219 Results

Bell & Gossett, Kaowool, Oil Heat Controls, Controls, HVACR Parts, Hydronics & Plumbing

Air Vent L39-689
Air Vent
Model #: 107A; Type: High Capacity; Conn. Size: 3/4" NPTF; Height: 9-5/8"; Width: 4-1/2";
Brand: Bell & Gossett Mfg #: 113076

Air Vent L39-686
Air Vent
Model #: 4V; Type: Manual; Conn. Size: 1/8" NPTM; Height: 5/8"; Width: 5/8";
Brand: Bell & Gossett Mfg #: 113055

Air Vent L39-687
Air Vent
Model #: 97; Type: Automatic; Conn. Size: 1/8" NPTM; Height: 3-1/8"; Width: 1-7/8";
Brand: Bell & Gossett Mfg #: 113222

Air Vent L39-688
Air Vent
Model #: 87; Type: Automatic; Conn. Size: 3/4" NPTM, 1/2" NPTF; Height: 4-3/4"; Width: 2-1/4";
Brand: Bell & Gossett Mfg #: 113021

Autocirc® Domestic Hot Water Recirculator Pump L81-494
Autocirc® Domestic Hot Water Recirculator Pump
Model #: ecocirc® wireless Recirculation Kit; Description: ecocirc® wireless Recirculation Kit; Body Type: Brass; Volts: 115; Phase: 1; Wt. Lbs.: 4.0;
Brand: Bell & Gossett Mfg #: 6050B4000

Autocirc® Domestic Hot Water Recirculator Pump L81-493
Autocirc® Domestic Hot Water Recirculator Pump
Model #: ecocirc B 23-5 ACT; Description: Undersink Pump for Potable Water Systems; Body Type: Brass; Volts: 115; Phase: 1; Wt. Lbs.: 7.0;
Brand: Bell & Gossett Mfg #: 6050B7016

Bearing Assembly Series 1510 L80-961
Bearing Assembly Series 1510
Description: Bearing Assembly; Application: Series 1510;
Brand: Bell & Gossett Mfg #: 185011LF

Booster Pump L86-074
Booster Pump
Body Type: Iron; Volts: 115; Phase: 1; RPM: 1725; HP: 1/12; Conn.: NPTF; Flange Size: 3/4" 1", 1-1/4", 1-1/2"; Wt. Lbs.: 19; GPM @ 0': 38; GPM @ 4': 25; GPM @ 8': 5;
Brand: Bell & Gossett Mfg #: 106189

Booster Pump For Hydronic Heating and Cooling Systems and Service Water Heating L80-532
Booster Pump For Hydronic Heating and Cooling Systems and Service Water Heating
Body Type: Bronze; Volts: 115; Phase: 1; RPM: 1725; HP: 1/12; Conn.: NPTF; Flange Size: 3/4", 1", 1-1/4", 1-1/2"; Wt. Lbs.: 21; GPM @ 0': 38; GPM @ 4': 25; GPM @ 8': 5;
Brand: Bell & Gossett Mfg #: 106192LF

Booster Pump For Hydronic Heating and Cooling Systems and Service Water Heating L80-528
Booster Pump For Hydronic Heating and Cooling Systems and Service Water Heating
Body Type: Bronze; Volts: 115; Phase: 1; RPM: 1725; HP: 1/6; Conn.: NPTF; Flange Size: 1", 1-1/4", 1-1/2"; Wt. Lbs.: 30; GPM @ 0': 40; GPM @ 4': 35; GPM @ 8': 28;
Brand: Bell & Gossett Mfg #: 102213LF

Booster Pumps For Hydronic Heating and Cooling Systems and Service Water Heating L86-076
Booster Pumps For Hydronic Heating and Cooling Systems and Service Water Heating
Body Type: Iron; Volts: 115; Phase: 1; RPM: 1725; HP: 1/6; Conn.: NPTF; Flange Size: 1", 1-1/4", 1-1/2"; Wt. Lbs.: 28; GPM @ 0': 40; GPM @ 4': 35; GPM @ 8': 28;
Brand: Bell & Gossett Mfg #: 102210

Booster Pumps For Hydronic Heating and Cooling Systems and Service Water Heating L86-102
Booster Pumps For Hydronic Heating and Cooling Systems and Service Water Heating
Body Type: Iron; Volts: 115; Phase: 1; RPM: 1725; HP: 1/6; Conn.: NPTF; Flange Size: 2"; Wt. Lbs.: 40; GPM @ 0': 75; GPM @ 4': 60; GPM @ 8': 42;
Brand: Bell & Gossett Mfg #: 102214

Booster Pumps For Hydronic Heating and Cooling Systems and Service Water Heating L86-103
Booster Pumps For Hydronic Heating and Cooling Systems and Service Water Heating
Body Type: Iron; Volts: 115; Phase: 1; RPM: 1725; HP: 1/3; Conn.: NPTF; Flange Size: 3"; Wt. Lbs.: 55; GPM @ 0': 115; GPM @ 4': 112; GPM @ 8': 95; GPM @ 12': 74; GPM @ 16': 43;
Brand: Bell & Gossett Mfg #: 102226

Check-Trol Isolation Flow Control Flange L45-884
Check-Trol Isolation Flow Control Flange
Conn. Size: 1" NPT x Flange;
Brand: Bell & Gossett Mfg #: 101232LF

Check-Trol Isolation Flow Control Flange L45-883
Check-Trol Isolation Flow Control Flange
Conn. Size: 3/4" NPT x Flange;
Brand: Bell & Gossett Mfg #: 101231LF

Check-Trol Isolation Flow Control Flange L45-885
Check-Trol Isolation Flow Control Flange
Conn. Size: 1-1/4" NPT x Flange;
Brand: Bell & Gossett Mfg #: 101233LF

Check-Trol Isolation Flow Control Flange L45-887
Check-Trol Isolation Flow Control Flange
Conn. Size: 1" Sweat x Flange;
Brand: Bell & Gossett Mfg #: 101237LF

Check-Trol Isolation Flow Control Flange L45-886
Check-Trol Isolation Flow Control Flange
Conn. Size: 3/4" Sweat x Flange;
Brand: Bell & Gossett Mfg #: 101236LF

Check-Trol Isolation Flow Control Flange L45-888
Check-Trol Isolation Flow Control Flange
Conn. Size: 1-1/4" Sweat x Flange;
Brand: Bell & Gossett Mfg #: 101238LF

Check-Trol Isolation Flow Control Flange L45-892
Check-Trol Isolation Flow Control Flange
Conn. Size: 1-1/2" Sweat x Flange;
Brand: Bell & Gossett Mfg #: 101247LF

Check-Trol Isolation Flow Control Flange L45-891
Check-Trol Isolation Flow Control Flange
Conn. Size: 1-1/2" NPT x Flange;
Brand: Bell & Gossett Mfg #: 101245LF

Circuit Setter Calibrated Balance Valve L46-202
Circuit Setter Calibrated Balance Valve
Conn. Size: 3/4" NPT; Cv: 3.1;
Brand: Bell & Gossett Mfg #: 117415LF

Circuit Setter Calibrated Balance Valve L46-200
Circuit Setter Calibrated Balance Valve
Conn. Size: 3/4" Sweat; Cv: 2.5;
Brand: Bell & Gossett Mfg #: 117413LF

Circuit Setter Calibrated Balance Valve L46-199
Circuit Setter Calibrated Balance Valve
Conn. Size: 1/2" Sweat; Cv: 2.2;
Brand: Bell & Gossett Mfg #: 117412LF