74 Results

Bell & Gossett, Hydronic, Pumps, Pumps & Parts, Hydronics & Plumbing

Booster Pump L86-074
Booster Pump
Body Type: Iron; Volts: 115; Phase: 1; RPM: 1725; HP: 1/12; Conn.: NPTF; Flange Size: 3/4" 1", 1-1/4", 1-1/2"; Wt. Lbs.: 19; GPM @ 0': 38; GPM @ 4': 25; GPM @ 8': 5;
Brand: Bell & Gossett Mfg #: 106189

Booster Pumps For Hydronic Heating and Cooling Systems and Service Water Heating L86-076
Booster Pumps For Hydronic Heating and Cooling Systems and Service Water Heating
Body Type: Iron; Volts: 115; Phase: 1; RPM: 1725; HP: 1/6; Conn.: NPTF; Flange Size: 1", 1-1/4", 1-1/2"; Wt. Lbs.: 28; GPM @ 0': 40; GPM @ 4': 35; GPM @ 8': 28;
Brand: Bell & Gossett Mfg #: 102210

Permanently Lubricated Circulator Pump L39-664
Permanently Lubricated Circulator Pump
Model #: PL-36; Body Type: Cast Iron; Volts: 115; Phase: 1; RPM: 3300; HP: 1/6; Conn.: NPTF; Flange Size: 3/4", 1", 1-1/4", 1-1/2"; Wt. Lbs.: 13.1; GPM @ 0': 40; GPM @ 5': 36; GPM @ 10': 33; GPM @ 15': 27; GPM @ 20': 23; GPM @ 25': 16; GPM @ 30': 10; GPM @ 35': 4;
Brand: Bell & Gossett Mfg #: 1BL001

Booster Pump For Hydronic Heating and Cooling Systems and Service Water Heating L80-532
Booster Pump For Hydronic Heating and Cooling Systems and Service Water Heating
Body Type: Bronze; Volts: 115; Phase: 1; RPM: 1725; HP: 1/12; Conn.: NPTF; Flange Size: 3/4", 1", 1-1/4", 1-1/2"; Wt. Lbs.: 21; GPM @ 0': 38; GPM @ 4': 25; GPM @ 8': 5;
Brand: Bell & Gossett Mfg #: 106192LF

Permanently Lubricated Circulator Pump L80-536
Permanently Lubricated Circulator Pump
Model #: PL-30B; Body Type: Bronze; Volts: 115; Phase: 1; RPM: 2650; HP: 1/12; Conn.: NPTF; Flange Size: 3/4", 1", 1-1/4", 1-1/2"; Wt. Lbs.: 11.6; GPM @ 0': 30; GPM @ 5': 25; GPM @ 10': 20; GPM @ 15': 14; GPM @ 20': 6;
Brand: Bell & Gossett Mfg #: 1BL013LF

Permanently Lubricated Circulator Pump L80-534
Permanently Lubricated Circulator Pump
Model #: PL-36B; Body Type: Bronze; Volts: 115; Phase: 1; RPM: 3300; HP: 1/6; Conn.: NPTF; Flange Size: 3/4", 1", 1-1/4", 1-1/2"; Wt. Lbs.: 13.1; GPM @ 0': 40; GPM @ 5': 36; GPM @ 10': 33; GPM @ 15': 27; GPM @ 20': 23; GPM @ 25': 16; GPM @ 30': 10; GPM @ 35': 4;
Brand: Bell & Gossett Mfg #: 1BL003LF

Booster Pumps For Hydronic Heating and Cooling Systems and Service Water Heating L86-102
Booster Pumps For Hydronic Heating and Cooling Systems and Service Water Heating
Body Type: Iron; Volts: 115; Phase: 1; RPM: 1725; HP: 1/6; Conn.: NPTF; Flange Size: 2"; Wt. Lbs.: 40; GPM @ 0': 75; GPM @ 4': 60; GPM @ 8': 42;
Brand: Bell & Gossett Mfg #: 102214

Wet Rotor Circulator L87-196
Wet Rotor Circulator
Model #: NRF-36; Body Type: Iron; Volts: 115; Phase: 1; RPM: 3300; HP: 1/6; Conn.: NPTF; Flange Size: 3/4" 1", 1-1/4", 1-1/2"; Wt. Lbs.: 13.1; GPM @ 0': 38; GPM @ 4': 35; GPM @ 8': 31; GPM @ 12': 28; GPM @ 16': 23; GPM @ 20': 18; GPM @ 25': 13;
Brand: Bell & Gossett Mfg #: 103400

System Lubricated Circulator Pump For Hydronic and Solar Applications L80-529
System Lubricated Circulator Pump For Hydronic and Solar Applications
Model #: NBF-22; Body Type: Bronze; Volts: 115; Phase: 1; RPM: 2940; HP: 1/25; Conn.: NPTF; Flange Size: 3/4", 1", 1-1/4", 1-1/2"; Wt. Lbs.: 9.5; GPM @ 0': 22; GPM @ 4': 16; GPM @ 8': 9.5; GPM @ 12': 4.5;
Brand: Bell & Gossett Mfg #: 103252LF

Circulator Pump L86-179
Circulator Pump
Model #: NRF-22; Body Type: Iron; Volts: 115; Phase: 1; RPM: 2940; HP: 1/25; Conn.: NPTF; Flange Size: 3/4" 1", 1-1/4", 1-1/2"; Wt. Lbs.: 9.3; GPM @ 0': 22; GPM @ 4': 16; GPM @ 8': 9.5; GPM @ 12': 4.5;
Brand: Bell & Gossett Mfg #: 103251

Permanently Lubricated Circulator Pump L39-666
Permanently Lubricated Circulator Pump
Model #: PL-45; Body Type: Cast Iron; Volts: 115; Phase: 1; RPM: 3300; HP: 1/6; Conn.: NPTF; Flange Size: 1", 1-1/4", 1-1/2"; Wt. Lbs.: 14.5; GPM @ 0': 47; GPM @ 5': 44; GPM @ 10': 37; GPM @ 15': 31; GPM @ 20': 23; GPM @ 25': 13;
Brand: Bell & Gossett Mfg #: 1BL002

Permanently Lubricated Circulator Pump L80-535
Permanently Lubricated Circulator Pump
Model #: PL-45B; Body Type: Bronze; Volts: 115; Phase: 1; RPM: 3300; HP: 1/6; Conn.: NPTF; Flange Size: 1", 1-1/4", 1-1/2"; Wt. Lbs.: 14.5; GPM @ 0': 47; GPM @ 5': 44; GPM @ 10': 37; GPM @ 15': 31; GPM @ 20': 23; GPM @ 25': 13;
Brand: Bell & Gossett Mfg #: 1BL004LF

Permanently Lubricated Circulator Pump L39-662
Permanently Lubricated Circulator Pump
Model #: PL-30; Body Type: Cast Iron; Volts: 115; Phase: 1; RPM: 2650; HP: 1/12; Conn.: NPTF; Flange Size: 3/4", 1", 1-1/4", 1-1/2"; Wt. Lbs.: 11.6; GPM @ 0': 30; GPM @ 5': 25; GPM @ 10': 20; GPM @ 15': 14; GPM @ 20': 6;
Brand: Bell & Gossett Mfg #: 1BL012

Booster Pump For Hydronic Heating and Cooling Systems and Service Water Heating L80-528
Booster Pump For Hydronic Heating and Cooling Systems and Service Water Heating
Body Type: Bronze; Volts: 115; Phase: 1; RPM: 1725; HP: 1/6; Conn.: NPTF; Flange Size: 1", 1-1/4", 1-1/2"; Wt. Lbs.: 30; GPM @ 0': 40; GPM @ 4': 35; GPM @ 8': 28;
Brand: Bell & Gossett Mfg #: 102213LF

Compact System Lubricated Circulator Pump L80-533
Compact System Lubricated Circulator Pump
Model #: LR-15WR; Body Type: Bronze; Volts: 115; Phase: 1; RPM: 2950; HP: 1/15; Conn.: NPTF; Flange Size: 3/4", 1", 1-1/4", 1-1/2"; Wt. Lbs.: 10; GPM @ 0': 37; GPM @ 4': 25; GPM @ 8': 9;
Brand: Bell & Gossett Mfg #: 106514LF

ecocirc+ 20-18 Variable Speed ECM Smart Circulator L82-614
ecocirc+ 20-18 Variable Speed ECM Smart Circulator
Model #: ecocirc 20-18 Prem S.S. U; Body Type: Stainless Steel; Volts: 115; RPM: Variable; Conn.: 1-1/4" NPSM Union Thread; Flange to Flange: 6"; Wt. Lbs.: 4.61; Shutoff: 20; GPM @ 0': 18; GPM @ 1': 18; GPM @ 2': 18; GPM @ 3': 17.5; GPM @ 4': 17.2; GPM @ 5': 17; GPM @ 6': 16.5; GPM @ 7': 16; GPM @…
Brand: Bell & Gossett Mfg #: 60B0B1005

ecocirc+ 20-18 Variable Speed ECM Smart Circulator L82-612
ecocirc+ 20-18 Variable Speed ECM Smart Circulator
Model #: ecocirc 20-18 Prem CI F; Body Type: Cast Iron; Volts: 115; RPM: Variable; Conn.: 2-Bolt Small Booster Flange; Flange to Flange: 6-3/8"; Wt. Lbs.: 6.2; Shutoff: 20; GPM @ 0': 18; GPM @ 1': 18; GPM @ 2': 18; GPM @ 3': 17.5; GPM @ 4': 17.2; GPM @ 5': 17; GPM @ 6': 16.5; GPM @ 7': 16; GPM @…
Brand: Bell & Gossett Mfg #: 60B0B1003

ecocirc+ 20-18 Variable Speed ECM Smart Circulator L82-613
ecocirc+ 20-18 Variable Speed ECM Smart Circulator
Model #: ecocirc 20-18 Prem S.S. F; Body Type: Stainless Steel; Volts: 115; RPM: Variable; Conn.: 2-Bolt Small Booster Flange; Flange to Flange: 6-3/8"; Wt. Lbs.: 5.86; Shutoff: 20; GPM @ 0': 18; GPM @ 1': 18; GPM @ 2': 18; GPM @ 3': 17.5; GPM @ 4': 17.2; GPM @ 5': 17; GPM @ 6': 16.5; GPM @ 7':…
Brand: Bell & Gossett Mfg #: 60B0B1004

Booster Pumps For Hydronic Heating and Cooling Systems and Service Water Heating L86-103
Booster Pumps For Hydronic Heating and Cooling Systems and Service Water Heating
Body Type: Iron; Volts: 115; Phase: 1; RPM: 1725; HP: 1/3; Conn.: NPTF; Flange Size: 3"; Wt. Lbs.: 55; GPM @ 0': 115; GPM @ 4': 112; GPM @ 8': 95; GPM @ 12': 74; GPM @ 16': 43;
Brand: Bell & Gossett Mfg #: 102226

Commercial 60 Series Pump L80-959
Commercial 60 Series Pump
Model #: 608S; Body Type: Iron; Volts: 115/230; Phase: 1; RPM: 1750; HP: 1/2; Conn.: NPTF; Flange Size: 1-1/2"; Wt. Lbs.: 61; GPM @ 12': 79; GPM @ 16': 65; GPM @ 18': 55; GPM @ 20': 45; GPM @ 28': 5;
Brand: Bell & Gossett Mfg #: 1EF022LF

Commercial 60 Series Pump L80-960
Commercial 60 Series Pump
Model #: 611S; Body Type: Iron; Volts: 115/230; Phase: 1; RPM: 1750; HP: 3/4; Conn.: NPTF; Flange Size: 2"; Wt. Lbs.: 71; GPM @ 12': 140; GPM @ 16': 118; GPM @ 18': 100; GPM @ 20': 80; GPM @ 28': 40;
Brand: Bell & Gossett Mfg #: 1EF027LF

Header Mounted Pump Laars/Raypak Boilers L87-197
Header Mounted Pump Laars/Raypak Boilers
Model #: NRF-45; Body Type: Iron; Volts: 115; Phase: 1; RPM: 3300; HP: 1/6; Conn.: NPTF; Flange Size: 1", 1-1/4", 1-1/2"; Wt. Lbs.: 14.5; GPM @ 0': 45; GPM @ 4': 39; GPM @ 8': 32; GPM @ 12': 28; GPM @ 16': 20; GPM @ 20': 13; GPM @ 25': 4;
Brand: Bell & Gossett Mfg #: 103404

Autocirc® Domestic Hot Water Recirculator Pump L81-494
Autocirc® Domestic Hot Water Recirculator Pump
Model #: ecocirc® wireless Recirculation Kit; Description: ecocirc® wireless Recirculation Kit; Body Type: Brass; Volts: 115; Phase: 1; Wt. Lbs.: 4.0;
Brand: Bell & Gossett Mfg #: 6050B4000

System Lubricated Circulator Pump For Hydronic and Solar Applications L81-156
System Lubricated Circulator Pump For Hydronic and Solar Applications
Model #: NBF-25; Body Type: Bronze; Volts: 115; Phase: 1; RPM: 2950; HP: 1/6; Conn.: NPTF; Flange Size: 3/4", 1", 1-1/4", 1-1/2"; Wt. Lbs.: 0; GPM @ 0': 24; GPM @ 4': 20; GPM @ 8': 14; GPM @ 12': 10; GPM @ 16': 4;
Brand: Bell & Gossett Mfg #: 103418LF
FTL Finance
Powered by Site Search powered by SLI Systems
Select products to compare.
Compare