288 Results

1, 5, 3-1/2

Heat Pump 16 SEER, Two-Stage, Single-Phase, 5 Tons, R410A B61-614
Heat Pump 16 SEER, Two-Stage, Single-Phase, 5 Tons, R410A
SEER: 16; EER: 12.50; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.5; COP: 4.83; Min. Circuit Amps: 31.4; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 35-1/2"; Height: 40";…
Brand: Goodman Mfg #: GSZC160601

Heat Pump 16 SEER, Single-Phase, 5 Ton, R410A B61-221
Heat Pump 16 SEER, Single-Phase, 5 Ton, R410A
SEER: 16; EER: 13; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.0; COP: 3.36; Min. Circuit Amps: 32.4; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 38"; Height: 46"; Depth:…
Brand: Coleman Mfg #: CH6B6021S

Single Packaged Heat Pump 14 SEER, 3-1/2 Ton, Single-Phase, R410A B64-161
Single Packaged Heat Pump 14 SEER, 3-1/2 Ton, Single-Phase, R410A
SEER: 14; EER: 11.6; Nom. Tons: 3-1/2; BtuH Cooling: 42,000; BtuH Heating Input: 39,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 3.6; Nom. CFM: 1,350; Min. Circuit Amps: 27.0; Refrigerant: R410A; Width: 45-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 436;
Brand: Coleman Mfg #: PHE4B4224

Single Packaged Air Conditioner 14 SEER, Single-Phase, 5 Ton, R410A B64-147
Single Packaged Air Conditioner 14 SEER, Single-Phase, 5 Ton, R410A
SEER: 14; EER: 11.2; Nom. Tons: 5; BtuH Cooling: 56,500; Volts: 208/230; Phase: Single; Motor Type: ECM; Nom. CFM: 1,810; Min. Circuit Amps: 36.5; Max. Fuse Size: 50; Refrigerant: R410A; Width: 45-3/4"; Height: 50"; Depth: 51-1/4"; Wt. Lbs.: 450;
Brand: Coleman Mfg #: PCE4B6024

Heat Pump 18 SEER, Two-Stage, Single-Phase, 5 Tons, R410A B61-610
Heat Pump 18 SEER, Two-Stage, Single-Phase, 5 Tons, R410A
SEER: 18; EER: 12.5; Nom. Tons: 5; BtuH Cooling: 56,500; BtuH Heating Input: 59,500; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.5; COP: 4.44; Min. Circuit Amps: 31.4; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 35-1/2"; Height: 40";…
Brand: Goodman Mfg #: GSZC180601

Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 3.5 Ton, R410A, 81% AFUE B64-196
Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 3.5 Ton, R410A, 81% AFUE
SEER: 14; EER: 11.2; Nom. Tons: 3-1/2; BtuH Cooling: 41,500; BtuH Heating Input: 75,000; BtuH Heating Output: 60,000; Volts: 208/230V; Phase: Single; Nom. CFM: 1,350; Min. Circuit Amps: 27.0; Refrigerant: R410A; Width: 35-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 398;
Brand: Coleman Mfg #: PCG4A420752X4

Air Conditioning Condensing Unit 20 SEER, Single-Phase, Modulating, 5 Ton, R410A B79-688
Air Conditioning Condensing Unit 20 SEER, Single-Phase, Modulating, 5 Ton, R410A
SEER: 20; EER: 12.75; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 33.9; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 34-1/2"; Height: 46-1/2"; Depth: 38-1/4"; Wt. Lbs.: 270;
Brand: Coleman Mfg #: AC21B6021S

Single Packaged Gas/Heat Air Conditioner LX Series, 16 SEER, Single-Phase, 5 Ton, R410A, 81% AFUE B64-230
Single Packaged Gas/Heat Air Conditioner LX Series, 16 SEER, Single-Phase, 5 Ton, R410A, 81% AFUE
SEER: 16; EER: 12.0; Nom. Tons: 5; BtuH Cooling: 59,000; BtuH Heating Input: 65,000; BtuH Heating Output: 52,000; Volts: 208/230; Phase: Single; Nom. CFM: 1,825; Min. Circuit Amps: 38.0; Refrigerant: R410A; Width: 45-3/4"; Height: 50"; Depth: 51-1/4"; Wt. Lbs.: 537;
Brand: Coleman Mfg #: PCG6B600652X4

Heat Pump 19 SEER, Single-Phase, Two-Stage, 5 Ton, R410A B60-672
Heat Pump 19 SEER, Single-Phase, Two-Stage, 5 Ton, R410A
SEER: 19; EER: 13.0; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.6; COP: 3.86; Min. Circuit Amps: 31.4; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 34-1/2"; Height: 46-1/2";…
Brand: Coleman Mfg #: HC19B6021S

Air Conditioning Condensing Unit 15.2 SEER2, Single-Phase, 3-1/2 Ton, R410A B65-683
Air Conditioning Condensing Unit 15.2 SEER2, Single-Phase, 3-1/2 Ton, R410A
SEER2: 15.2; Nom. Tons: 3-1/2; BtuH Cooling: 42,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 23.4; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 36-1/2"; Depth: 35-1/2"; Wt. Lbs.: 260; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSXH504210

Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 5 Ton, R410A, 81% AFUE B64-201
Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 5 Ton, R410A, 81% AFUE
SEER: 14; EER: 11.2; Nom. Tons: 5; BtuH Cooling: 56,500; BtuH Heating Input: 65,000; BtuH Heating Output: 52,000; Volts: 208/230V; Phase: Single; Nom. CFM: 1,810; Min. Circuit Amps: 36.5; Refrigerant: R410A; Width: 35-3/4"; Height: 50"; Depth: 51-1/4"; Wt. Lbs.: 469;
Brand: Coleman Mfg #: PCG4B600652X4

Single Packaged Air Conditioner 14 SEER, Single-Phase, 3-1/2 Ton, R410A B64-145
Single Packaged Air Conditioner 14 SEER, Single-Phase, 3-1/2 Ton, R410A
SEER: 14; EER: 11.2; Nom. Tons: 3-1/2; BtuH Cooling: 41,500; Volts: 208/230; Phase: Single; Motor Type: ECM; Nom. CFM: 1,350; Min. Circuit Amps: 27.0; Max. Fuse Size: 40; Refrigerant: R410A; Width: 35-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 369;
Brand: Coleman Mfg #: PCE4A4224

Heat Pump 20 SEER, Single-Phase, Modulating, 5 Ton, R410A B79-692
Heat Pump 20 SEER, Single-Phase, Modulating, 5 Ton, R410A
SEER: 20; EER: 12.5; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 10.5; COP: 3.78; Min. Circuit Amps: 33.9; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 34-1/2"; Height:…
Brand: Coleman Mfg #: HC20B6021S

Heat Pump LX Series, 14 SEER, Single-Phase, 3-1/2 Ton, R410A B61-262
Heat Pump LX Series, 14 SEER, Single-Phase, 3-1/2 Ton, R410A
SEER: 14; EER: 12.00; Nom. Tons: 3-1/2; BtuH Cooling: 41,500; BtuH Heating Input: 42,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.3; COP: 3.86; Min. Circuit Amps: 25.5; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/4"; Height:…
Brand: Coleman Mfg #: TH4B4223S

Air Conditioning Condensing Unit 13 SEER, Single-Phase, 3-1/2 Ton, R410A B98-348
Air Conditioning Condensing Unit 13 SEER, Single-Phase, 3-1/2 Ton, R410A
SEER: 13; EER: 11.0; Nom. Tons: 3-1/2; BtuH Cooling: 42,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 23.6; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 29"; Height: 36-1/4"; Depth: 29"; Wt. Lbs.: 171; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSX130421

Heat Pump 14 SEER, Single-Phase, 3-1/2 Ton, R410A B75-917
Heat Pump 14 SEER, Single-Phase, 3-1/2 Ton, R410A
SEER: 14; EER: 11.5; Nom. Tons: 3-1/2; BtuH Cooling: 42,000; BtuH Heating Input: 42,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.2; COP: 4.44; Min. Circuit Amps: 22.0; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 35-1/2"; Height:…
Brand: Goodman Mfg #: GSZ140421

Air Conditioning Condensing Unit 13 SEER, Single-Phase, 5 Ton, R410A B98-350
Air Conditioning Condensing Unit 13 SEER, Single-Phase, 5 Ton, R410A
SEER: 13; EER: 11.0; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 32.5; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 29"; Height: 40"; Depth: 29"; Wt. Lbs.: 184; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSX130601

Single Packaged Heat Pump GPHM3 Series, 13.4 SEER2, Single-Phase, 3-1/2 Ton, R410A, Multi-Position B66-345
Single Packaged Heat Pump GPHM3 Series, 13.4 SEER2, Single-Phase, 3-1/2 Ton, R410A, Multi-Position
SEER2: 13.4; Nom. Tons: 3-1/2; BtuH Cooling: 40,500; BtuH Heating Input: 38,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF2: 6.7; COP: 3.54; Nom. CFM: 1,300; Min. Circuit Amps: 29.2; Refrigerant: R410A; Width: 47"; Height: 42-3/4"; Depth: 51"; Wt. Lbs.: 485;
Brand: Goodman Mfg #: GPHM34241

Heat Pump 14 SEER, Single-Phase, 5 Ton, R410A B75-919
Heat Pump 14 SEER, Single-Phase, 5 Ton, R410A
SEER: 14; EER: 11.5; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 9.0; COP: 4.52; Min. Circuit Amps: 34.3; Max. Fuse Size: 60; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 35-1/2"; Height: 34-1/2";…
Brand: Goodman Mfg #: GSZ140601

Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 5 Ton, R410A B62-070
Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 5 Ton, R410A
SEER: 13; EER: 11.0; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 29.1; Max. Fuse Size: 60; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 29-1/4"; Height: 36-1/4"; Depth: 29-1/4"; Wt. Lbs.: 190; OEM TXV: B19-660;…
Brand: Coleman Mfg #: TC3B6022S

Air Conditioning Condensing Unit 17.2 SEER2, Two-Stage, Single-Phase, 5 Ton, R410A B65-725
Air Conditioning Condensing Unit 17.2 SEER2, Two-Stage, Single-Phase, 5 Ton, R410A
SEER2: 17.2; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 34.8; Max. Fuse Size: 60; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 41-5/8"; Depth: 35-1/2"; Wt. Lbs.: 283; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSXC706010

Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 3-1/2 Ton, R410A B62-201
Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 3-1/2 Ton, R410A
SEER: 13; EER: 11.25; Nom. Tons: 3-1/2; BtuH Cooling: 42,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 21.1; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 29-1/4"; Height: 30"; Depth: 29-1/4"; Wt. Lbs.: 175; OEM TXV: B19-659; OEM…
Brand: Coleman Mfg #: TC3B4223S

Single Packaged Heat Pump GPHM3 Series, 13.4 SEER2, Single-Phase, 5 Ton, R410A, Multi-Position B66-347
Single Packaged Heat Pump GPHM3 Series, 13.4 SEER2, Single-Phase, 5 Ton, R410A, Multi-Position
SEER2: 13.4; Nom. Tons: 5; BtuH Cooling: 56,500; BtuH Heating Input: 55,500; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF2: 6.7; COP: 3.38; Nom. CFM: 1,850; Min. Circuit Amps: 37.5; Refrigerant: R410A; Width: 47"; Height: 42-3/4"; Depth: 51"; Wt. Lbs.: 495;
Brand: Goodman Mfg #: GPHM36041

Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 3-1/2 Ton, R410A B62-223
Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 3-1/2 Ton, R410A
SEER: 13; EER: 12; Nom. Tons: 3-1/2; BtuH Cooling: 41,000; Volts: 208/230; Phase: Single; Min. Circuit Amps: 21.9; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 29-1/4"; Height: 26-3/4"; Depth: 29-1/4"; Wt. Lbs.: 185; OEM TXV: B19-659; OEM TXV for C…
Brand: Evcon Mfg #: RAC13L42B24S