16 Results

16, 5, 3, 2-1/2, 12 to 12.8, Goodman, HVAC Equipment

Heat Pump 16 SEER, Two-Stage, Single-Phase, 5 Tons, R410A B61-614
Heat Pump 16 SEER, Two-Stage, Single-Phase, 5 Tons, R410A
SEER: 16; EER: 12.50; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.5; COP: 4.83; Min. Circuit Amps: 31.4; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 35-1/2"; Height: 40";…
Brand: Goodman Mfg #: GSZC160601

Air Conditioning Condensing Unit 16 SEER, Single-Phase, 2-1/2 Ton, R410A B73-975
Air Conditioning Condensing Unit 16 SEER, Single-Phase, 2-1/2 Ton, R410A
SEER: 16; EER: 12.2; Nom. Tons: 2-1/2; BtuH Cooling: 29,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 17.1; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 29"; Height: 36-1/4"; Depth: 29"; Wt. Lbs.: 149; OEM TXV: B18-724;
Brand: Goodman Mfg #: GSX160301

Air Conditioning Condensing Unit 16 SEER, Single-Phase, 2-1/2 Ton, R410A B75-681
Air Conditioning Condensing Unit 16 SEER, Single-Phase, 2-1/2 Ton, R410A
SEER: 16; EER: 12.5; Nom. Tons: 2-1/2; BtuH Cooling: 30,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 17.1; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 29"; Height: 38-1/4"; Depth: 29"; Wt. Lbs.: 155; OEM TXV: B18-724;
Brand: Goodman Mfg #: GSX160311

Heat Pump 16 SEER, Single-Phase, 5 Ton, R410A B77-557
Heat Pump 16 SEER, Single-Phase, 5 Ton, R410A
SEER: 16; EER: 12.5; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 9.0; COP: 4.45; Min. Circuit Amps: 37.0; Max. Fuse Size: 60; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 35-1/2"; Height: 40";…
Brand: Goodman Mfg #: GSZ160601

Air Conditioning Condensing Unit 16 SEER, Single-Phase, 3 Ton, R410A B73-976
Air Conditioning Condensing Unit 16 SEER, Single-Phase, 3 Ton, R410A
SEER: 16; EER: 12.2; Nom. Tons: 3; BtuH Cooling: 34,800; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 18.7; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 29"; Height: 38-1/4"; Depth: 29"; Wt. Lbs.: 162; OEM TXV: B18-725;
Brand: Goodman Mfg #: GSX160361

Air Conditioning Condensing Unit 16 SEER, Single-Phase, 5 Ton, R410A B73-979
Air Conditioning Condensing Unit 16 SEER, Single-Phase, 5 Ton, R410A
SEER: 16; EER: 12.5; Nom. Tons: 5; BtuH Cooling: 54,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 29.6; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 38-1/4"; Depth: 35-1/2"; Wt. Lbs.: 279; OEM TXV: B18-727;
Brand: Goodman Mfg #: GSX160601

Air Conditioning Condensing Unit 16 SEER, Single-Phase, 3 Ton, R410A B75-682
Air Conditioning Condensing Unit 16 SEER, Single-Phase, 3 Ton, R410A
SEER: 16; EER: 12.5; Nom. Tons: 3; BtuH Cooling: 36,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 20.4; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 36-1/4"; Depth: 35-1/2"; Wt. Lbs.: 182; OEM TXV: B18-725;
Brand: Goodman Mfg #: GSX160371

Single Packaged Heat Pump 16 SEER, Single-Phase, 2-1/2 Ton, R410A, Multi-Position B77-257
Single Packaged Heat Pump 16 SEER, Single-Phase, 2-1/2 Ton, R410A, Multi-Position
SEER: 16; EER: 12.0; Nom. Tons: 2-1/2; BtuH Cooling: 29,000; BtuH Heating Input: 28,400; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 3.5; Nom. CFM: 1,050; Min. Circuit Amps: 22.2; Refrigerant: R410A; Width: 47"; Height: 34-3/4"; Depth: 51"; Wt. Lbs.: 385;
Brand: Goodman Mfg #: GPH1630M41

Single Packaged Heat Pump 16 SEER, Single-Phase, 2-1/2 Ton, R410A, Horizontal B76-932
Single Packaged Heat Pump 16 SEER, Single-Phase, 2-1/2 Ton, R410A, Horizontal
SEER: 16; EER: 12.5; Nom. Tons: 2-1/2; BtuH Cooling: 28,400; BtuH Heating Input: 27,600; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 3.8; Nom. CFM: 1,050; Min. Circuit Amps: 23.0; Refrigerant: R410A; Width: 66"; Height: 30"; Depth: 34"; Wt. Lbs.: 315;
Brand: Goodman Mfg #: GPH1630H41

Single Packaged Gas/Electric Air Conditioner 16 SEER, Single-Phase, 3 Ton, 81% AFUE, R410A, Multi-Position B75-674
Single Packaged Gas/Electric Air Conditioner 16 SEER, Single-Phase, 3 Ton, 81% AFUE, R410A, Multi-Position
SEER: 16; EER: 12.0; Nom. Tons: 3; BtuH Cooling: 34,200; BtuH Heating Input: 80,000; BtuH Heating Output: 62,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Nom. CFM: 1,200; Min. Circuit Amps: 24.4; Refrigerant: R410A; Width: 47"; Height: 42-3/4"; Depth: 51"; Wt. Lbs.: 470;
Brand: Goodman Mfg #: GPG1636080M41

Single Packaged Heat Pump 16 SEER, Single-Phase, 5 Ton, R410A, Multi-Position B63-645
Single Packaged Heat Pump 16 SEER, Single-Phase, 5 Ton, R410A, Multi-Position
SEER: 16; EER: 12.0; Nom. Tons: 5; BtuH Cooling: 58,000; BtuH Heating Input: 58,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.2; COP: 3.7; Nom. CFM: 1,800; Min. Circuit Amps: 44.0; Refrigerant: R410A; Width: 48-49/250"; Height: 42-21/25"; Depth: 73-189/200"; Wt. Lbs.: 688;
Brand: Goodman Mfg #: GPH1660M41

Single Packaged Heat Pump 16 SEER, Single-Phase, 3 Ton, R410A, Multi-Position B77-258
Single Packaged Heat Pump 16 SEER, Single-Phase, 3 Ton, R410A, Multi-Position
SEER: 16; EER: 12.0; Nom. Tons: 3; BtuH Cooling: 33,600; BtuH Heating Input: 33,600; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 3.6; Nom. CFM: 1,200; Min. Circuit Amps: 24.9; Refrigerant: R410A; Width: 47"; Height: 34-3/4"; Depth: 51"; Wt. Lbs.: 438;
Brand: Goodman Mfg #: GPH1636M41

Single Packaged Heat Pump 16 SEER, Single-Phase, 5 Ton, R410A, Horizontal B75-683
Single Packaged Heat Pump 16 SEER, Single-Phase, 5 Ton, R410A, Horizontal
SEER: 16; EER: 12; Nom. Tons: 5; BtuH Cooling: 57,500; BtuH Heating Input: 54,500; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.2; COP: 3.6; Nom. CFM: 1,700; Min. Circuit Amps: 40.0; Refrigerant: R410A; Width: 66"; Height: 38-3/4"; Depth: 34"; Wt. Lbs.: 405;
Brand: Goodman Mfg #: GPH1660H41

Single Packaged Gas/Electric Air Conditioner 16 SEER, Single-Phase, 5 Ton, 81% AFUE, R410A, Multi-Position B63-644
Single Packaged Gas/Electric Air Conditioner 16 SEER, Single-Phase, 5 Ton, 81% AFUE, R410A, Multi-Position
SEER: 16; EER: 12.0; Nom. Tons: 5; BtuH Cooling: 58,000; BtuH Heating Input: 138,000; BtuH Heating Output: 112,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Nom. CFM: 2,000; Min. Circuit Amps: 43.4; Refrigerant: R410A; Width: 48-49/250"; Height: 42-21/25"; Depth: 73-189/200"; Wt. Lbs.: 655;
Brand: Goodman Mfg #: GPG1660140M41

Heat Pump 16 SEER, Two-Stage, Single-Phase, 5 Tons, R410A B91-227
Heat Pump 16 SEER, Two-Stage, Single-Phase, 5 Tons, R410A
SEER: 16; EER: 12.5; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.35; COP: 4.45; Min. Circuit Amps: 37.2; Max. Fuse Size: 60; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 35-1/2"; Height:…
Brand: Goodman Mfg #: DSZC160601

Single Packaged Heat Pump 16 SEER, Single-Phase, 5 Ton, R410A, Multi-Position B79-088
Single Packaged Heat Pump 16 SEER, Single-Phase, 5 Ton, R410A, Multi-Position
SEER: 16; EER: 12.0; Nom. Tons: 5; BtuH Cooling: 58,000; BtuH Heating Input: 55,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.2; COP: 3.8; Nom. CFM: 2,000; Min. Circuit Amps: 42.5; Refrigerant: R410A; Width: 48-49/250"; Height: 42-1/4"; Depth: 73-189/200"; Wt. Lbs.: 612;
Brand: Goodman Mfg #: GPH1660M41SUB
FTL Finance
Powered by Site Search powered by SLI Systems
Select products to compare.