BtuH Cooling: 23,600; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 15.3; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29"; Height: 32"; Depth: 29"; Wt. Lbs.: 169; OEM TXV: B18-099;
Brand: Goodman Mfg #: GSXB402410

Heat Pump 15.2 SEER2, Single-Phase, 2 Ton, R410A B65-699
Heat Pump 15.2 SEER2, Single-Phase, 2 Ton, R410A
SEER2: 15.2; Nom. Tons: 2; BtuH Cooling: 24,000; BtuH Heating Input: 24,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF2: 7.8; Min. Circuit Amps: 15.3; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 35-1/2"; Height: 35-3/4"; Depth: 35-1/2"; Wt.…
Brand: Goodman Mfg #: GSZH502410

Air Conditioning Condensing Unit 17.2 SEER2, Two-Stage, Single-Phase, 3 Ton, R410A B65-723
Air Conditioning Condensing Unit 17.2 SEER2, Two-Stage, Single-Phase, 3 Ton, R410A
SEER2: 17.2; Nom. Tons: 3; BtuH Cooling: 36,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 24.1; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 39-1/2"; Depth: 35-1/2"; Wt. Lbs.: 216; OEM TXV: B14-850;
Brand: Goodman Mfg #: GSXC703610

Heat Pump LX Series, 14 SEER, Single-Phase, 3 Ton, R410A B61-149
Heat Pump LX Series, 14 SEER, Single-Phase, 3 Ton, R410A
SEER: 14; EER: 12.75; Nom. Tons: 3; BtuH Cooling: 34,000; BtuH Heating Input: 36,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.2; COP: 3.72; Min. Circuit Amps: 21.99; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 38"; Height: 39-1/2";…
Brand: Coleman Mfg #: TH4B3622S

Heat Pump 16 SEER, Single-Phase, 3 Ton, R410A B61-218
Heat Pump 16 SEER, Single-Phase, 3 Ton, R410A
SEER: 16; EER: 13; Nom. Tons: 3; BtuH Cooling: 36,000; BtuH Heating Input: 36,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.0; COP: 3.36; Min. Circuit Amps: 22.0; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 35-1/4"; Height: 39-1/2";…
Brand: Coleman Mfg #: CH6B3621S

Single Packaged Heat Pump 14 SEER, 3 Ton, Single-Phase, R410A B64-160
Single Packaged Heat Pump 14 SEER, 3 Ton, Single-Phase, R410A
SEER: 14; EER: 11.6; Nom. Tons: 3; BtuH Cooling: 35,800; BtuH Heating Input: 34,800; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 3.6; Nom. CFM: 1,150; Min. Circuit Amps: 23.9; Refrigerant: R410A; Width: 45-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 420;
Brand: Coleman Mfg #: PHE4B3624

Heat Pump 16 SEER, Single-Phase, 2 Ton, R410A B61-216
Heat Pump 16 SEER, Single-Phase, 2 Ton, R410A
SEER: 16; EER: 13; Nom. Tons: 2; BtuH Cooling: 24,000; BtuH Heating Input: 24,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.0; COP: 3.22; Min. Circuit Amps: 15.5; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 35-1/4"; Height: 39-1/2";…
Brand: Coleman Mfg #: CH6B2421S

Air Conditioning Condensing Unit Echelon™ 19 SEER, Single-Phase, 2 Ton, R410A B60-665
Air Conditioning Condensing Unit Echelon™ 19 SEER, Single-Phase, 2 Ton, R410A
SEER: 19; EER: 15.5; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 15.3; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 38-1/4"; Height: 40-1/4"; Depth: 34-1/2"; Wt. Lbs.: 195; OEM TXV: B20-469; OEM…
Brand: Coleman Mfg #: AC19B2421S

Air Conditioning Condensing Unit Echelon™ 19 SEER, Single-Phase, 3 Ton, R410A B60-666
Air Conditioning Condensing Unit Echelon™ 19 SEER, Single-Phase, 3 Ton, R410A
SEER: 19; EER: 14.75; Nom. Tons: 3; BtuH Cooling: 36,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 21.4; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 38-1/4"; Height: 46-1/2"; Depth: 34-1/2"; Wt. Lbs.: 265; OEM TXV: B19-657; OEM…
Brand: Coleman Mfg #: AC19B3621S

Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 3 Ton, R410A, 81% AFUE B64-195
Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 3 Ton, R410A, 81% AFUE
SEER: 14; EER: 11.8; Nom. Tons: 3; BtuH Cooling: 35,800; BtuH Heating Input: 100,000; BtuH Heating Output: 80,000; Volts: 208/230V; Phase: Single; Nom. CFM: 1,165; Min. Circuit Amps: 25.5; Refrigerant: R410A; Width: 35-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 383;
Brand: Coleman Mfg #: PCG4A361002X4

Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 2 Ton, R410A, 81% AFUE B64-190
Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 2 Ton, R410A, 81% AFUE
SEER: 14; EER: 11.0; Nom. Tons: 2; BtuH Cooling: 23,600; BtuH Heating Input: 75,000; BtuH Heating Output: 60,000; Volts: 208/230V; Phase: Single; Nom. CFM: 775; Min. Circuit Amps: 18.1; Refrigerant: R410A; Width: 35-3/4"; Height: 44"; Depth: 51-1/4"; Wt. Lbs.: 336;
Brand: Coleman Mfg #: PCG4A240752X4

Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 3 Ton, R410A B62-200
Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 3 Ton, R410A
SEER: 13; EER: 11.0; Nom. Tons: 3; BtuH Cooling: 36,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 19.8; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 24"; Height: 33-1/4"; Depth: 24"; Wt. Lbs.: 165; OEM TXV: B19-657; OEM TXV for…
Brand: Coleman Mfg #: TC3B3623S

Heat Pump 16 SEER, Two-Stage, Single-Phase, 3 Tons, R410A B61-612
Heat Pump 16 SEER, Two-Stage, Single-Phase, 3 Tons, R410A
SEER: 16; EER: 13.0; Nom. Tons: 3; BtuH Cooling: 36,000; BtuH Heating Input: 36,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.0; COP: 4.4; Min. Circuit Amps: 19.5; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 40"; Depth:…
Brand: Goodman Mfg #: GSZC160361

Heat Pump 18 SEER, Two-Stage, Single-Phase, 2 Tons, R410A B61-607
Heat Pump 18 SEER, Two-Stage, Single-Phase, 2 Tons, R410A
SEER: 18; EER: 14.0; Nom. Tons: 2; BtuH Cooling: 23,800; BtuH Heating Input: 23,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 10.0; COP: 5.65; Min. Circuit Amps: 15.3; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 40"; Depth:…
Brand: Goodman Mfg #: GSZC180241