27 Results

16, 12, 5, 3-1/2, 2, Goodman, HVAC Equipment

Heat Pump 16 SEER, Two-Stage, Single-Phase, 5 Tons, R410A B61-614
Heat Pump 16 SEER, Two-Stage, Single-Phase, 5 Tons, R410A
SEER: 16; EER: 12.50; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.5; COP: 4.83; Min. Circuit Amps: 31.4; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 35-1/2"; Height: 40";…
Brand: Goodman Mfg #: GSZC160601

Heat Pump 16 SEER, Two-Stage, Single-Phase, 2 Tons, R410A B61-611
Heat Pump 16 SEER, Two-Stage, Single-Phase, 2 Tons, R410A
SEER: 16; EER: 13.0; Nom. Tons: 2; BtuH Cooling: 24,000; BtuH Heating Input: 24,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.0; COP: 4.96; Min. Circuit Amps: 13.5; Max. Fuse Size: 20; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 35-1/2"; Height: 34-5/8";…
Brand: Goodman Mfg #: GSZC160241

Air Conditioning Condensing Unit 16 SEER, Single-Phase, 2 Ton, R410A B73-974
Air Conditioning Condensing Unit 16 SEER, Single-Phase, 2 Ton, R410A
SEER: 16; EER: 12.2; Nom. Tons: 2; BtuH Cooling: 23,600; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 18.0; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29"; Height: 32-1/4"; Depth: 29"; Wt. Lbs.: 142; OEM TXV: B18-724;
Brand: Goodman Mfg #: GSX160241

Heat Pump 16 SEER, Single-Phase, 2 Ton, R410A B77-552
Heat Pump 16 SEER, Single-Phase, 2 Ton, R410A
SEER: 16; EER: 13.0; Nom. Tons: 2; BtuH Cooling: 24,000; BtuH Heating Input: 24,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 9.0; COP: 4.94; Min. Circuit Amps: 14.7; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 35-1/2"; Height: 34-5/8";…
Brand: Goodman Mfg #: GSZ160241

Heat Pump 16 SEER, Single-Phase, 3-1/2 Ton, R410A B77-555
Heat Pump 16 SEER, Single-Phase, 3-1/2 Ton, R410A
SEER: 16; EER: 13.0; Nom. Tons: 3-1/2; BtuH Cooling: 42,000; BtuH Heating Input: 42,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 9.0; COP: 4.51; Min. Circuit Amps: 22.3; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 29"; Height: 36-3/8";…
Brand: Goodman Mfg #: GSZ160421

Air Conditioning Condensing Unit 16 SEER, Two-Stage, Single-Phase, 2 Tons, R410A B61-603
Air Conditioning Condensing Unit 16 SEER, Two-Stage, Single-Phase, 2 Tons, R410A
SEER: 16; EER: 13.5; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 13.6; Max. Fuse Size: 20; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29-1/4"; Height: 32-1/2"; Depth: 29-1/4"; Wt. Lbs.: 180; OEM TXV: B18-099;
Brand: Goodman Mfg #: GSXC160241

Heat Pump 16 SEER, Single-Phase, 5 Ton, R410A B77-557
Heat Pump 16 SEER, Single-Phase, 5 Ton, R410A
SEER: 16; EER: 12.5; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 9.0; COP: 4.45; Min. Circuit Amps: 37.0; Max. Fuse Size: 60; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 35-1/2"; Height: 40";…
Brand: Goodman Mfg #: GSZ160601

Air Conditioning Condensing Unit 16 SEER, Single-Phase, 5 Ton, R410A B73-979
Air Conditioning Condensing Unit 16 SEER, Single-Phase, 5 Ton, R410A
SEER: 16; EER: 12.5; Nom. Tons: 5; BtuH Cooling: 54,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 29.6; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 38-1/4"; Depth: 35-1/2"; Wt. Lbs.: 279; OEM TXV: B18-727;
Brand: Goodman Mfg #: GSX160601

Air Conditioning Condensing Unit 16 SEER, Single-Phase, 3-1/2 Ton, R410A B73-977
Air Conditioning Condensing Unit 16 SEER, Single-Phase, 3-1/2 Ton, R410A
SEER: 16; EER: 12.2; Nom. Tons: 3-1/2; BtuH Cooling: 42,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 23.5; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 36-1/4"; Depth: 35-1/2"; Wt. Lbs.: 206; OEM TXV: B18-725;
Brand: Goodman Mfg #: GSX160421

Air Conditioning Condensing Unit 16 SEER, Two-Stage, Single-Phase, 5 Tons, R410A B61-606
Air Conditioning Condensing Unit 16 SEER, Two-Stage, Single-Phase, 5 Tons, R410A
SEER: 16; EER: 13.0; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 31.4; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 35-3/4"; Height: 42-1/4"; Depth: 35-3/4"; Wt. Lbs.: 304; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSXC160601

Air Conditioning Condensing Unit 16 SEER, Single-Phase, 3-1/2 Ton, R410A B60-823
Air Conditioning Condensing Unit 16 SEER, Single-Phase, 3-1/2 Ton, R410A
SEER: 16; EER: 13.0; Nom. Tons: 3-1/2; BtuH Cooling: 42,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 23.3; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 35-3/4"; Depth: 35-1/2"; Wt. Lbs.: 206; OEM TXV: B18-725;
Brand: Goodman Mfg #: GSX16S421

Air Conditioning Condensing Unit 16 SEER, Single-Phase, 2 Ton, R410A B60-820
Air Conditioning Condensing Unit 16 SEER, Single-Phase, 2 Ton, R410A
SEER: 16; EER: 13.0; Nom. Tons: 2; BtuH Cooling: 23,600; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 10.6; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29"; Height: 32"; Depth: 29"; Wt. Lbs.: 132; OEM TXV: B18-724;
Brand: Goodman Mfg #: GSX16S241

Single Packaged Heat Pump 16 SEER, Single-Phase, 2 Ton, R410A, Multi-Position B77-256
Single Packaged Heat Pump 16 SEER, Single-Phase, 2 Ton, R410A, Multi-Position
SEER: 16; EER: 12.5; Nom. Tons: 2; BtuH Cooling: 24,000; BtuH Heating Input: 22,800; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 3.6; Nom. CFM: 850; Min. Circuit Amps: 20.4; Refrigerant: R410A; Width: 47"; Height: 34-3/4"; Depth: 51"; Wt. Lbs.: 376;
Brand: Goodman Mfg #: GPH1624M41

Single Packaged Gas/Electric Air Conditioner 16 SEER, Single-Phase, 3-1/2 Ton, 81% AFUE, R410A, Multi-Position B75-675
Single Packaged Gas/Electric Air Conditioner 16 SEER, Single-Phase, 3-1/2 Ton, 81% AFUE, R410A, Multi-Position
SEER: 16; EER: 12.0; Nom. Tons: 3-1/2; BtuH Cooling: 40,000; BtuH Heating Input: 100,000; BtuH Heating Output: 78,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Nom. CFM: 1,250; Min. Circuit Amps: 29.2; Refrigerant: R410A; Width: 47"; Height: 42-3/4"; Depth: 51"; Wt. Lbs.: 495;
Brand: Goodman Mfg #: GPG1642100M41

Single Packaged Heat Pump 16 SEER, Single-Phase, 3-1/2 Ton, R410A, Multi-Position B77-259
Single Packaged Heat Pump 16 SEER, Single-Phase, 3-1/2 Ton, R410A, Multi-Position
SEER: 16; EER: 12.0; Nom. Tons: 3-1/2; BtuH Cooling: 41,000; BtuH Heating Input: 38,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.2; COP: 3.6; Nom. CFM: 1,300; Min. Circuit Amps: 29.6; Refrigerant: R410A; Width: 47"; Height: 42-1/4"; Depth: 51"; Wt. Lbs.: 492;
Brand: Goodman Mfg #: GPH1642M41

Single Packaged Heat Pump 16 SEER, Single-Phase, 3-1/2 Ton, R410A, Horizontal B76-934
Single Packaged Heat Pump 16 SEER, Single-Phase, 3-1/2 Ton, R410A, Horizontal
SEER: 16; EER: 12; Nom. Tons: 3-1/2; BtuH Cooling: 40,500; BtuH Heating Input: 37,600; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 3.8; Nom. CFM: 1,300; Min. Circuit Amps: 28.0; Refrigerant: R410A; Width: 66"; Height: 35"; Depth: 34"; Wt. Lbs.: 375;
Brand: Goodman Mfg #: GPH1642H41

Single Packaged Heat Pump 16 SEER, Single-Phase, 2 Ton, R410A, Horizontal B76-931
Single Packaged Heat Pump 16 SEER, Single-Phase, 2 Ton, R410A, Horizontal
SEER: 16; EER: 13; Nom. Tons: 2; BtuH Cooling: 24,000; BtuH Heating Input: 22,800; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 3.8; Nom. CFM: 875; Min. Circuit Amps: 21.0; Refrigerant: R410A; Width: 66"; Height: 30"; Depth: 34"; Wt. Lbs.: 315;
Brand: Goodman Mfg #: GPH1624H41

Single Packaged Heat Pump 16 SEER, Single-Phase, 5 Ton, R410A, Multi-Position B63-645
Single Packaged Heat Pump 16 SEER, Single-Phase, 5 Ton, R410A, Multi-Position
SEER: 16; EER: 12.0; Nom. Tons: 5; BtuH Cooling: 58,000; BtuH Heating Input: 58,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.2; COP: 3.7; Nom. CFM: 1,800; Min. Circuit Amps: 44.0; Refrigerant: R410A; Width: 48-49/250"; Height: 42-21/25"; Depth: 73-189/200"; Wt. Lbs.: 688;
Brand: Goodman Mfg #: GPH1660M41

Single Packaged Gas/Electric Air Conditioner 16 SEER, Single-Phase, 2 Ton, 81% AFUE, R410A, Multi-Position B75-672
Single Packaged Gas/Electric Air Conditioner 16 SEER, Single-Phase, 2 Ton, 81% AFUE, R410A, Multi-Position
SEER: 16; EER: 12.0; Nom. Tons: 2; BtuH Cooling: 22,800; BtuH Heating Input: 60,000; BtuH Heating Output: 47,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Nom. CFM: 800; Min. Circuit Amps: 19.5; Refrigerant: R410A; Width: 47"; Height: 34-3/4"; Depth: 51"; Wt. Lbs.: 370;
Brand: Goodman Mfg #: GPG1624060M41

Single Packaged Heat Pump 16 SEER, Single-Phase, 5 Ton, R410A, Horizontal B75-683
Single Packaged Heat Pump 16 SEER, Single-Phase, 5 Ton, R410A, Horizontal
SEER: 16; EER: 12; Nom. Tons: 5; BtuH Cooling: 57,500; BtuH Heating Input: 54,500; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.2; COP: 3.6; Nom. CFM: 1,700; Min. Circuit Amps: 40.0; Refrigerant: R410A; Width: 66"; Height: 38-3/4"; Depth: 34"; Wt. Lbs.: 405;
Brand: Goodman Mfg #: GPH1660H41

Single Packaged Gas/Electric Air Conditioner 16 SEER, Single-Phase, 5 Ton, 81% AFUE, R410A, Multi-Position B63-644
Single Packaged Gas/Electric Air Conditioner 16 SEER, Single-Phase, 5 Ton, 81% AFUE, R410A, Multi-Position
SEER: 16; EER: 12.0; Nom. Tons: 5; BtuH Cooling: 58,000; BtuH Heating Input: 138,000; BtuH Heating Output: 112,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Nom. CFM: 2,000; Min. Circuit Amps: 43.4; Refrigerant: R410A; Width: 48-49/250"; Height: 42-21/25"; Depth: 73-189/200"; Wt. Lbs.: 655;
Brand: Goodman Mfg #: GPG1660140M41

Heat Pump 16 SEER, Two-Stage, Single-Phase, 5 Tons, R410A B91-227
Heat Pump 16 SEER, Two-Stage, Single-Phase, 5 Tons, R410A
SEER: 16; EER: 12.5; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.35; COP: 4.45; Min. Circuit Amps: 37.2; Max. Fuse Size: 60; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 35-1/2"; Height:…
Brand: Goodman Mfg #: DSZC160601

Heat Pump 16 SEER, Two-Stage, Single-Phase, 2 Tons, R410A B91-224
Heat Pump 16 SEER, Two-Stage, Single-Phase, 2 Tons, R410A
SEER: 16; EER: 12.5; Nom. Tons: 2; BtuH Cooling: 24,000; BtuH Heating Input: 24,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.5; COP: 4.74; Min. Circuit Amps: 15.8; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29"; Height: 38-1/4"; Depth:…
Brand: Goodman Mfg #: DSZC160241

Air Conditioning Condensing Unit 16 SEER, Two-Stage, Single-Phase, 2 Tons, R410A B91-217
Air Conditioning Condensing Unit 16 SEER, Two-Stage, Single-Phase, 2 Tons, R410A
SEER: 16; EER: 13.0; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 15.7; Max. Fuse Size: 20; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29"; Height: 32-1/4"; Depth: 29"; Wt. Lbs.: 181; OEM TXV: B18-099;
Brand: Goodman Mfg #: DSXC160241
FTL Finance