62 Results

16, 5, 3, 12 to 12.8, HVAC Equipment

Packaged Heat Pump 16 SEER, Single-Phase, Single-Stage, 5 Ton, R410A B60-889
Packaged Heat Pump 16 SEER, Single-Phase, Single-Stage, 5 Ton, R410A
SEER: 16; EER: 12.5; Nom. Tons: 5; BtuH Cooling: 57,500; BtuH Heating Input: 125,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.2; COP: 3.6; Nom. CFM: 1,800; Min. Circuit Amps: 44.7; Refrigerant: R410A; Width: 45-3/4"; Height: 55"; Depth: 51-1/4"; Wt. Lbs.: 588;
Brand: Coleman Mfg #: PHG6B601252X1

Packaged Heat Pump 16 SEER, Single-Phase, Single-Stage, 3 Ton, R410A B60-881
Packaged Heat Pump 16 SEER, Single-Phase, Single-Stage, 3 Ton, R410A
SEER: 16; EER: 12.5; Nom. Tons: 3; BtuH Cooling: 36,400; BtuH Heating Input: 100,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.2; COP: 3.6; Nom. CFM: 1,200; Min. Circuit Amps: 26.2; Refrigerant: R410A; Width: 45-3/4"; Height: 49"; Depth: 51-1/4"; Wt. Lbs.: 505;
Brand: Coleman Mfg #: PHG6B361002X1

Dual Fuel Packaged Heat Pump 16 SEER, Single-Phase, Single-Stage, 5 Ton, R410A B60-888
Dual Fuel Packaged Heat Pump 16 SEER, Single-Phase, Single-Stage, 5 Ton, R410A
SEER: 16; EER: 12.5; Nom. Tons: 5; BtuH Cooling: 57,500; BtuH Heating Input: 100,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.2; COP: 3.6; Nom. CFM: 1,800; Min. Circuit Amps: 44.7; Refrigerant: R410A; Width: 45-3/4"; Height: 55"; Depth: 51-1/4"; Wt. Lbs.: 581;
Brand: Coleman Mfg #: PHG6B601002X1

Dual Fuel Packaged Heat Pump 16 SEER, Single-Phase, Single-Stage, 3 Ton, R410A B60-880
Dual Fuel Packaged Heat Pump 16 SEER, Single-Phase, Single-Stage, 3 Ton, R410A
SEER: 16; EER: 12.5; Nom. Tons: 3; BtuH Cooling: 36,400; BtuH Heating Input: 65,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.2; COP: 3.6; Nom. CFM: 1,200; Min. Circuit Amps: 24.6; Refrigerant: R410A; Width: 45-3/4"; Height: 49"; Depth: 51-1/4"; Wt. Lbs.: 498;
Brand: Coleman Mfg #: PHG6B360652X1

Single Packaged Heat Pump 16 SEER, Single-Phase, 5 Ton, R410A, Multi-Position B63-647
Single Packaged Heat Pump 16 SEER, Single-Phase, 5 Ton, R410A, Multi-Position
SEER: 16; EER: 12.0; Nom. Tons: 5; BtuH Cooling: 58,000; BtuH Heating Input: 58,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.2; COP: 3.7; Nom. CFM: 1800; Min. Circuit Amps: 44.0; Refrigerant: R410A; Width: 48-49/250"; Height: 42-21/25"; Depth: 73-189/200"; Wt. Lbs.: 688;
Brand: Amana Mfg #: APH1660M41

Single Packaged Heat Pump 16 SEER, Single-Phase, 3 Ton, R410A, Multi-Position B77-263
Single Packaged Heat Pump 16 SEER, Single-Phase, 3 Ton, R410A, Multi-Position
SEER: 16; EER: 12.0; Nom. Tons: 3; BtuH Cooling: 33,600; BtuH Heating Input: 33,600; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 3.6; Nom. CFM: 1,200; Min. Circuit Amps: 24.9; Refrigerant: R410A; Width: 47"; Height: 34-3/4"; Depth: 51"; Wt. Lbs.: 438;
Brand: Amana Mfg #: APH1636M41

Single Packaged Air Conditioner 16 SEER, Three-Phase, 5 Ton, R410A B79-941
Single Packaged Air Conditioner 16 SEER, Three-Phase, 5 Ton, R410A
SEER: 16; EER: 12.0; Nom. Tons: 5; BtuH Cooling: 58,000; Volts: 460; Phase: Three; Motor Type: ECM; Nom. CFM: 2,000; Min. Circuit Amps: 34.5; Max. Fuse Size: 35; Refrigerant: R410A; Width: 45-3/4"; Height: 55"; Depth: 51-1/4"; Wt. Lbs.: 500;
Brand: Coleman Mfg #: PCE6B6041

Single Packaged Air Conditioner 16 SEER, Three-Phase, 3 Ton, R410A B79-939
Single Packaged Air Conditioner 16 SEER, Three-Phase, 3 Ton, R410A
SEER: 16; EER: 12.5; Nom. Tons: 3; BtuH Cooling: 36,000; Volts: 460; Phase: Three; Motor Type: ECM; Nom. CFM: 1,200; Min. Circuit Amps: 20.7; Max. Fuse Size: 25; Refrigerant: R410A; Width: 45-3/4"; Height: 49"; Depth: 51-1/4"; Wt. Lbs.: 460;
Brand: Coleman Mfg #: PCE6B3641

Single Packaged Gas/Heat Air Conditioner 16 SEER, Three-Phase, 5 Ton, R410A, 81% AFUE B79-935
Single Packaged Gas/Heat Air Conditioner 16 SEER, Three-Phase, 5 Ton, R410A, 81% AFUE
SEER: 16; EER: 12.0; Nom. Tons: 5; BtuH Cooling: 58,000; BtuH Heating Input: 125,000; BtuH Heating Output: 101,000; Volts: 460; Phase: Three; Motor Type: ECM; Nom. CFM: 2,000; Min. Circuit Amps: 13.7; Refrigerant: R410A; Width: 45-3/4"; Height: 55"; Depth: 51-1/4"; Wt. Lbs.: 543;
Brand: Coleman Mfg #: PCG6B601254X1

Single Packaged Gas/Heat Air Conditioner 16 SEER, Three-Phase, 5 Ton, R410A, 81% AFUE B79-933
Single Packaged Gas/Heat Air Conditioner 16 SEER, Three-Phase, 5 Ton, R410A, 81% AFUE
SEER: 16; EER: 12.0; Nom. Tons: 5; BtuH Cooling: 58,000; BtuH Heating Input: 65,000; BtuH Heating Output: 52,000; Volts: 460; Phase: Three; Motor Type: ECM; Nom. CFM: 2,000; Min. Circuit Amps: 13.7; Refrigerant: R410A; Width: 45-3/4"; Height: 55"; Depth: 51-1/4"; Wt. Lbs.: 532;
Brand: Coleman Mfg #: PCG6B600654X1

Single Packaged Gas/Heat Air Conditioner 16 SEER, Three-Phase, 5 Ton, R410A, 81% AFUE B79-934
Single Packaged Gas/Heat Air Conditioner 16 SEER, Three-Phase, 5 Ton, R410A, 81% AFUE
SEER: 16; EER: 12.0; Nom. Tons: 5; BtuH Cooling: 58,000; BtuH Heating Input: 100,000; BtuH Heating Output: 81,000; Volts: 460; Phase: Three; Motor Type: ECM; Nom. CFM: 2,000; Min. Circuit Amps: 13.7; Refrigerant: R410A; Width: 45-3/4"; Height: 55"; Depth: 51-1/4"; Wt. Lbs.: 536;
Brand: Coleman Mfg #: PCG6B601004X1

Single Packaged Gas/Heat Air Conditioner 16 SEER, Three-Phase, 3 Ton, R410A, 81% AFUE B79-926
Single Packaged Gas/Heat Air Conditioner 16 SEER, Three-Phase, 3 Ton, R410A, 81% AFUE
SEER: 16; EER: 12.5; Nom. Tons: 3; BtuH Cooling: 36,000; BtuH Heating Input: 65,000; BtuH Heating Output: 52,000; Volts: 460; Phase: Three; Motor Type: ECM; Nom. CFM: 1,200; Min. Circuit Amps: 9.9; Refrigerant: R410A; Width: 45-3/4"; Height: 49"; Depth: 51-1/4"; Wt. Lbs.: 461;
Brand: Coleman Mfg #: PCG6B360654X1

Single Packaged Gas/Heat Air Conditioner 16 SEER, Three-Phase, 3 Ton, R410A, 81% AFUE B79-927
Single Packaged Gas/Heat Air Conditioner 16 SEER, Three-Phase, 3 Ton, R410A, 81% AFUE
SEER: 16; EER: 12.5; Nom. Tons: 3; BtuH Cooling: 36,000; BtuH Heating Input: 100,000; BtuH Heating Output: 81,000; Volts: 460; Phase: Three; Motor Type: ECM; Nom. CFM: 1,200; Min. Circuit Amps: 9.9; Refrigerant: R410A; Width: 45-3/4"; Height: 49"; Depth: 51-1/4"; Wt. Lbs.: 468;
Brand: Coleman Mfg #: PCG6B361004X1

Single Packaged Air Conditioner 16 SEER, Single-Phase, 5 Ton, R410A B79-394
Single Packaged Air Conditioner 16 SEER, Single-Phase, 5 Ton, R410A
SEER: 16; EER: 12.0; Nom. Tons: 5; BtuH Cooling: 58,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Nom. CFM: 2,000; Min. Circuit Amps: 42.3; Max. Fuse Size: 60; Refrigerant: R410A; Width: 45-3/4"; Height: 55"; Depth: 51-1/4"; Wt. Lbs.: 500;
Brand: Coleman Mfg #: PCE6B6021
FTL Finance
Powered by Site Search powered by SLI Systems
Select products to compare.
Compare