144 Results

14, 4, 2-1/2

Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 4 Ton, R407C B79-034
Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 4 Ton, R407C
SEER: 14; EER: 11.75; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 26.1; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R407C; Width: 38"; Height: 36-1/4"; Depth: 34-1/4"; Wt. Lbs.: 200; OEM TXV: B15-138; OEM TXV…
Brand: Evcon Mfg #: GAW14L48C23S

Heat Pump Up To 15 SEER, Single-Phase, 2-1/2 Ton, R410A B76-768
Heat Pump Up To 15 SEER, Single-Phase, 2-1/2 Ton, R410A
SEER: 14; EER: 11.5; Nom. Tons: 2-1/2; BtuH Cooling: 30,000; BtuH Heating Input: 30,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.5; COP: 4.39; Min. Circuit Amps: 17.8; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29"; Height: 36-1/4";…
Brand: Amana Mfg #: ASZ140301

Air Conditioning Condensing Unit 14 SEER, Single-Phase, 4 Ton, R410A B76-753
Air Conditioning Condensing Unit 14 SEER, Single-Phase, 4 Ton, R410A
SEER: 14; EER: 11.7; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 26.2; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 38-1/4"; Depth: 35-1/2"; Wt. Lbs.: 220; OEM TXV: B14-851;
Brand: Amana Mfg #: ASX140481

Heat Pump Up To 15 SEER, Single-Phase, 4 Ton, R410A B76-771
Heat Pump Up To 15 SEER, Single-Phase, 4 Ton, R410A
SEER: 14; EER: 11.5; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 48,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 9.0; COP: 4.72; Min. Circuit Amps: 24.4; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 29"; Height: 36-1/4";…
Brand: Amana Mfg #: ASZ140481

14 SEER Air Conditioner 2-1/2 Ton B79-090
14 SEER Air Conditioner 2-1/2 Ton
SEER: 14; EER: 11.5; Nom. Tons: 2-1/2; BtuH Cooling: 30,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 14.1; Max. Fuse Size: 20; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29"; Height: 32-1/2"; Depth: 29"; Wt. Lbs.: 162; OEM TXV: B14-850;
Brand: Goodman Mfg #: VSX140301

Air Conditioning Condensing Unit 14 SEER, Single-Phase, 2-1/2 Ton, R410A B76-749
Air Conditioning Condensing Unit 14 SEER, Single-Phase, 2-1/2 Ton, R410A
SEER: 14; EER: 12.2; Nom. Tons: 2-1/2; BtuH Cooling: 30,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 17.0; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29"; Height: 32-1/2"; Depth: 29"; Wt. Lbs.: 180; OEM TXV: B14-850;
Brand: Amana Mfg #: ASX140311

Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 2-1/2 Ton, R410A, Fin Tube, Southeast Region Only B77-441
Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 2-1/2 Ton, R410A, Fin Tube, Southeast Region Only
SEER: 14; EER: 11.7; Nom. Tons: 2-1/2; BtuH Cooling: 30,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 18.1; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 35-1/4"; Height: 39-1/2"; Depth: 31-3/4"; Wt. Lbs.: 176; OEM TXV: B19-658;…
Brand: Coleman Mfg #: TF4B3021S

Heat Pump GMC Series, 14 SEER, Single-Phase, 4 Ton, R410A B75-932
Heat Pump GMC Series, 14 SEER, Single-Phase, 4 Ton, R410A
SEER: 14; EER: 11.5; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 48,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 9; COP: 4.72; Min. Circuit Amps: 24.4; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 29"; Height: 36-1/4";…
Brand: Goodman Mfg #: VSZ140481

Single Packaged Heat Pump 14 SEER, 4 Ton, Single-Phase, R410A B77-233
Single Packaged Heat Pump 14 SEER, 4 Ton, Single-Phase, R410A
SEER: 14; EER: 11; Nom. Tons: 4; BtuH Cooling: 45,500; BtuH Heating Input: 44,100; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8; COP: 3.5; Nom. CFM: 1,600; Min. Circuit Amps: 34.4; Refrigerant: R410A; Width: 45-3/4"; Height: 53"; Depth: 51-1/4"; Wt. Lbs.: 496;
Brand: Coleman Mfg #: PHE4A4821

Single Packaged Gas/Heat Air Conditioner 14 SEER, Three-Phase, 4 Ton, R410A, 81% AFUE, 208/230V, LOWNOx B63-660
Single Packaged Gas/Heat Air Conditioner 14 SEER, Three-Phase, 4 Ton, R410A, 81% AFUE, 208/230V, LOWNOx
SEER: 14; EER: 11.2; Nom. Tons: 4; BtuH Cooling: 45,500; BtuH Heating Input: 65,000; BtuH Heating Output: 53,000; Volts: 208/230V; Phase: Three; Nom. CFM: 1,600; Min. Circuit Amps: 20.1; Refrigerant: R410A; Width: 45-3/4; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 460;
Brand: Coleman Mfg #: PCG4B480653L1

Single Packaged Gas/Heat Air Conditioner 14 SEER, Three-Phase, 4 Ton, R410A, 81% AFUE, 460V, LOWNOx B63-663
Single Packaged Gas/Heat Air Conditioner 14 SEER, Three-Phase, 4 Ton, R410A, 81% AFUE, 460V, LOWNOx
SEER: 14; EER: 11.2; Nom. Tons: 4; BtuH Cooling: 45,500; BtuH Heating Input: 65,000; BtuH Heating Output: 53,000; Volts: 460V; Phase: Three; Nom. CFM: 1,600; Min. Circuit Amps: 11.5; Refrigerant: R410A; Width: 45-3/4; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 460;
Brand: Coleman Mfg #: PCG4B480654L1

Heat Pump GMC Series, 14 SEER, Single-Phase, 2-1/2 Ton, R410A B75-929
Heat Pump GMC Series, 14 SEER, Single-Phase, 2-1/2 Ton, R410A
SEER: 14; EER: 11.5; Nom. Tons: 2-1/2; BtuH Cooling: 36,000; BtuH Heating Input: 36,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.5; COP: 4.39; Min. Circuit Amps: 17.8; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29"; Height: 36-1/4";…
Brand: Goodman Mfg #: VSZ140301

Air Conditioning Condensing Unit GMC Series, 14 SEER, Single-Phase, 2-1/2 Ton, R410A B76-584
Air Conditioning Condensing Unit GMC Series, 14 SEER, Single-Phase, 2-1/2 Ton, R410A
SEER: 14; EER: 12.2; Nom. Tons: 2-1/2; BtuH Cooling: 30,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 17.0; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29"; Height: 32-1/2"; Depth: 29"; Wt. Lbs.: 162; OEM TXV: B14-850;
Brand: Goodman Mfg #: VSX140311

Single Packaged Air Conditioner 14 SEER, Three-Phase, 4 Ton, R410A B61-590
Single Packaged Air Conditioner 14 SEER, Three-Phase, 4 Ton, R410A
SEER: 14; EER: 11.0; Nom. Tons: 4; BtuH Cooling: 45,500; Volts: 460; Phase: Three; Motor Type: ECM; Nom. CFM: 1,600; Min. Circuit Amps: 27.6; Max. Fuse Size: 30; Refrigerant: R410A; Width: 45-3/4"; Height: 49"; Depth: 51-1/4"; Wt. Lbs.: 455;
Brand: Coleman Mfg #: PCE4B4842

Single Packaged Gas/Heat Air Conditioner LX Series, 14 SEER, Single-Phase, 4 Ton, R410A, 81% AFUE B61-587
Single Packaged Gas/Heat Air Conditioner LX Series, 14 SEER, Single-Phase, 4 Ton, R410A, 81% AFUE
SEER: 14; EER: 11.2; Nom. Tons: 4; BtuH Cooling: 45,500; BtuH Heating Input: 100,000; BtuH Heating Output: 80,000; Volts: 208/230V; Phase: Single; Nom. CFM: 1,600; Min. Circuit Amps: 34.4; Refrigerant: R410A; Width: 45-3/4"; Height: 49"; Depth: 51"; Wt. Lbs.: 473;
Brand: Coleman Mfg #: PCG4B481252X2

Manufactured Housing Air Conditioning Condensing Unit 14 SEER Sweat Fit 2-1/2 Ton, R410A B60-928
Manufactured Housing Air Conditioning Condensing Unit 14 SEER Sweat Fit 2-1/2 Ton, R410A
Nom. Tons: 2-1/2; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Width: 35-1/2"; Height: 31"; Depth: 35-1/2"; Wt. Lbs.: 159; SEER: 14;
Brand: Maytag Mfg #: RSCS304

Manufactured Housing Air Conditioning Condensing Unit 14 SEER AccuCharge® 4 Ton, R410A B60-919
Manufactured Housing Air Conditioning Condensing Unit 14 SEER AccuCharge® 4 Ton, R410A
Nom. Tons: 4; Min. Circuit Amps: 26.2; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Width: 35-1/2"; Height: 43"; Depth: 35-1/2"; Wt. Lbs.: 212; SEER: 14;
Brand: Maytag Mfg #: RSCQ484

Manufactured Housing Air Conditioning Condensing Unit 14 SEER AccuCharge® 2-1/2 Ton, R410A B60-916
Manufactured Housing Air Conditioning Condensing Unit 14 SEER AccuCharge® 2-1/2 Ton, R410A
Nom. Tons: 2-1/2; Min. Circuit Amps: 13.3; Max. Fuse Size: 20; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Width: 35-1/2"; Height: 31"; Depth: 35-1/2"; Wt. Lbs.: 165; SEER: 14;
Brand: Maytag Mfg #: RSCQ304

Manufactured Housing Heat Pump 14 SEER, 4 Ton, Single-Phase, R410A, Sweat Fit B60-942
Manufactured Housing Heat Pump 14 SEER, 4 Ton, Single-Phase, R410A, Sweat Fit
Nom. Tons: 4; Min. Circuit Amps: 26.3; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Width: 35-1/2"; Height: 47"; Depth: 35-1/2"; Wt. Lbs.: 247; SEER: 14;
Brand: Maytag Mfg #: RSHS484

Manufactured Housing Heat Pump 14 SEER, 2-1/2Ton, Single-Phase, R410A, Quick Connect B60-934
Manufactured Housing Heat Pump 14 SEER, 2-1/2Ton, Single-Phase, R410A, Quick Connect
Nom. Tons: 2-1/2; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Width: 35-1/2"; Height: 43"; Depth: 35-1/2"; Wt. Lbs.: 189; SEER: 14;
Brand: Maytag Mfg #: RSHQ304

Manufactured Housing Heat Pump 14 SEER, 2-1/2Ton, Single-Phase, R410A, Sweat Fit B60-939
Manufactured Housing Heat Pump 14 SEER, 2-1/2Ton, Single-Phase, R410A, Sweat Fit
Nom. Tons: 2-1/2; Min. Circuit Amps: 16.9; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Width: 35-1/2"; Height: 43"; Depth: 35-1/2"; Wt. Lbs.: 189; SEER: 14;
Brand: Maytag Mfg #: RSHS304

Manufactured Housing Heat Pump 14 SEER, 4 Ton, Single-Phase, R410A, Quick Connect B60-937
Manufactured Housing Heat Pump 14 SEER, 4 Ton, Single-Phase, R410A, Quick Connect
Nom. Tons: 4; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Width: 35-1/2"; Height: 47"; Depth: 35-1/2"; Wt. Lbs.: 234; SEER: 14;
Brand: Maytag Mfg #: RSHQ484

Manufactured Housing Air Conditioning Condensing Unit 14 SEER Sweat Fit 4 Ton, R410A B60-931
Manufactured Housing Air Conditioning Condensing Unit 14 SEER Sweat Fit 4 Ton, R410A
Nom. Tons: 4; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Width: 35-1/2"; Height: 43"; Depth: 35-1/2"; Wt. Lbs.: 206; SEER: 14;
Brand: Maytag Mfg #: RSCS484

Manufactured Housing Air Conditioning Condensing Unit 14 SEER, 2.5 Ton, Single-Phase, R410A B61-272
Manufactured Housing Air Conditioning Condensing Unit 14 SEER, 2.5 Ton, Single-Phase, R410A
Nom. Tons: 2-1/2; Min. Circuit Amps: 14.2; Max. Fuse Size: 20; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Width: 29-1/4"; Height: 30"; Depth: 29-1/4"; Wt. Lbs.: 155; SEER: 14;
Brand: Coleman Mfg #: QC4B30B22S