140 Results

16, 14, 5, HVAC Equipment

Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 5 Ton, R410A, Fin Tube, Southeast Region Only B77-445
Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 5 Ton, R410A, Fin Tube, Southeast Region Only
SEER: 14; EER: 11.7; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 31.7; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 38"; Height: 39-1/2"; Depth: 34-1/4"; Wt. Lbs.: 256; OEM TXV: B19-660; OEM…
Brand: Coleman Mfg #: TF4B6021S

Heat Pump 16 SEER, Single-Phase, 5 Ton, R410A B77-550
Heat Pump 16 SEER, Single-Phase, 5 Ton, R410A
SEER: 16; EER: 12.5; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.5; COP: 4.45; Min. Circuit Amps: 37.0; Max. Fuse Size: 60; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 40";…
Brand: Amana Mfg #: ASZ160601

Single Packaged Heat Pump 14 SEER, 5 Ton, Single-Phase, R410A B77-234
Single Packaged Heat Pump 14 SEER, 5 Ton, Single-Phase, R410A
SEER: 14; EER: 11; Nom. Tons: 5; BtuH Cooling: 57,500; BtuH Heating Input: 55,900; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8; COP: 4.3; Nom. CFM: 2,000; Min. Circuit Amps: 39.2; Refrigerant: R410A; Width: 45-3/4"; Height: 55"; Depth: 51-1/4"; Wt. Lbs.: 523;
Brand: Coleman Mfg #: PHE4A6021

Heat Pump 16 SEER, Two-Stage, Single-Phase, 5 Tons, R410A B91-227
Heat Pump 16 SEER, Two-Stage, Single-Phase, 5 Tons, R410A
SEER: 16; EER: 12.5; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.35; COP: 4.45; Min. Circuit Amps: 37.2; Max. Fuse Size: 60; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 35-1/2"; Height:…
Brand: Goodman Mfg #: DSZC160601

Gas/Electric Packaged Air Conditioner 16 SEER, Single-Phase, 5 Ton, 81% AFUE, R410A, Multi-Position B63-646
Gas/Electric Packaged Air Conditioner 16 SEER, Single-Phase, 5 Ton, 81% AFUE, R410A, Multi-Position
SEER: 16; EER: 12.0; Nom. Tons: 5; BtuH Cooling: 58,500; BtuH Heating Input: 138,000; BtuH Heating Output: 112,000; Volts: 208/230; Phase: 1; Motor Type: ECM; Nom. CFM: 2,000; Min. Circuit Amps: 43.4; Refrigerant: R410A; Width: 48-49/250"; Height: 42-21/25"; Depth: 73-189/200"; Wt. Lbs.: 655;
Brand: Amana Mfg #: APG1660140M41

Heat Pump GMC Series, 14 SEER, Single-Phase, 5 Ton, R410A B75-933
Heat Pump GMC Series, 14 SEER, Single-Phase, 5 Ton, R410A
SEER: 14; EER: 11.5; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.5; COP: 4.52; Min. Circuit Amps: 34.3; Max. Fuse Size: 60; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 35-1/2"; Height: 34-1/2";…
Brand: Goodman Mfg #: VSZ140601

Single Packaged Gas/Heat Air Conditioner 14 SEER, Three-Phase, 5 Ton, R410A, 81% AFUE, 460V, LOWNOx B63-664
Single Packaged Gas/Heat Air Conditioner 14 SEER, Three-Phase, 5 Ton, R410A, 81% AFUE, 460V, LOWNOx
SEER: 14; EER: 11.2; Nom. Tons: 5; BtuH Cooling: 55,000; BtuH Heating Input: 65,000; BtuH Heating Output: 53,000; Volts: 460V; Phase: Three; Nom. CFM: 2,000; Min. Circuit Amps: 11.9; Refrigerant: R410A; Width: 45-3/4; Height: 50"; Depth: 51-1/4"; Wt. Lbs.: 477;
Brand: Coleman Mfg #: PCG4B600654L1

Air Conditioning Condensing Unit Echelon™, 16 SEER, Single-Phase, 5 Ton, R410A B71-663
Air Conditioning Condensing Unit Echelon™, 16 SEER, Single-Phase, 5 Ton, R410A
SEER: 16; EER: 12.5; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 29.5; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 34"; Height: 40"; Depth: 42-1/4"; Wt. Lbs.: 235; OEM TXV: B17-087;
Brand: Coleman Mfg #: AC6B060F3C

Single Packaged Gas/Electric Air Conditioner Point Core Series, Three-Phase, 5T, R410A B64-763
Single Packaged Gas/Electric Air Conditioner Point Core Series, Three-Phase, 5T, R410A
SEER: 14.1; EER: 12.1; Nom. Tons: 5; BtuH Cooling: 58,500; BtuH Heating Input: 112,000; BtuH Heating Output: 90,000; Volts: 208/230; Phase: 3; Nom. CFM: 4,500; Refrigerant: R410A; Width: 48-9/10"; Height: 40-3/5"; Depth: 74-1/10"; Wt. Lbs.: 610;
Brand: Coleman Mfg #: ZQG06E2B1AE1A111A4

Single Packaged Heat Pump 16 SEER, Single-Phase, 5 Ton, R410A, Multi-Position B79-088
Single Packaged Heat Pump 16 SEER, Single-Phase, 5 Ton, R410A, Multi-Position
SEER: 16; EER: 12.0; Nom. Tons: 5; BtuH Cooling: 58,000; BtuH Heating Input: 55,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.2; COP: 3.8; Nom. CFM: 2,000; Min. Circuit Amps: 42.5; Refrigerant: R410A; Width: 48-49/250"; Height: 42-1/4"; Depth: 73-189/200"; Wt. Lbs.: 612;
Brand: Goodman Mfg #: GPH1660M41SUB

Heat Pump LX Series, 16 SEER, Single-Phase, 5 Ton, R410A B61-466
Heat Pump LX Series, 16 SEER, Single-Phase, 5 Ton, R410A
SEER: 16; EER: 12.5; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.0; COP: 4.18; Min. Circuit Amps: 32.4; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 38"; Height: 46"; Depth:…
Brand: Evcon Mfg #: RHP16L60B23S

Single Packaged Gas/Heat Air Conditioner LX Series, 16 SEER, Single-Phase, 5 Ton, R410A, 81% AFUE B79-054
Single Packaged Gas/Heat Air Conditioner LX Series, 16 SEER, Single-Phase, 5 Ton, R410A, 81% AFUE
SEER: 16; Nom. Tons: 5; BtuH Cooling: 58,000; BtuH Heating Input: 125,000; BtuH Heating Output: 101,000; Volts: 208/230; Phase: Single; Nom. CFM: 2,000; Min. Circuit Amps: 42.3; Refrigerant: R410A; Width: 45-3/4; Height: 55"; Depth: 51-1/4"; Wt. Lbs.: 548;
Brand: Coleman Mfg #: PCG6B601252X1

Single Packaged Air Conditioner 14 SEER, Single-Phase, 5 Ton, R410A, Horizontal B74-931
Single Packaged Air Conditioner 14 SEER, Single-Phase, 5 Ton, R410A, Horizontal
SEER: 14; EER: 12; Nom. Tons: 5; BtuH Cooling: 57500; Volts: 208/230; Phase: Single; Motor Type: ECM; Nom. CFM: 1600; Min. Circuit Amps: 40; Max. Fuse Size: 60; Refrigerant: R410A; Width: 66"; Height: 38-1/2"; Depth: 33"; Wt. Lbs.: 375;
Brand: Amana Mfg #: APC1460H41

Air Conditioning Condensing Unit GMC Series, 14 SEER, Single-Phase, 5 Ton, R410A B75-926
Air Conditioning Condensing Unit GMC Series, 14 SEER, Single-Phase, 5 Ton, R410A
SEER: 14; EER: 11.7; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 32.6; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 38-1/4"; Depth: 35-1/2"; Wt. Lbs.: 260; OEM TXV: B14-851;
Brand: Goodman Mfg #: VSX140601

Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 5 Ton, R410 , 81% AFUE B76-980
Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 5 Ton, R410 , 81% AFUE
SEER: 14; Nom. Tons: 5; BtuH Cooling: 52,500; BtuH Heating Input: 100,000; BtuH Heating Output: 80,000; Volts: 208/230V; Phase: Single; Nom. CFM: 2,000; Min. Circuit Amps: 42.6; Refrigerant: R410A; Width: 45-3/4"; Height: 51"; Depth: 51"; Wt. Lbs.: 60;
Brand: Coleman Mfg #: PCG4B601002X2

Heat Pump 14 SEER, Single-Phase, 5 Ton, R410A B76-779
Heat Pump 14 SEER, Single-Phase, 5 Ton, R410A
SEER: 14; EER: 11.5; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.5; COP: 4.52; Min. Circuit Amps: 34.3; Max. Fuse Size: 60; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 34-1/2";…
Brand: Amana Mfg #: ANZ140601

Heat Pump 14.5 SEER, Single-Phase, 5 Ton, R410A B76-048
Heat Pump 14.5 SEER, Single-Phase, 5 Ton, R410A
SEER: 14.5; EER: 12.2; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: Condenser Fan; HSPF: 9.0; COP: 3.7; Min. Circuit Amps: 37.3; Max. Fuse Size: 60; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 34"; Height:…
Brand: Evcon Mfg #: RHP14J604S22

Single Packaged Gas/Heat Air Conditioner 16 SEER, Three-Phase, 5 Ton, R410A, 81% AFUE B60-730
Single Packaged Gas/Heat Air Conditioner 16 SEER, Three-Phase, 5 Ton, R410A, 81% AFUE
SEER: 16.0; EER: 12.0; Nom. Tons: 5; BtuH Cooling: 58,000; BtuH Heating Input: 65,000; BtuH Heating Output: 52,000; Volts: 208/230; Phase: Three; Motor Type: ECM; Nom. CFM: 2,000; Min. Circuit Amps: 13.7; Refrigerant: R410A; Width: 45-3/4"; Height: 55"; Depth: 51-1/4"; Wt. Lbs.: 532;
Brand: Coleman Mfg #: PCG6B600653X1

Single Packaged Gas/Heat Air Conditioner 16 SEER, Three-Phase, 5 Ton, R410A, 81% AFUE B60-732
Single Packaged Gas/Heat Air Conditioner 16 SEER, Three-Phase, 5 Ton, R410A, 81% AFUE
SEER: 16.0; EER: 12.0; Nom. Tons: 5; BtuH Cooling: 58,000; BtuH Heating Input: 125,000; BtuH Heating Output: 101,000; Volts: 208/230; Phase: Three; Motor Type: ECM; Nom. CFM: 2,000; Min. Circuit Amps: 13.7; Refrigerant: R410A; Width: 45-3/4"; Height: 55"; Depth: 51-1/4"; Wt. Lbs.: 543;
Brand: Coleman Mfg #: PCG6B601253X1

Manufactured Housing Air Conditioning Condensing Unit 14 SEER Sweat Fit 5 Ton, R410A B60-932
Manufactured Housing Air Conditioning Condensing Unit 14 SEER Sweat Fit 5 Ton, R410A
Nom. Tons: 5; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Width: 35-1/2"; Height: 47"; Depth: 35-1/2"; Wt. Lbs.: 230; SEER: 14;
Brand: Maytag Mfg #: RSCS604

Packaged Heat Pump 16 SEER, Single-Phase, Single-Stage, 5 Ton, R410A B60-889
Packaged Heat Pump 16 SEER, Single-Phase, Single-Stage, 5 Ton, R410A
SEER: 16; EER: 12.5; Nom. Tons: 5; BtuH Cooling: 57,500; BtuH Heating Input: 125,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.2; COP: 3.6; Nom. CFM: 1,800; Min. Circuit Amps: 44.7; Refrigerant: R410A; Width: 45-3/4"; Height: 55"; Depth: 51-1/4"; Wt. Lbs.: 588;
Brand: Coleman Mfg #: PHG6B601252X1

Dual Fuel Packaged Heat Pump 16 SEER, Single-Phase, Single-Stage, 5 Ton, R410A B60-888
Dual Fuel Packaged Heat Pump 16 SEER, Single-Phase, Single-Stage, 5 Ton, R410A
SEER: 16; EER: 12.5; Nom. Tons: 5; BtuH Cooling: 57,500; BtuH Heating Input: 100,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.2; COP: 3.6; Nom. CFM: 1,800; Min. Circuit Amps: 44.7; Refrigerant: R410A; Width: 45-3/4"; Height: 55"; Depth: 51-1/4"; Wt. Lbs.: 581;
Brand: Coleman Mfg #: PHG6B601002X1

Gas/Electric Packaged Air Conditioner 14 SEER, Single-Phase, 5 Ton, 81% AFUE, R410A, Ultra LowNOx B64-925
Gas/Electric Packaged Air Conditioner 14 SEER, Single-Phase, 5 Ton, 81% AFUE, R410A, Ultra LowNOx
SEER: 16; EER: 11; Nom. Tons: 5; BtuH Cooling: 56,000; BtuH Heating Input: 80,000; BtuH Heating Output: 64,000; Volts: 208/230; Phase: Single; Nom. CFM: 1,700; Min. Circuit Amps: 37.6; Refrigerant: R410A; Width: 47"; Height: 40"; Depth: 51"; Wt. Lbs.: 533;
Brand: Goodman Mfg #: GPU1636080M41

Single Packaged Heat Pump 16 SEER, Single-Phase, 5 Ton, R410A, Multi-Position B63-647
Single Packaged Heat Pump 16 SEER, Single-Phase, 5 Ton, R410A, Multi-Position
SEER: 16; EER: 12.0; Nom. Tons: 5; BtuH Cooling: 58,000; BtuH Heating Input: 58,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.2; COP: 3.7; Nom. CFM: 1800; Min. Circuit Amps: 44.0; Refrigerant: R410A; Width: 48-49/250"; Height: 42-21/25"; Depth: 73-189/200"; Wt. Lbs.: 688;
Brand: Amana Mfg #: APH1660M41
FTL Finance
Powered by Site Search powered by SLI Systems
Select products to compare.