93 Results

14, 4, HVAC Equipment

Single Packaged Gas/Heat Air Conditioner LX Series, 14 SEER, Single-Phase, 4 Ton, R410A, 81% AFUE B61-587
Single Packaged Gas/Heat Air Conditioner LX Series, 14 SEER, Single-Phase, 4 Ton, R410A, 81% AFUE
SEER: 14; EER: 11.2; Nom. Tons: 4; BtuH Cooling: 45,500; BtuH Heating Input: 100,000; BtuH Heating Output: 80,000; Volts: 208/230V; Phase: Single; Nom. CFM: 1,600; Min. Circuit Amps: 34.4; Refrigerant: R410A; Width: 45-3/4"; Height: 49"; Depth: 51"; Wt. Lbs.: 473;
Brand: Coleman Mfg #: PCG4B481252X2

Manufactured Housing Air Conditioning Condensing Unit 14 SEER AccuCharge® 4 Ton, R410A B60-919
Manufactured Housing Air Conditioning Condensing Unit 14 SEER AccuCharge® 4 Ton, R410A
Nom. Tons: 4; Min. Circuit Amps: 26.2; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Width: 35-1/2"; Height: 43"; Depth: 35-1/2"; Wt. Lbs.: 212; SEER: 14;
Brand: Maytag Mfg #: RSCQ484

Manufactured Housing Heat Pump 14 SEER, 4 Ton, Single-Phase, R410A, Sweat Fit B60-942
Manufactured Housing Heat Pump 14 SEER, 4 Ton, Single-Phase, R410A, Sweat Fit
Nom. Tons: 4; Min. Circuit Amps: 26.3; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Width: 35-1/2"; Height: 47"; Depth: 35-1/2"; Wt. Lbs.: 247; SEER: 14;
Brand: Maytag Mfg #: RSHS484

Manufactured Housing Heat Pump 14 SEER, 4 Ton, Single-Phase, R410A, Quick Connect B60-937
Manufactured Housing Heat Pump 14 SEER, 4 Ton, Single-Phase, R410A, Quick Connect
Nom. Tons: 4; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Width: 35-1/2"; Height: 47"; Depth: 35-1/2"; Wt. Lbs.: 234; SEER: 14;
Brand: Maytag Mfg #: RSHQ484

Manufactured Housing Air Conditioning Condensing Unit 14 SEER Sweat Fit 4 Ton, R410A B60-931
Manufactured Housing Air Conditioning Condensing Unit 14 SEER Sweat Fit 4 Ton, R410A
Nom. Tons: 4; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Width: 35-1/2"; Height: 43"; Depth: 35-1/2"; Wt. Lbs.: 206; SEER: 14;
Brand: Maytag Mfg #: RSCS484

Heat Pump GMC Series, 13 SEER, Single-Phase, 5 Ton, R410A B75-679
Heat Pump GMC Series, 13 SEER, Single-Phase, 5 Ton, R410A
SEER: 14; EER: 11.5; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 48,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.5; COP: 4.39; Min. Circuit Amps: 26.4; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 35-1/2"; Height: 34-1/2";…
Brand: Goodman Mfg #: VSZ140491

Single Packaged Gas/Heat Air Conditioner 16 SEER, Three-Phase, 4 Ton, R410A, 81% AFUE B78-082
Single Packaged Gas/Heat Air Conditioner 16 SEER, Three-Phase, 4 Ton, R410A, 81% AFUE
SEER: 14; EER: 11; Nom. Tons: 4; BtuH Cooling: 45,500; BtuH Heating Input: 125,000; BtuH Heating Output: 100,000; Nom. CFM: 1,600; Min. Circuit Amps: 24.2; Width: 46; Height: 53; Depth: 51-1/4"; Wt. Lbs.: 533;
Brand: Coleman Mfg #: PCG4B481253X1

Dual Fuel Packaged Heat Pump 14 SEER, Single-Phase, Single-Stage, 4 Ton, R410A B77-294
Dual Fuel Packaged Heat Pump 14 SEER, Single-Phase, Single-Stage, 4 Ton, R410A
SEER: 14; EER: 11; Nom. Tons: 4; BtuH Cooling: 45,500; BtuH Heating Input: 125,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 3.5; Nom. CFM: 1,600; Min. Circuit Amps: 34.6; Refrigerant: R410A; Width: 45-3/4"; Height: 53"; Depth: 51-1/4"; Wt. Lbs.: 564;
Brand: Coleman Mfg #: PHG4B481252X1

Dual Fuel Packaged Heat Pump 14 SEER, Single-Phase, Single-Stage, 4 Ton, R410A B77-292
Dual Fuel Packaged Heat Pump 14 SEER, Single-Phase, Single-Stage, 4 Ton, R410A
SEER: 14; EER: 11; Nom. Tons: 4; BtuH Cooling: 45,500; BtuH Heating Input: 65,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 3.5; Nom. CFM: 1,600; Min. Circuit Amps: 34.6; Refrigerant: R410A; Width: 45-3/4"; Height: 53"; Depth: 51-1/4"; Wt. Lbs.: 551;
Brand: Coleman Mfg #: PHG4B480652X1

Dual Fuel Packaged Heat Pump 14 SEER, Single-Phase, Single-Stage, 4 Ton, R410A B77-293
Dual Fuel Packaged Heat Pump 14 SEER, Single-Phase, Single-Stage, 4 Ton, R410A
SEER: 14; EER: 11; Nom. Tons: 4; BtuH Cooling: 45,500; BtuH Heating Input: 100,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 3.5; Nom. CFM: 1,600; Min. Circuit Amps: 34.6; Refrigerant: R410A; Width: 45-3/4"; Height: 53"; Depth: 51-1/4"; Wt. Lbs.: 559;
Brand: Coleman Mfg #: PHG4B481002X1

Manufactured Housing Air Conditioning Condensing Unit 14 SEER, 4 Ton, Single-Phase, R410A B78-550
Manufactured Housing Air Conditioning Condensing Unit 14 SEER, 4 Ton, Single-Phase, R410A
Nom. Tons: 4; Min. Circuit Amps: 25.7; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Width: 35-1/4"; Height: 33-1/4"; Depth: 31-1/4"; Wt. Lbs.: 200; SEER: 14;
Brand: Coleman Mfg #: QC4B48B21S

Manufactured Housing Air Conditioning Condensing Unit 14 SEER, 4 Ton, Single-Phase, R410A B78-556
Manufactured Housing Air Conditioning Condensing Unit 14 SEER, 4 Ton, Single-Phase, R410A
Nom. Tons: 4; Min. Circuit Amps: 25.7; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Width: 35-1/4"; Height: 33-1/4"; Depth: 31-3/4"; Wt. Lbs.: 200; SEER: 14;
Brand: Coleman Mfg #: QW4B48B21S

Air Conditioning Condensing Unit GMC Series, 14 SEER, Single-Phase, 4 Ton, R410A B75-925
Air Conditioning Condensing Unit GMC Series, 14 SEER, Single-Phase, 4 Ton, R410A
SEER: 14; EER: 11.7; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 26.2; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 36-1/4"; Depth: 35-1/2"; Wt. Lbs.: 220; OEM TXV: B14-851;
Brand: Goodman Mfg #: VSX140481

Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 4 Ton, R410A, 81% AFUE B76-978
Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 4 Ton, R410A, 81% AFUE
SEER: 14; Nom. Tons: 4; BtuH Cooling: 45,500; BtuH Heating Input: 125,000; BtuH Heating Output: 100,000; Nom. CFM: 1,600; Min. Circuit Amps: 34.7; Refrigerant: R410A; Width: 45-3/4"; Height: 49"; Depth: 51"; Wt. Lbs.: 533;
Brand: Coleman Mfg #: PCG4B481252X1

Single Packaged Air Conditioner 14 SEER, Single-Phase, 4 Ton, R410A, Horizontal B74-930
Single Packaged Air Conditioner 14 SEER, Single-Phase, 4 Ton, R410A, Horizontal
SEER: 14; EER: 12; Nom. Tons: 4; BtuH Cooling: 46000; Volts: 208/230; Phase: Single; Motor Type: ECM; Nom. CFM: 1600; Min. Circuit Amps: 32; Max. Fuse Size: 50; Refrigerant: R410A; Width: 66"; Height: 38-1/2"; Depth: 33"; Wt. Lbs.: 370;
Brand: Amana Mfg #: APC1448H41

Heat Pump Up To 15 SEER, Single-Phase, 4 Ton, R410A B78-387
Heat Pump Up To 15 SEER, Single-Phase, 4 Ton, R410A
SEER: 14; EER: 11.5; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 48,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 9.0; COP: 4.39; Min. Circuit Amps: 26.0; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 34-1/2";…
Brand: Amana Mfg #: ASZ140491

Heat Pump 14 SEER, Single-Phase, 4 Ton, R410A B78-388
Heat Pump 14 SEER, Single-Phase, 4 Ton, R410A
SEER: 14; EER: 11.5; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 48,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.5; COP: 4.39; Min. Circuit Amps: 26.0; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 34-1/2";…
Brand: Amana Mfg #: ANZ140491

Air Conditioning Condensing Unit Up to  15 SEER, Single-Phase, 4 Ton, R410A B76-764
Air Conditioning Condensing Unit Up to 15 SEER, Single-Phase, 4 Ton, R410A
SEER: 14; EER: 11.7; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 26.2; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 36-1/4"; Depth: 35-1/2"; Wt. Lbs.: 220; OEM TXV: B14-851;
Brand: Amana Mfg #: ANX140481

Heat Pump 14 SEER, Single-Phase, 4 Ton, R410A B76-778
Heat Pump 14 SEER, Single-Phase, 4 Ton, R410A
SEER: 14; EER: 11.5; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 48,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 9.0; COP: 4.72; Min. Circuit Amps: 24.4; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 29"; Height: 36-1/4";…
Brand: Amana Mfg #: ANZ140481

Single Packaged Heat Pump 14 SEER, Single-Phase, 4 Ton, R410A, Horizontal B74-945
Single Packaged Heat Pump 14 SEER, Single-Phase, 4 Ton, R410A, Horizontal
SEER: 14; EER: 12; Nom. Tons: 4; BtuH Cooling: 46,000; BtuH Heating Input: 44,000; Volts: 208-230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 3.8; Nom. CFM: 1,600; Min. Circuit Amps: 32.0; Refrigerant: R410A; Width: 66"; Height: 38-3/4"; Depth: 34"; Wt. Lbs.: 405;
Brand: Amana Mfg #: APH1448H41

Single Packaged Gas/Heat Air Conditioner 14 SEER, Three-Phase, 4 Ton, R410A, 81% AFUE B61-595
Single Packaged Gas/Heat Air Conditioner 14 SEER, Three-Phase, 4 Ton, R410A, 81% AFUE
SEER: 14; EER: 11; Nom. Tons: 4; BtuH Cooling: 45,500; BtuH Heating Input: 125,000; BtuH Heating Output: 100,000; Volts: 208/230; Phase: Three; Nom. CFM: 1,600; Min. Circuit Amps: 24.2; Refrigerant: R410A; Width: 46"; Height: 53"; Depth: 51-1/4"; Wt. Lbs.: 533;
Brand: Coleman Mfg #: PCG4B481253X2
FTL Finance
Powered by Site Search powered by SLI Systems
Select products to compare.
Compare