384 Results

Through the Wall Condensing Units & Heat Pumps, Specialty, HVAC Equipment, Blowers & Draft Inducers, Motors

Thru-the-Wall Condensing Unit 1000 Series, Single-Phase, 2 Ton, R410A B66-540
Thru-the-Wall Condensing Unit 1000 Series, Single-Phase, 2 Ton, R410A
Volts: 208-230/1; BtuH Cooling: 22600; Width: 26-1/4"; Height: 28-5/8"; Depth: 18-1/2"; Wt. Lbs.: 180;
Brand: National Comfort Products Mfg #: NCP4241000A

Replacement for Trane Draft Inducer Blower X89-695
Replacement for Trane Draft Inducer Blower
HP: 1/29; Volts: 208–230; RPM: 3000; F/L Amps: 0.50; Rot.: CCWSE; Bearing Type: Slv; Safety Switch: No; Replaces: 7021-7833, 7021-8928; Wt. Lbs.: 3.60;
Brand: Fasco Mfg #: A150

Thru-the-Wall Condensing Unit 3000 Series, Single-Phase, 1.5 Ton, R410A B66-537
Thru-the-Wall Condensing Unit 3000 Series, Single-Phase, 1.5 Ton, R410A
Volts: 208-230/1; BtuH Cooling: 18000; Width: 24-1/8"; Height: 32"; Depth: 18-1/2"; Wt. Lbs.: 180;
Brand: National Comfort Products Mfg #: NCP4183000A

Thru-the-Wall Package Unit Comfort Pack Series, Gas Heat, 80% AFUE, R410A B66-499
Thru-the-Wall Package Unit Comfort Pack Series, Gas Heat, 80% AFUE, R410A
Volts: 208-230/1; BtuH Cooling: 21600; BtuH Heating: 40800; Fan Speeds: 5; Width: 28"; Height: 43"; Depth: 31-15/32"; Wt. Lbs.: 310;
Brand: National Comfort Products Mfg #: CP842451UA

Replacement for Rheem Draft Inducer Blower X82-556
Replacement for Rheem Draft Inducer Blower
HP: 1/50; Volts: 115; RPM: 3000; F/L Amps: 0.6; Rot.: CCWLE; Bearing Type: Ball; Safety Switch: No; Replaces: 70-101087-81, 7021-11559; Wt. Lbs.: 6.7;
Brand: Packard Mfg #: 66781

Thru-the-Wall Condensing Unit 1000 Series, Single-Phase, 1.5 Ton, R410A B66-536
Thru-the-Wall Condensing Unit 1000 Series, Single-Phase, 1.5 Ton, R410A
Volts: 208-230/1; BtuH Cooling: 18000; Width: 26-1/4"; Height: 28-5/8"; Depth: 18-1/2"; Wt. Lbs.: 180;
Brand: National Comfort Products Mfg #: NCP4181000A

Replacement for Trane Draft Inducer Blowers X82-106
Replacement for Trane Draft Inducer Blowers
HP: 1/25; Volts: 115; RPM: 3200; F/L Amps: 1.35; Rot.: CW; Bearing Type: Slv; Safety Switch: No; Replaces: 7021-11544S, 7021-11544, 7021-9065; Wt. Lbs.: 5.60;
Brand: Fasco Mfg #: A196

Air Conditioning Condensing Unit Thru-The-Wall 13 SEER, Single-Phase, 2 TON, R410A B61-349
Air Conditioning Condensing Unit Thru-The-Wall 13 SEER, Single-Phase, 2 TON, R410A
Nom. Tons: 2; SEER: 13; EER: 11; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Width: 24-1/8"; Height: 32"; Depth: 18-1/2"; Wt. Lbs.: 180;
Brand: National Comfort Products Mfg #: NCPE-424-3010

Air Conditioning Condensing Unit Thru-The-Wall-14 SEER, Single-Phase, 1 Ton, R410A B63-652
Air Conditioning Condensing Unit Thru-The-Wall-14 SEER, Single-Phase, 1 Ton, R410A
Nom. Tons: 1; SEER: 14; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Width: 29-1/2"; Height: 23"; Depth: 22"; Wt. Lbs.: 125;
Brand: First Co Mfg #: 12WCX14-CB

Replacement for Intercity Draft Inducer Blower X89-977
Replacement for Intercity Draft Inducer Blower
HP: 1/18; Volts: 115; RPM: 3450; F/L Amps: 0.8; Rot.: CCW; Bearing Type: Ball; Safety Switch: No; Replaces: 1011350 and R7-RFB350; Wt. Lbs.: 11.20;
Brand: Fasco Mfg #: A173

Replacement for Carrier Draft Inducer Blower X83-393
Replacement for Carrier Draft Inducer Blower
Motor Type: PSC; HP: 1/16; Volts: 208-230; RPM: 3450; Speeds: 1; F/L Amps: 0.5; Rot.: CWLE; Bearing Type: Ball; Safety Switch: Auto Top; Replaces: Carrier HC30CK234, HC30GB232, 48GS400106, 48GS400649; CFM: 179; Outlet Flange: Square; Wt. Lbs.: 7.85;
Brand: Packard Mfg #: 66649

Replacement for Goodman Draft Inducer Blower X89-978
Replacement for Goodman Draft Inducer Blower
HP: 1/30; Volts: 115; RPM: 3400; Speeds: 1; F/L Amps: 1.8; Rot.: CCW; Bearing Type: Ball; Safety Switch: No; Replaces: Goodman 201-90601; Wt. Lbs.: 7.00;
Brand: Fasco Mfg #: A180

Air Conditioning Condensing Unit Thru-The-Wall 12 SEER, Single-Phase, 2.5 TON, R410A B61-350
Air Conditioning Condensing Unit Thru-The-Wall 12 SEER, Single-Phase, 2.5 TON, R410A
Nom. Tons: 2.5; SEER: 12; EER: 10.5; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Width: 24-1/8"; Height: 32"; Depth: 18-1/2"; Wt. Lbs.: 180;
Brand: National Comfort Products Mfg #: NCPE-430-3010

Replacement for York Draft Inducer Blower X82-124
Replacement for York Draft Inducer Blower
HP: 1/15; Volts: 115; RPM: 3200; F/L Amps: 2.25; Rot.: CW; Bearing Type: Slv; Safety Switch: No; Replaces: 7058-0266, 7058-0266S; Wt. Lbs.: 4.80;
Brand: Fasco Mfg #: A225

Replacement for Trane Draft Inducer Blowers X89-983
Replacement for Trane Draft Inducer Blowers
HP: 1/16; Volts: 115; RPM: 3400; F/L Amps: 1.80; Rot.: CW; Bearing Type: Ball; Safety Switch: No; Replaces: D330757P03, D342094P03, X38040313070; Wt. Lbs.: 6.20;
Brand: Fasco Mfg #: A195

Thru-the-Wall Package Unit Comfort Pack Series, Gas Heat, 80% AFUE, 12 SEER, R410A B62-014
Thru-the-Wall Package Unit Comfort Pack Series, Gas Heat, 80% AFUE, 12 SEER, R410A
Type: Gas Heat; Volts: 208/230; BtuH Cooling: 22,000; BtuH Heating: 40,800; Air Delivery CFM: 850; Fan Speeds: 5; Amps Cooling: 14.7; Amps Heating: 3.9; Fuse Size T.D.: 25; Width: 28"; Height: 43"; Depth: 31-15/32"; Wt. Lbs.: 310;
Brand: National Comfort Products Mfg #: CPG42351-U

Thru-the-Wall Package Unit Comfort Pack Series, Gas Heat, 80% AFUE, 12 SEER, R410A B62-010
Thru-the-Wall Package Unit Comfort Pack Series, Gas Heat, 80% AFUE, 12 SEER, R410A
Type: Gas Heat; Volts: 208/230; BtuH Cooling: 17,500; BtuH Heating: 30,400; Air Delivery CFM: 780; Fan Speeds: 5; Amps Cooling: 11.3; Amps Heating: 3; Fuse Size T.D.: 15; Width: 28"; Height: 43"; Depth: 31-15/32"; Wt. Lbs.: 310;
Brand: National Comfort Products Mfg #: CPG41738-U

General Purpose Draft Inducer Blower S88-385
General Purpose Draft Inducer Blower
HP: 1/65; Volts: 115/230; RPM: 3000; F/L Amps: 0.9/0.4; Rot.: CCWSE; Bearing Type: Ball; Safety Switch: Yes; Wt. Lbs.: 5.0;
Brand: Fasco Mfg #: B23618

Replacement for Trane Draft Inducer Blowers X82-145
Replacement for Trane Draft Inducer Blowers
HP: 1/35; Volts: 208-230; RPM: 2500/3000; F/L Amps: 0.58-0.60; Rot.: CCW; Bearing Type: Ball; Safety Switch: No; Replaces: 7021-11054; Wt. Lbs.: 7.30;
Brand: Fasco Mfg #: A269

Replacement for Trane Draft Inducer Blower X89-564
Replacement for Trane Draft Inducer Blower
HP: 1/20; Volts: 115; RPM: 3450; F/L Amps: 0.70; Rot.: CWSE; Bearing Type: Slv; Safety Switch: No; Replaces: 7062-3956; Wt. Lbs.: 5.00;
Brand: Fasco Mfg #: A130

Air Conditioning Condensing Unit Thru-The-Wall 12.5 SEER, Single-Phase, 2 TON, R410A B61-346
Air Conditioning Condensing Unit Thru-The-Wall 12.5 SEER, Single-Phase, 2 TON, R410A
Nom. Tons: 2; SEER: 12.5; EER: 11; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Width: 26-1/4"; Height: 28-5/8"; Depth: 18-1/2"; Wt. Lbs.: 180;
Brand: National Comfort Products Mfg #: NCPE-424-1010

Replacement for Lennox Draft Inducer Blower X89-985
Replacement for Lennox Draft Inducer Blower
HP: 1/30; Volts: 115; RPM: 3400; Speeds: 1; F/L Amps: 1.8; Rot.: CCW; Bearing Type: Ball; Safety Switch: No; Replaces: 45037-001, 45037-1P and 46087-001; Wt. Lbs.: 4.50;
Brand: Fasco Mfg #: A202

Thru-the-Wall Heat Pump 12 SEER, Single-Phase, 2 Ton, R410A B61-341
Thru-the-Wall Heat Pump 12 SEER, Single-Phase, 2 Ton, R410A
Nom. Tons: 2; SEER: 12; EER: 10.5; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Width: 24-1/8"; Height: 32"; Depth: 18-1/2"; Wt. Lbs.: 180;
Brand: National Comfort Products Mfg #: NHPA-424-3019

Air Conditioning Condensing Unit Thru-The-Wall 13 SEER, Single-Phase, 1.5 TON, R410A B61-348
Air Conditioning Condensing Unit Thru-The-Wall 13 SEER, Single-Phase, 1.5 TON, R410A
Nom. Tons: 1.5; SEER: 13; EER: 11.5; Max. Fuse Size: 20; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Width: 24-1/8"; Height: 32"; Depth: 18-1/2"; Wt. Lbs.: 180;
Brand: National Comfort Products Mfg #: NCPE-418-3010
FTL Finance
Powered by Site Search powered by SLI Systems
Select products to compare.