104 Results

1, 5, 3-1/2, 2, 11 to 11.9

Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 5 Ton, R410A, 81% AFUE B64-202
Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 5 Ton, R410A, 81% AFUE
SEER: 14; EER: 11.2; Nom. Tons: 5; BtuH Cooling: 56,500; BtuH Heating Input: 100,000; BtuH Heating Output: 80,000; Volts: 208/230V; Phase: Single; Nom. CFM: 1,810; Min. Circuit Amps: 36.5; Refrigerant: R410A; Width: 35-3/4"; Height: 50"; Depth: 51-1/4"; Wt. Lbs.: 475;
Brand: Coleman Mfg #: PCG4B601002X4

Heat Pump 15 SEER, Single-Phase, 2 Ton, R410A B65-707
Heat Pump 15 SEER, Single-Phase, 2 Ton, R410A
SEER: 15; EER: 11.2; Nom. Tons: 2; BtuH Cooling: 24,000; BtuH Heating Input: 24,000; Volts: 208/230; Phase: Single; HSPF: 9.0; Min. Circuit Amps: 22.9; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 28"; Height: 24-15/16"; Depth: 28"; Wt. Lbs.: 126;
Brand: Bosch Mfg #: BOVA24HDN1M15G

Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 2 Ton, R410A, 81% AFUE B64-190
Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 2 Ton, R410A, 81% AFUE
SEER: 14; EER: 11.0; Nom. Tons: 2; BtuH Cooling: 23,600; BtuH Heating Input: 75,000; BtuH Heating Output: 60,000; Volts: 208/230V; Phase: Single; Nom. CFM: 775; Min. Circuit Amps: 18.1; Refrigerant: R410A; Width: 35-3/4"; Height: 44"; Depth: 51-1/4"; Wt. Lbs.: 336;
Brand: Coleman Mfg #: PCG4A240752X4

Single Packaged Heat Pump 14 SEER, 5 Ton, Single-Phase, R410A B64-163
Single Packaged Heat Pump 14 SEER, 5 Ton, Single-Phase, R410A
SEER: 14; EER: 11.6; Nom. Tons: 5; BtuH Cooling: 59,500; BtuH Heating Input: 56,500; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 3.6; Nom. CFM: 1,850; Min. Circuit Amps: 36.5; Refrigerant: R410A; Width: 45-3/4"; Height: 55"; Depth: 51-1/4"; Wt. Lbs.: 485;
Brand: Coleman Mfg #: PHE4B6024

Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 5 Ton, R410A, 81% AFUE B64-203
Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 5 Ton, R410A, 81% AFUE
SEER: 14; EER: 11.2; Nom. Tons: 5; BtuH Cooling: 56,500; BtuH Heating Input: 125,000; BtuH Heating Output: 100,000; Volts: 208/230V; Phase: Single; Nom. CFM: 1,810; Min. Circuit Amps: 36.5; Refrigerant: R410A; Width: 35-3/4"; Height: 50"; Depth: 51-1/4"; Wt. Lbs.: 479;
Brand: Coleman Mfg #: PCG4B601252X4

Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 3.5 Ton, R410A, 81% AFUE B64-197
Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 3.5 Ton, R410A, 81% AFUE
SEER: 14; EER: 11.2; Nom. Tons: 3-1/2; BtuH Cooling: 41,500; BtuH Heating Input: 100,000; BtuH Heating Output: 80,000; Volts: 208/230V; Phase: Single; Nom. CFM: 1,350; Min. Circuit Amps: 27.0; Refrigerant: R410A; Width: 35-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 402;
Brand: Coleman Mfg #: PCG4A421002X4

Single Packaged Heat Pump 14 SEER, 3-1/2 Ton, Single-Phase, R410A B64-161
Single Packaged Heat Pump 14 SEER, 3-1/2 Ton, Single-Phase, R410A
SEER: 14; EER: 11.6; Nom. Tons: 3-1/2; BtuH Cooling: 42,000; BtuH Heating Input: 39,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 3.6; Nom. CFM: 1,350; Min. Circuit Amps: 27.0; Refrigerant: R410A; Width: 45-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 436;
Brand: Coleman Mfg #: PHE4B4224

Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 2 Ton, R410A B62-069
Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 2 Ton, R410A
SEER: 13; EER: 11.0; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 11.4; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 24"; Height: 26-3/4"; Depth: 24"; Wt. Lbs.: 130; OEM TXV: B20-469; OEM TXV for…
Brand: Coleman Mfg #: TC3B2423S

Single Packaged Heat Pump 14 SEER, 2 Ton, Single-Phase, R410A B64-158
Single Packaged Heat Pump 14 SEER, 2 Ton, Single-Phase, R410A
SEER: 14; EER: 11.6; Nom. Tons: 2; BtuH Cooling: 25,000; BtuH Heating Input: 23,600; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 3.7; Nom. CFM: 780; Min. Circuit Amps: 18.6; Refrigerant: R410A; Width: 35-3/4"; Height: 44"; Depth: 51-1/4"; Wt. Lbs.: 330;
Brand: Coleman Mfg #: PHE4A2424

Single Packaged Air Conditioner 14 SEER, Single-Phase, 5 Ton, R410A B64-147
Single Packaged Air Conditioner 14 SEER, Single-Phase, 5 Ton, R410A
SEER: 14; EER: 11.2; Nom. Tons: 5; BtuH Cooling: 56,500; Volts: 208/230; Phase: Single; Motor Type: ECM; Nom. CFM: 1,810; Min. Circuit Amps: 36.5; Max. Fuse Size: 50; Refrigerant: R410A; Width: 45-3/4"; Height: 50"; Depth: 51-1/4"; Wt. Lbs.: 450;
Brand: Coleman Mfg #: PCE4B6024

Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 2 Ton, R410A, 81% AFUE B64-189
Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 2 Ton, R410A, 81% AFUE
SEER: 14; EER: 11.0; Nom. Tons: 2; BtuH Cooling: 23,600; BtuH Heating Input: 50,000; BtuH Heating Output: 40,000; Volts: 208/230V; Phase: Single; Nom. CFM: 775; Min. Circuit Amps: 16.9; Refrigerant: R410A; Width: 35-3/4"; Height: 44"; Depth: 51-1/4"; Wt. Lbs.: 316;
Brand: Coleman Mfg #: PCG4A240502X4

Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 3.5 Ton, R410A, 81% AFUE B64-196
Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 3.5 Ton, R410A, 81% AFUE
SEER: 14; EER: 11.2; Nom. Tons: 3-1/2; BtuH Cooling: 41,500; BtuH Heating Input: 75,000; BtuH Heating Output: 60,000; Volts: 208/230V; Phase: Single; Nom. CFM: 1,350; Min. Circuit Amps: 27.0; Refrigerant: R410A; Width: 35-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 398;
Brand: Coleman Mfg #: PCG4A420752X4

Single Packaged Air Conditioner 14 SEER, Single-Phase, 2 Ton, R410A B64-142
Single Packaged Air Conditioner 14 SEER, Single-Phase, 2 Ton, R410A
SEER: 14; EER: 11.0; Nom. Tons: 2; BtuH Cooling: 23,600; Volts: 208/230; Phase: Single; Motor Type: ECM; Nom. CFM: 775; Min. Circuit Amps: 18.1; Max. Fuse Size: 25; Refrigerant: R410A; Width: 35-3/4"; Height: 44"; Depth: 51-1/4"; Wt. Lbs.: 307;
Brand: Coleman Mfg #: PCE4A2424

Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 5 Ton, R410A, 81% AFUE B64-201
Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 5 Ton, R410A, 81% AFUE
SEER: 14; EER: 11.2; Nom. Tons: 5; BtuH Cooling: 56,500; BtuH Heating Input: 65,000; BtuH Heating Output: 52,000; Volts: 208/230V; Phase: Single; Nom. CFM: 1,810; Min. Circuit Amps: 36.5; Refrigerant: R410A; Width: 35-3/4"; Height: 50"; Depth: 51-1/4"; Wt. Lbs.: 469;
Brand: Coleman Mfg #: PCG4B600652X4

Heat Pump 14 SEER, Single-Phase, 2 Ton, R410A B75-914
Heat Pump 14 SEER, Single-Phase, 2 Ton, R410A
SEER: 14; EER: 11.5; Nom. Tons: 2; BtuH Cooling: 24,000; BtuH Heating Input: 24,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.2; COP: 4.39; Min. Circuit Amps: 10.6; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29"; Height: 34-1/2"; Depth:…
Brand: Goodman Mfg #: GSZ140241

Single Packaged Air Conditioner 14 SEER, Single-Phase, 3-1/2 Ton, R410A B64-145
Single Packaged Air Conditioner 14 SEER, Single-Phase, 3-1/2 Ton, R410A
SEER: 14; EER: 11.2; Nom. Tons: 3-1/2; BtuH Cooling: 41,500; Volts: 208/230; Phase: Single; Motor Type: ECM; Nom. CFM: 1,350; Min. Circuit Amps: 27.0; Max. Fuse Size: 40; Refrigerant: R410A; Width: 35-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 369;
Brand: Coleman Mfg #: PCE4A4224

Air Conditioning Condensing Unit 13 SEER, Single-Phase, 3-1/2 Ton, R410A B98-348
Air Conditioning Condensing Unit 13 SEER, Single-Phase, 3-1/2 Ton, R410A
SEER: 13; EER: 11.0; Nom. Tons: 3-1/2; BtuH Cooling: 42,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 23.6; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 29"; Height: 36-1/4"; Depth: 29"; Wt. Lbs.: 171; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSX130421

Heat Pump 14 SEER, Single-Phase, 3-1/2 Ton, R410A B75-917
Heat Pump 14 SEER, Single-Phase, 3-1/2 Ton, R410A
SEER: 14; EER: 11.5; Nom. Tons: 3-1/2; BtuH Cooling: 42,000; BtuH Heating Input: 42,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.2; COP: 4.44; Min. Circuit Amps: 22.0; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 35-1/2"; Height:…
Brand: Goodman Mfg #: GSZ140421

Air Conditioning Condensing Unit 13 SEER, Single-Phase, 2 Ton, R410A B61-811
Air Conditioning Condensing Unit 13 SEER, Single-Phase, 2 Ton, R410A
SEER: 13; EER: 11.0; Nom. Tons: 2; BtuH Cooling: 23,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 10.3; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 23"; Height: 27-1/2"; Depth: 23"; Wt. Lbs.: 103; OEM TXV: B18-099;
Brand: Goodman Mfg #: GSX130241

Air Conditioning Condensing Unit 13 SEER, Single-Phase, 5 Ton, R410A B98-350
Air Conditioning Condensing Unit 13 SEER, Single-Phase, 5 Ton, R410A
SEER: 13; EER: 11.0; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 32.5; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 29"; Height: 40"; Depth: 29"; Wt. Lbs.: 184; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSX130601

Heat Pump 14 SEER, Single-Phase, 5 Ton, R410A B75-919
Heat Pump 14 SEER, Single-Phase, 5 Ton, R410A
SEER: 14; EER: 11.5; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 9.0; COP: 4.52; Min. Circuit Amps: 34.3; Max. Fuse Size: 60; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 35-1/2"; Height: 34-1/2";…
Brand: Goodman Mfg #: GSZ140601

Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 5 Ton, R410A B62-070
Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 5 Ton, R410A
SEER: 13; EER: 11.0; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 29.1; Max. Fuse Size: 60; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 29-1/4"; Height: 36-1/4"; Depth: 29-1/4"; Wt. Lbs.: 190; OEM TXV: B19-660;…
Brand: Coleman Mfg #: TC3B6022S

Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 3-1/2 Ton, R410A B62-201
Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 3-1/2 Ton, R410A
SEER: 13; EER: 11.25; Nom. Tons: 3-1/2; BtuH Cooling: 42,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 21.1; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 29-1/4"; Height: 30"; Depth: 29-1/4"; Wt. Lbs.: 175; OEM TXV: B19-659; OEM…
Brand: Coleman Mfg #: TC3B4223S

Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 5 Ton, R410A B77-529
Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 5 Ton, R410A
SEER: 13; EER: 11; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 34.3; Max. Fuse Size: 60; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 29-1/4"; Height: 36-1/4"; Depth: 29-1/4"; Wt. Lbs.: 185; OEM TXV: B19-660; OEM…
Brand: Evcon Mfg #: RAC13L60B23S
FTL Finance
Powered by Site Search powered by SLI Systems
Select products to compare.