214 Results

5, 4, Coleman, Residential Unitary, HVAC Equipment

Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 5 Ton, R410 , 81% AFUE B76-980
Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 5 Ton, R410 , 81% AFUE
SEER: 14; Nom. Tons: 5; BtuH Cooling: 52,500; BtuH Heating Input: 100,000; BtuH Heating Output: 80,000; Volts: 208/230V; Phase: Single; Nom. CFM: 2,000; Min. Circuit Amps: 42.6; Refrigerant: R410A; Width: 45-3/4"; Height: 51"; Depth: 51"; Wt. Lbs.: 60;
Brand: Coleman Mfg #: PCG4B601002X2

Single Packaged Gas/Heat Air Conditioner LX Series, 14 SEER, Single-Phase, 4 Ton, R410A, 81% AFUE B61-587
Single Packaged Gas/Heat Air Conditioner LX Series, 14 SEER, Single-Phase, 4 Ton, R410A, 81% AFUE
SEER: 14; EER: 11.2; Nom. Tons: 4; BtuH Cooling: 45,500; BtuH Heating Input: 100,000; BtuH Heating Output: 80,000; Volts: 208/230V; Phase: Single; Nom. CFM: 1,600; Min. Circuit Amps: 34.4; Refrigerant: R410A; Width: 45-3/4"; Height: 49"; Depth: 51"; Wt. Lbs.: 473;
Brand: Coleman Mfg #: PCG4B481252X2

Packaged Heat Pump 16 SEER, Single-Phase, Single-Stage, 5 Ton, R410A B60-889
Packaged Heat Pump 16 SEER, Single-Phase, Single-Stage, 5 Ton, R410A
SEER: 16; EER: 12.5; Nom. Tons: 5; BtuH Cooling: 57,500; BtuH Heating Input: 125,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.2; COP: 3.6; Nom. CFM: 1,800; Min. Circuit Amps: 44.7; Refrigerant: R410A; Width: 45-3/4"; Height: 55"; Depth: 51-1/4"; Wt. Lbs.: 588;
Brand: Coleman Mfg #: PHG6B601252X1

Dual Fuel Packaged Heat Pump 16 SEER, Single-Phase, Single-Stage, 4 Ton, R410A B60-884
Dual Fuel Packaged Heat Pump 16 SEER, Single-Phase, Single-Stage, 4 Ton, R410A
SEER: 16; EER: 12.5; Nom. Tons: 4; BtuH Cooling: 47,500; BtuH Heating Input: 65,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.2; COP: 3.6; Nom. CFM: 1,600; Min. Circuit Amps: 33.6; Refrigerant: R410A; Width: 45-3/4"; Height: 53"; Depth: 51-1/4"; Wt. Lbs.: 551;
Brand: Coleman Mfg #: PHG6B480652X1

Dual Fuel Packaged Heat Pump 16 SEER, Single-Phase, Single-Stage, 5 Ton, R410A B60-888
Dual Fuel Packaged Heat Pump 16 SEER, Single-Phase, Single-Stage, 5 Ton, R410A
SEER: 16; EER: 12.5; Nom. Tons: 5; BtuH Cooling: 57,500; BtuH Heating Input: 100,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.2; COP: 3.6; Nom. CFM: 1,800; Min. Circuit Amps: 44.7; Refrigerant: R410A; Width: 45-3/4"; Height: 55"; Depth: 51-1/4"; Wt. Lbs.: 581;
Brand: Coleman Mfg #: PHG6B601002X1

Dual Fuel Packaged Heat Pump 16 SEER, Single-Phase, Single-Stage, 4 Ton, R410A B60-886
Dual Fuel Packaged Heat Pump 16 SEER, Single-Phase, Single-Stage, 4 Ton, R410A
SEER: 16; EER: 12.5; Nom. Tons: 4; BtuH Cooling: 47,500; BtuH Heating Input: 125,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.2; COP: 3.6; Nom. CFM: 1,600; Min. Circuit Amps: 33.6; Refrigerant: R410A; Width: 45-3/4"; Height: 53"; Depth: 51-1/4"; Wt. Lbs.: 564;
Brand: Coleman Mfg #: PHG6B481252X1

Evaporator Coil Full Cased, Upflow-Downflow B65-434
Evaporator Coil Full Cased, Upflow-Downflow
Nom. Tons: 5; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Width: 21"; Height: 28"; Depth: 21-1/2"; Wt. Lbs.: 75; Description: Cased; Configuration: Upflow / Downflow; Metering Device: Flowrater; Coil Type: Cased; TXV Included: No;
Brand: Coleman Mfg #: CC60A3G-210L-025

Evaporator Coil Full Cased, Upflow-Downflow B65-433
Evaporator Coil Full Cased, Upflow-Downflow
Nom. Tons: 4; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Width: 21"; Height: 24"; Depth: 21-1/2"; Wt. Lbs.: 62; Description: Cased; Configuration: Upflow / Downflow; Metering Device: Flowrater; Coil Type: Cased; TXV Included: No;
Brand: Coleman Mfg #: CC48A3G-210L-025

Evaporator Coil Full Cased, Upflow-Downflow B65-436
Evaporator Coil Full Cased, Upflow-Downflow
Nom. Tons: 5; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Width: 24-1/2"; Height: 28"; Depth: 21-1/2"; Wt. Lbs.: 81; Description: Cased; Configuration: Upflow / Downflow; Metering Device: Flowrater; Coil Type: Cased; TXV Included: No;
Brand: Coleman Mfg #: CC60B3G-245L-025

Evaporator Coil Full Cased, Upflow-Downflow B65-435
Evaporator Coil Full Cased, Upflow-Downflow
Nom. Tons: 5; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Width: 24-1/2"; Height: 28"; Depth: 21-1/2"; Wt. Lbs.: 75; Description: Cased; Configuration: Upflow / Downflow; Metering Device: Flowrater; Coil Type: Cased; TXV Included: No;
Brand: Coleman Mfg #: CC60A3G-245L-025

Evaporator Coil Full Cased, Multi-Position B65-442
Evaporator Coil Full Cased, Multi-Position
Nom. Tons: 5; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Width: 24-1/2"; Height: 30"; Depth: 21-1/2"; Wt. Lbs.: 78; Description: Cased; Configuration: Multi-Position; Metering Device: TXV; Coil Type: Cased; TXV Included: Yes;
Brand: Coleman Mfg #: CE60A36-245L-142

Single Packaged Gas/Heat Air Conditioner LX Series, 16 SEER, Single-Phase, 5 Ton, R410 , 81% AFUE B79-053
Single Packaged Gas/Heat Air Conditioner LX Series, 16 SEER, Single-Phase, 5 Ton, R410 , 81% AFUE
SEER: 16; Nom. Tons: 5; BtuH Cooling: 58,000; BtuH Heating Input: 100,000; BtuH Heating Output: 80,000; Volts: 208/230; Phase: Single; Nom. CFM: 2,000; Min. Circuit Amps: 42.3; Refrigerant: R410A; Width: 45-3/4; Height: 55"; Depth: 51-1/4"; Wt. Lbs.: 541;
Brand: Coleman Mfg #: PCG6B601002X1

Single Packaged Gas/Heat Air Conditioner LX Series, 16 SEER, Single-Phase, 4 Ton, R410A, 81% AFUE B79-051
Single Packaged Gas/Heat Air Conditioner LX Series, 16 SEER, Single-Phase, 4 Ton, R410A, 81% AFUE
SEER: 16; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 125,000; BtuH Heating Output: 101,000; Volts: 208/230; Phase: Single; Nom. CFM: 1,600; Min. Circuit Amps: 33.6; Refrigerant: R410A; Width: 45-3/4; Height: 53"; Depth: 51-1/4"; Wt. Lbs.: 533;
Brand: Coleman Mfg #: PCG6B481252X1

Single Packaged Gas/Heat Air Conditioner LX Series, 16 SEER, Single-Phase, 4 Ton, R410A, 81% AFUE B79-049
Single Packaged Gas/Heat Air Conditioner LX Series, 16 SEER, Single-Phase, 4 Ton, R410A, 81% AFUE
SEER: 16; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 65,000; BtuH Heating Output: 52,000; Volts: 208/230; Phase: Single; Nom. CFM: 1,600; Min. Circuit Amps: 33.6; Refrigerant: R410A; Width: 45-3/4; Height: 53"; Depth: 51-1/4"; Wt. Lbs.: 520;
Brand: Coleman Mfg #: PCG6B480652X1

Dual Fuel Packaged Heat Pump 14 SEER, Single-Phase, Single-Stage, 4 Ton, R410A B77-294
Dual Fuel Packaged Heat Pump 14 SEER, Single-Phase, Single-Stage, 4 Ton, R410A
SEER: 14; EER: 11; Nom. Tons: 4; BtuH Cooling: 45,500; BtuH Heating Input: 125,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 3.5; Nom. CFM: 1,600; Min. Circuit Amps: 34.6; Refrigerant: R410A; Width: 45-3/4"; Height: 53"; Depth: 51-1/4"; Wt. Lbs.: 564;
Brand: Coleman Mfg #: PHG4B481252X1

Dual Fuel Packaged Heat Pump 14 SEER, Single-Phase, Single-Stage, 5 Ton, R410A B77-295
Dual Fuel Packaged Heat Pump 14 SEER, Single-Phase, Single-Stage, 5 Ton, R410A
SEER: 14; EER: 11; Nom. Tons: 5; BtuH Cooling: 57,500; BtuH Heating Input: 65,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 4.3; Nom. CFM: 2,000; Min. Circuit Amps: 38.7; Refrigerant: R410A; Width: 45-3/4"; Height: 55"; Depth: 51-1/4"; Wt. Lbs.: 577;
Brand: Coleman Mfg #: PHG4B600652X1

Dual Fuel Packaged Heat Pump 14 SEER, Single-Phase, Single-Stage, 4 Ton, R410A B77-292
Dual Fuel Packaged Heat Pump 14 SEER, Single-Phase, Single-Stage, 4 Ton, R410A
SEER: 14; EER: 11; Nom. Tons: 4; BtuH Cooling: 45,500; BtuH Heating Input: 65,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 3.5; Nom. CFM: 1,600; Min. Circuit Amps: 34.6; Refrigerant: R410A; Width: 45-3/4"; Height: 53"; Depth: 51-1/4"; Wt. Lbs.: 551;
Brand: Coleman Mfg #: PHG4B480652X1

Dual Fuel Packaged Heat Pump 14 SEER, Single-Phase, Single-Stage, 4 Ton, R410A B77-293
Dual Fuel Packaged Heat Pump 14 SEER, Single-Phase, Single-Stage, 4 Ton, R410A
SEER: 14; EER: 11; Nom. Tons: 4; BtuH Cooling: 45,500; BtuH Heating Input: 100,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 3.5; Nom. CFM: 1,600; Min. Circuit Amps: 34.6; Refrigerant: R410A; Width: 45-3/4"; Height: 53"; Depth: 51-1/4"; Wt. Lbs.: 559;
Brand: Coleman Mfg #: PHG4B481002X1

Dual Fuel Packaged Heat Pump 14 SEER, Single-Phase, Single-Stage, 5 Ton, R410A B77-296
Dual Fuel Packaged Heat Pump 14 SEER, Single-Phase, Single-Stage, 5 Ton, R410A
SEER: 14; EER: 11; Nom. Tons: 5; BtuH Cooling: 57,500; BtuH Heating Input: 100,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 4.3; Nom. CFM: 2,000; Min. Circuit Amps: 38.7; Refrigerant: R410A; Width: 45-3/4"; Height: 55"; Depth: 51-1/4"; Wt. Lbs.: 581;
Brand: Coleman Mfg #: PHG4B601002X1

Single Packaged Air Conditioner 16 SEER, Single-Phase, 4 Ton, R410A B79-393
Single Packaged Air Conditioner 16 SEER, Single-Phase, 4 Ton, R410A
SEER: 16; EER: 12.5; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Nom. CFM: 1,600; Min. Circuit Amps: 33.6; Max. Fuse Size: 50; Refrigerant: R410A; Width: 45-3/4"; Height: 53"; Depth: 51-1/4"; Wt. Lbs.: 483;
Brand: Coleman Mfg #: PCE6B4821

Single Packaged Air Conditioner 16 SEER, Single-Phase, 5 Ton, R410A B79-394
Single Packaged Air Conditioner 16 SEER, Single-Phase, 5 Ton, R410A
SEER: 16; EER: 12.0; Nom. Tons: 5; BtuH Cooling: 58,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Nom. CFM: 2,000; Min. Circuit Amps: 42.3; Max. Fuse Size: 60; Refrigerant: R410A; Width: 45-3/4"; Height: 55"; Depth: 51-1/4"; Wt. Lbs.: 500;
Brand: Coleman Mfg #: PCE6B6021

Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 4 Ton, R410A, 81% AFUE B76-978
Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 4 Ton, R410A, 81% AFUE
SEER: 14; Nom. Tons: 4; BtuH Cooling: 45,500; BtuH Heating Input: 125,000; BtuH Heating Output: 100,000; Nom. CFM: 1,600; Min. Circuit Amps: 34.7; Refrigerant: R410A; Width: 45-3/4"; Height: 49"; Depth: 51"; Wt. Lbs.: 533;
Brand: Coleman Mfg #: PCG4B481252X1
FTL Finance
Powered by Site Search powered by SLI Systems
Select products to compare.
Compare