188 Results

5, 4, Split Systems, Residential Unitary, HVAC Equipment

Air Conditioning Condensing Unit 18 SEER, Two-Stage, Single-Phase, 4 Tons, R410A B61-601
Air Conditioning Condensing Unit 18 SEER, Two-Stage, Single-Phase, 4 Tons, R410A
SEER: 18; EER: 13.5; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 28.3; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 35-3/4"; Height: 42-1/4"; Depth: 35-3/4"; Wt. Lbs.: 298; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSXC180481

Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 4 Ton, R410A, Southwest Region Only B77-437
Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 4 Ton, R410A, Southwest Region Only
SEER: 14; EER: 11.7; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 25.7; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/4"; Height: 33-1/4"; Depth: 31-3/4"; Wt. Lbs.: 200; OEM TXV: B19-659; OEM…
Brand: Coleman Mfg #: TW4B4821S

Air Conditioning Condensing Unit 16 SEER, Two-Stage, Single-Phase, 4 Tons, R410A B61-605
Air Conditioning Condensing Unit 16 SEER, Two-Stage, Single-Phase, 4 Tons, R410A
SEER: 16; EER: 13.0; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 26.7; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 35-3/4"; Height: 37"; Depth: 35-3/4"; Wt. Lbs.: 263; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSXC160481

Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 5 Ton, R410A B77-536
Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 5 Ton, R410A
SEER: 14; EER: 12; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 31.7; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 38"; Height: 36-1/4"; Depth: 38"; Wt. Lbs.: 220; OEM TXV: B19-660; OEM TXV for…
Brand: Evcon Mfg #: RAC14L60B23S

Air Conditioning Condensing Unit 16 SEER, Two-Stage, Single-Phase, 5 Tons, R410A B61-606
Air Conditioning Condensing Unit 16 SEER, Two-Stage, Single-Phase, 5 Tons, R410A
SEER: 16; EER: 13.0; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 31.4; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 35-3/4"; Height: 42-1/4"; Depth: 35-3/4"; Wt. Lbs.: 304; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSXC160601

Heat Pump LX Series, 14 SEER, Single-Phase, 4 Ton, R410A B62-886
Heat Pump LX Series, 14 SEER, Single-Phase, 4 Ton, R410A
SEER: 14; EER: 12.0; Nom. Tons: 4; BtuH Cooling: 46,500; BtuH Heating Input: 45,500; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 9.0; COP: 3.58; Min. Circuit Amps: 24.5; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 38"; Height: 39-1/2"; Depth:…
Brand: Evcon Mfg #: REP14L48B21S

Heat Pump LX Series, 14 SEER, Single-Phase, 5 Ton, R410A B62-887
Heat Pump LX Series, 14 SEER, Single-Phase, 5 Ton, R410A
SEER: 14; EER: 12.0; Nom. Tons: 5; BtuH Cooling: 56,500; BtuH Heating Input: 56,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 9.0; COP: 3.70; Min. Circuit Amps: 29.1; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 38"; Height: 42-3/4";…
Brand: Evcon Mfg #: REP14L60B21S

Air Conditioning Condensing Unit Horizontal Discharge, 14 SEER, Single-Phase, 4 Ton, R410A B60-176
Air Conditioning Condensing Unit Horizontal Discharge, 14 SEER, Single-Phase, 4 Ton, R410A
SEER: 14; EER: 12.2; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 24.6; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 45"; Height: 43-1/4"; Depth: 20"; Wt. Lbs.: 240; OEM TXV: B20-259; OEM TXV for…
Brand: Coleman Mfg #: TCHE48S41S1

Air Conditioning Condensing Unit GMC Series, 13 SEER, Single-Phase, 4 Ton, R410A B91-675
Air Conditioning Condensing Unit GMC Series, 13 SEER, Single-Phase, 4 Ton, R410A
SEER: 13; EER: 11.0; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 26.4; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 29"; Height: 36-1/4"; Depth: 29"; Wt. Lbs.: 175; OEM TXV: B14-851;
Brand: Goodman Mfg #: VSX130481

Air Conditioning Condensing Unit GMC Series, 13 SEER, Single-Phase, 5 Ton, R410A B91-676
Air Conditioning Condensing Unit GMC Series, 13 SEER, Single-Phase, 5 Ton, R410A
SEER: 13; EER: 11.0; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 32.8; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 29"; Height: 40"; Depth: 29"; Wt. Lbs.: 184; OEM TXV: B14-851;
Brand: Goodman Mfg #: VSX130601

Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 5 Ton, R410A, Southwest Region Only B77-438
Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 5 Ton, R410A, Southwest Region Only
SEER: 14; EER: 11.7; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 31.7; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 38"; Height: 36-1/4"; Depth: 31-3/4"; Wt. Lbs.: 205; OEM TXV: B19-660; OEM…
Brand: Coleman Mfg #: TW4B6021S

Heat Pump 20 SEER, Variable-Speed, Inverter Drive, Single-Phase, 5 Ton, R410A B64-187
Heat Pump 20 SEER, Variable-Speed, Inverter Drive, Single-Phase, 5 Ton, R410A
SEER: 20; Nom. Tons: 5; BtuH Cooling: 52,500; BtuH Heating Input: 52,000; Volts: 208/230; Phase: Single; Motor Type: Variable-Speed; COP: 3.68; Min. Circuit Amps: 30.6; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 41-1/4"; Depth:…
Brand: Goodman Mfg #: GVZC200601

Heat Pump 20 SEER, Variable-Speed, Inverter Drive, Single-Phase, 4 Ton, R410A B64-186
Heat Pump 20 SEER, Variable-Speed, Inverter Drive, Single-Phase, 4 Ton, R410A
SEER: 20; Nom. Tons: 4; BtuH Cooling: 46,500; BtuH Heating Input: 46,000; Volts: 208/230; Phase: Single; Motor Type: Variable-Speed; COP: 3.72; Min. Circuit Amps: 29.8; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 41-1/4"; Depth:…
Brand: Goodman Mfg #: GVZC200481

Air Conditioning Condensing Unit Horizontal Discharge, 13 SEER, Single-Phase, 5 Ton, R410A B91-944
Air Conditioning Condensing Unit Horizontal Discharge, 13 SEER, Single-Phase, 5 Ton, R410A
SEER: 13; EER: 11.75; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 34.3; Max. Fuse Size: 60; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 45"; Height: 43-1/4"; Depth: 20"; Wt. Lbs.: 250; OEM TXV: B19-660; OEM TXV for…
Brand: Coleman Mfg #: TCHD60S41S3

Air Conditioning Condensing Unit RAC134 Series, 13.4 SEER2, Single-Phase, 5 Ton, R410A B66-469
Air Conditioning Condensing Unit RAC134 Series, 13.4 SEER2, Single-Phase, 5 Ton, R410A
SEER2: 13.4; EER2: 11.0; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 29.1; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 34-1/4"; Height: 36-1/4"; Depth: 34-1/4"; Wt. Lbs.: 230; OEM TXV:…
Brand: Evcon Mfg #: RAC13460B21S

Heat Pump 14 SEER, Single-Phase, 4 Ton, R410A B75-677
Heat Pump 14 SEER, Single-Phase, 4 Ton, R410A
SEER: 14; EER: 11.5; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 48,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.5; COP: 4.39; Min. Circuit Amps: 26; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 34-1/2";…
Brand: Goodman Mfg #: GSZ140491

Air Conditioning Condensing Unit ASXH5 Series, 15.2SEER2 4T Single-Phase, R410A B65-691
Air Conditioning Condensing Unit ASXH5 Series, 15.2SEER2 4T Single-Phase, R410A
SEER2: 15.2; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 26.2; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 36-1/2"; Depth: 35-1/2"; Wt. Lbs.: 260; OEM TXV: B14-851;
Brand: Amana Mfg #: ASXH504810

Air Conditioning Condensing Unit 20 SEER, Variable-Speed, Inverter Drive, Single-Phase, 4 Ton, R410A B64-182
Air Conditioning Condensing Unit 20 SEER, Variable-Speed, Inverter Drive, Single-Phase, 4 Ton, R410A
SEER: 20; Nom. Tons: 4; BtuH Cooling: 45,500; Volts: 208/230; Phase: Single; Motor Type: Variable-Speed; Min. Circuit Amps: 30.1; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 41-3/4"; Depth: 35-1/2"; Wt. Lbs.: 321; OEM TXV: B18-928;
Brand: Goodman Mfg #: GVXC200481

Air Conditioning Condensing Unit Horizontal Discharge, 13 SEER, Single-Phase, 4 Ton, R410A B91-943
Air Conditioning Condensing Unit Horizontal Discharge, 13 SEER, Single-Phase, 4 Ton, R410A
SEER: 13; EER: 12.25; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 27.1; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 45"; Height: 43-1/4"; Depth: 20"; Wt. Lbs.: 240; OEM TXV: B19-659; OEM TXV for…
Brand: Coleman Mfg #: TCHD48S41S3

Air Conditioning Condensing Unit 20 SEER, Variable-Speed, Inverter Drive, Single-Phase, 5 Ton, R410A B64-183
Air Conditioning Condensing Unit 20 SEER, Variable-Speed, Inverter Drive, Single-Phase, 5 Ton, R410A
SEER: 20; Nom. Tons: 5; BtuH Cooling: 53,000; Volts: 208/230; Phase: Single; Motor Type: Variable-Speed; Min. Circuit Amps: 31.1; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 41-3/4"; Depth: 35-1/2"; Wt. Lbs.: 321; OEM TXV: B18-929;
Brand: Goodman Mfg #: GVXC200601

Side Discharge Air Conditioning Condensing Unit 16.2 SEER2, Single-Phase, Variable-Speed, 4 Ton, R410A B66-620
Side Discharge Air Conditioning Condensing Unit 16.2 SEER2, Single-Phase, Variable-Speed, 4 Ton, R410A
SEER2: 16.2; Nom. Tons: 4; BtuH Cooling: 45,000; Volts: 208/230; Phase: Single; Min. Circuit Amps: 34.4; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 37"; Height: 39"; Depth: 12-5/8"; Wt. Lbs.: 163;
Brand: Amana Mfg #: ASXS6S4810

Side Discharge Air Conditioning Condensing Unit 16.2 SEER2, Single-Phase, Variable-Speed, 5 Ton, R410A B66-621
Side Discharge Air Conditioning Condensing Unit 16.2 SEER2, Single-Phase, Variable-Speed, 5 Ton, R410A
SEER2: 16.2; Nom. Tons: 5; BtuH Cooling: 53,000; Volts: 208/230; Phase: Single; Min. Circuit Amps: 36.2; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 37"; Height: 39"; Depth: 12-5/8"; Wt. Lbs.: 174;
Brand: Amana Mfg #: ASXS6S6010

Inverter Drive Side Discharge Heat Pump 16.2 SEER2, Single-Phase, 4 Ton, Variable-Speed B66-627
Inverter Drive Side Discharge Heat Pump 16.2 SEER2, Single-Phase, 4 Ton, Variable-Speed
SEER2: 16.2; Nom. Tons: 4; BtuH Cooling: 45,000; BtuH Heating Input: 45,500; Volts: 208/230; Phase: Single; HSPF2: 8.5; COP: 3.0; Min. Circuit Amps: 34.4; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 36-5/8"; Height: 27-3/8"; Depth: 13-3/4"; Wt. Lbs.: 168;
Brand: Amana Mfg #: ASZS604810

Air Conditioning Condensing Unit ASXH5 Series, 15.2SEER2 5T Single-Phase, R410A B65-692
Air Conditioning Condensing Unit ASXH5 Series, 15.2SEER2 5T Single-Phase, R410A
SEER2: 15.2; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 32.4; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 41-5/8"; Depth: 35-1/2"; Wt. Lbs.: 283; OEM TXV: B14-851;
Brand: Amana Mfg #: ASXH506010
FTL Finance
Powered by Site Search powered by SLI Systems
Select products to compare.