404 Results

460, 120, HVAC Equipment

Single Packaged Gas/Heat Air Conditioner 14 SEER, Three-Phase, 5 Ton, R410, 81% AFUE B78-654
Single Packaged Gas/Heat Air Conditioner 14 SEER, Three-Phase, 5 Ton, R410, 81% AFUE
SEER: 14; EER: 11; Nom. Tons: 5; BtuH Cooling: 52,500; BtuH Heating Input: 125,000; BtuH Heating Output: 100,000; Volts: 460; Phase: Three; Nom. CFM: 2,000; Min. Circuit Amps: 13.8; Refrigerant: R410A; Width: 45-3/4"; Height: 55"; Depth: 51-1/4"; Wt. Lbs.: 543;
Brand: Coleman Mfg #: PCG4B601254X1

Single Packaged Heat Pump 14 SEER/12 EER, Three-Phase, 4 Ton, R410A Belt Drive B79-495
Single Packaged Heat Pump 14 SEER/12 EER, Three-Phase, 4 Ton, R410A Belt Drive
Nom. Tons: 4; BtuH Cooling: 46,500; BtuH Heating Input: 45,500; EER: 12.0; HSPF: 8.0; COP: 3.6; Motor Type: Belt; Volts: 460V; Nom. CFM: 1,600; Min. Circuit Amps: 10; Width: 73-189/200"; Height: 38-21/25"; Depth: 48-49/250"; Wt. Lbs.: 585;
Brand: Daikin Mfg #: DSH048XXX4BXXX

Single Packaged Heat Pump 14 SEER/12 EER, Three-Phase, 3 Ton, R410A Belt Drive B79-493
Single Packaged Heat Pump 14 SEER/12 EER, Three-Phase, 3 Ton, R410A Belt Drive
Nom. Tons: 3; BtuH Cooling: 36,000; BtuH Heating Input: 36,000; EER: 12.0; HSPF: 8.0; COP: 3.6; Motor Type: Belt; Volts: 460V; Nom. CFM: 1,200; Min. Circuit Amps: 9.6; Width: 73-189/200"; Height: 38-21/25"; Depth: 48-49/250"; Wt. Lbs.: 580;
Brand: Daikin Mfg #: DSH036XXX4BXXX

Modular Air Handler MP Series, PSC L93-541
Modular Air Handler MP Series, PSC
Volts: 460; Nom. CFM: 1,400; Max. Fuse Size: 15; Width: 24-1/2"; Height: 22-1/2"; Depth: 21-1/2"; Wt. Lbs.: 74; Motor Type: PSC; Air Handler Type: Modular; Configuration: Multi-Position;
Brand: Coleman Mfg #: MP14DN41

Vertical Air Handler L94-139
Vertical Air Handler
Nom. Tons: 3; Volts: 120; Nom. CFM: 1,200; CFM @ 0.5" ESP: 1,200; CFM High @ 0.3 ESP: 1,040; Min. Circuit Amps: 3.8; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 5/8"; Width: 22-1/8"; Height: 43"; Depth: 18-1/8"; Wt. Lbs.: 130; Motor Type: PSC; Air Handler Type: Vertical Front Return;…
Brand: First Co Mfg #: 12CW

Mid-Size Fan Forced Wall Heater with Back Can X92-385
Mid-Size Fan Forced Wall Heater with Back Can
Watts: 750; Volts: 120; BtuH: 2,560; Amps: 6.25; Wt. Lbs.: 6;
Brand: TPI Mfg #: E3275TRPW

Heat Kit Three-Phase L80-215
Heat Kit Three-Phase
Nom. kW: 15.0; Volts: 460;
Brand: Goodman Mfg #: EHK4-15

Single Packaged Air Conditioner 14 SEER, Three-Phase, 5 Ton, R410A B78-660
Single Packaged Air Conditioner 14 SEER, Three-Phase, 5 Ton, R410A
SEER: 14; EER: 11.0; Nom. Tons: 5; BtuH Cooling: 52,500; Volts: 460; Phase: Three; Motor Type: ECM; Nom. CFM: 2,000; Min. Circuit Amps: 27.6; Max. Fuse Size: 35; Refrigerant: R410A; Width: 45-3/4"; Height: 55"; Depth: 51-1/4"; Wt. Lbs.: 500;
Brand: Coleman Mfg #: PCE4B6041

Single Packaged Heat Pump 14 SEER, 5 Ton, Three-Phase, R410A B78-657
Single Packaged Heat Pump 14 SEER, 5 Ton, Three-Phase, R410A
Nom. Tons: 5; BtuH Cooling: 58,000; BtuH Heating Input: 56,000; EER: 11.0; HSPF: 8.0; COP: 3.6; Motor Type: ECM; Volts: 460; Nom. CFM: 1,800; Min. Circuit Amps: 13.8; Width: 45-3/4"; Height: 55"; Depth: 51-1/4"; Wt. Lbs.: 523;
Brand: Coleman Mfg #: PHE4B6041

Raywall Register Style Fan-Forced Wall Heater X91-002
Raywall Register Style Fan-Forced Wall Heater
Watts: 750; Volts: 120; BtuH: 2,560; Amps: 6.25; Wt. Lbs.: 8;
Brand: TPI Mfg #: E4875RPW

Raywall Register Style Fan-Forced Wall Heater X91-004
Raywall Register Style Fan-Forced Wall Heater
Watts: 1,500; Volts: 120; BtuH: 5,120; Amps: 12.50; Wt. Lbs.: 8;
Brand: TPI Mfg #: E4815RPW

Heat Kit Three-Phase L80-272
Heat Kit Three-Phase
Nom. kW: 16.0; Volts: 460;
Brand: Goodman Mfg #: EHK4-16

Heat Kit Three-Phase L80-211
Heat Kit Three-Phase
Nom. kW: 10.0; Volts: 460;
Brand: Goodman Mfg #: EHK4-10

Infrared Electric Heater Indoor/Outdoor Applications X93-113
Infrared Electric Heater Indoor/Outdoor Applications
kW: 1.0; BtuH: 3,412; Volts: 120; Phase: 1; Amps: 8.3; Watts: 1,000; Shipping Dimensions: 9" W x 9" H x 36" L; Shipping Wt. Lbs.: 12; Reflector Pattern: 60º Symmetrical; Length: 33";
Brand: Infrasave Mfg #: ES-1033-12

Infrared Electric Heater Indoor/Outdoor Applications X93-114
Infrared Electric Heater Indoor/Outdoor Applications
kW: 1.5; BtuH: 5,118; Volts: 120; Phase: 1; Amps: 12.5; Watts: 1,500; Shipping Dimensions: 9" W x 9" H x 36" L; Shipping Wt. Lbs.: 12; Reflector Pattern: 60º Symmetrical; Length: 33";
Brand: Infrasave Mfg #: ES-1533-12

Infrared Electric Heater Indoor/Outdoor Applications X93-111
Infrared Electric Heater Indoor/Outdoor Applications
kW: 0.5; BtuH: 1,706; Volts: 120; Phase: 1; Amps: 4.2; Watts: 500; Shipping Dimensions: 9" W x 9" H x 22" L; Shipping Wt. Lbs.: 10; Reflector Pattern: 60º Symmetrical; Length: 19-1/2";
Brand: Infrasave Mfg #: ES-0519-12

Infrared Electric Heater Indoor/Outdoor Applications X93-112
Infrared Electric Heater Indoor/Outdoor Applications
kW: 0.75; BtuH: 2,559; Volts: 120; Phase: 1; Amps: 6.3; Watts: 750; Shipping Dimensions: 9" W x 9" H x 22" L; Shipping Wt. Lbs.: 10; Reflector Pattern: 60º Symmetrical; Length: 19-1/2";
Brand: Infrasave Mfg #: ES-0719-12

Raywall Register Style Fan-Forced Wall Heater X91-003
Raywall Register Style Fan-Forced Wall Heater
Watts: 1,000; Volts: 120; BtuH: 3,413; Amps: 8.33; Wt. Lbs.: 8;
Brand: TPI Mfg #: E4810RPW

Trimline Replacement Quartz Tube X90-972
Trimline Replacement Quartz Tube
Volts: 120; Watts: 1,500; Overall Length: 39-11/16"; Heated Length: 34-3/16";
Brand: TPI Mfg #: 671-3784

Quartz Infrared Electric Spot Heater Trimline Series X90-962
Quartz Infrared Electric Spot Heater Trimline Series
kW: 1.5; BtuH: 5,120; Volts: 120; Amps: 12.5; Watts: 120; Shipping Dimensions: 7" W x 46" L x 7" H; Shipping Wt. Lbs.: 15; Reflector Pattern: 60º Symmetrical;
Brand: TPI Mfg #: OCH-46-120-VCE
FTL Finance
Powered by Site Search powered by SLI Systems
Select products to compare.
Compare