81 Results

16, 5, 3, HVAC Equipment

Single Packaged Gas/Heat Air Conditioner LX Series, 16 SEER, Single-Phase, 3 Ton, R410A, 81% AFUE B64-226
Single Packaged Gas/Heat Air Conditioner LX Series, 16 SEER, Single-Phase, 3 Ton, R410A, 81% AFUE
SEER: 16; EER: 12.0; Nom. Tons: 3; BtuH Cooling: 35,800; BtuH Heating Input: 75,000; BtuH Heating Output: 60,000; Volts: 208/230; Phase: Single; Nom. CFM: 1,200; Min. Circuit Amps: 23.2; Refrigerant: R410A; Width: 35-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 466;
Brand: Coleman Mfg #: PCG6A360752X4

Single Packaged Gas/Heat Air Conditioner LX Series, 16 SEER, Single-Phase, 5 Ton, R410A, 81% AFUE B64-232
Single Packaged Gas/Heat Air Conditioner LX Series, 16 SEER, Single-Phase, 5 Ton, R410A, 81% AFUE
SEER: 16; EER: 12.0; Nom. Tons: 5; BtuH Cooling: 59,000; BtuH Heating Input: 125,000; BtuH Heating Output: 101,000; Volts: 208/230; Phase: Single; Nom. CFM: 1,825; Min. Circuit Amps: 38.0; Refrigerant: R410A; Width: 45-3/4"; Height: 50"; Depth: 51-1/4"; Wt. Lbs.: 548;
Brand: Coleman Mfg #: PCG6B601252X4

Single Packaged Gas/Heat Air Conditioner LX Series, 16 SEER, Single-Phase, 5 Ton, R410A, 81% AFUE B64-231
Single Packaged Gas/Heat Air Conditioner LX Series, 16 SEER, Single-Phase, 5 Ton, R410A, 81% AFUE
SEER: 16; EER: 12.0; Nom. Tons: 5; BtuH Cooling: 59,000; BtuH Heating Input: 100,000; BtuH Heating Output: 80,000; Volts: 208/230; Phase: Single; Nom. CFM: 1,825; Min. Circuit Amps: 38.0; Refrigerant: R410A; Width: 45-3/4"; Height: 50"; Depth: 51-1/4"; Wt. Lbs.: 541;
Brand: Coleman Mfg #: PCG6B601002X4

Heat Pump 16 SEER, Single-Phase, 3 Ton, R410A B61-218
Heat Pump 16 SEER, Single-Phase, 3 Ton, R410A
SEER: 16; EER: 13; Nom. Tons: 3; BtuH Cooling: 36,000; BtuH Heating Input: 36,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.0; COP: 3.36; Min. Circuit Amps: 22.0; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 35-1/4"; Height: 39-1/2";…
Brand: Coleman Mfg #: CH6B3621S

Heat Pump 16 SEER, Two-Stage, Single-Phase, 3 Tons, R410A B61-612
Heat Pump 16 SEER, Two-Stage, Single-Phase, 3 Tons, R410A
SEER: 16; EER: 13.0; Nom. Tons: 3; BtuH Cooling: 36,000; BtuH Heating Input: 36,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.0; COP: 4.4; Min. Circuit Amps: 19.5; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 40"; Depth:…
Brand: Goodman Mfg #: GSZC160361

Heat Pump 16 SEER, Two-Stage, Single-Phase, 5 Tons, R410A B61-614
Heat Pump 16 SEER, Two-Stage, Single-Phase, 5 Tons, R410A
SEER: 16; EER: 12.50; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.5; COP: 4.83; Min. Circuit Amps: 31.4; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 35-1/2"; Height: 40";…
Brand: Goodman Mfg #: GSZC160601

Heat Pump 16 SEER, Single-Phase, 5 Ton, R410A B61-221
Heat Pump 16 SEER, Single-Phase, 5 Ton, R410A
SEER: 16; EER: 13; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.0; COP: 3.36; Min. Circuit Amps: 32.4; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 38"; Height: 46"; Depth:…
Brand: Coleman Mfg #: CH6B6021S

Single Packaged Gas/Heat Air Conditioner LX Series, 16 SEER, Single-Phase, 5 Ton, R410A, 81% AFUE B64-230
Single Packaged Gas/Heat Air Conditioner LX Series, 16 SEER, Single-Phase, 5 Ton, R410A, 81% AFUE
SEER: 16; EER: 12.0; Nom. Tons: 5; BtuH Cooling: 59,000; BtuH Heating Input: 65,000; BtuH Heating Output: 52,000; Volts: 208/230; Phase: Single; Nom. CFM: 1,825; Min. Circuit Amps: 38.0; Refrigerant: R410A; Width: 45-3/4"; Height: 50"; Depth: 51-1/4"; Wt. Lbs.: 537;
Brand: Coleman Mfg #: PCG6B600652X4

Heat Pump 16 SEER, Single-Phase, 3 Ton, R410A B77-554
Heat Pump 16 SEER, Single-Phase, 3 Ton, R410A
SEER: 16; EER: 13.0; Nom. Tons: 3; BtuH Cooling: 36,000; BtuH Heating Input: 36,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 9.0; COP: 4.99; Min. Circuit Amps: 18.9; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 40"; Depth:…
Brand: Goodman Mfg #: GSZ160361

Air Conditioning Condensing Unit 16 SEER, Two-Stage, Single-Phase, 3 Tons, R410A B61-604
Air Conditioning Condensing Unit 16 SEER, Two-Stage, Single-Phase, 3 Tons, R410A
SEER: 16; EER: 13.0; Nom. Tons: 3; BtuH Cooling: 36,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 19.7; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-3/4"; Height: 36-1/2"; Depth: 35-3/4"; Wt. Lbs.: 201; OEM TXV: B14-850;
Brand: Goodman Mfg #: GSXC160361

Heat Pump 16 SEER, Single-Phase, 5 Ton, R410A B77-557
Heat Pump 16 SEER, Single-Phase, 5 Ton, R410A
SEER: 16; EER: 12.5; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 9.0; COP: 4.45; Min. Circuit Amps: 37.0; Max. Fuse Size: 60; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 35-1/2"; Height: 40";…
Brand: Goodman Mfg #: GSZ160601

Air Conditioning Condensing Unit 16 SEER, Single-Phase, 3 Ton, R410A B73-976
Air Conditioning Condensing Unit 16 SEER, Single-Phase, 3 Ton, R410A
SEER: 16; EER: 12.2; Nom. Tons: 3; BtuH Cooling: 34,800; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 18.7; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 29"; Height: 38-1/4"; Depth: 29"; Wt. Lbs.: 162; OEM TXV: B18-725;
Brand: Goodman Mfg #: GSX160361

Air Conditioning Condensing Unit 16 SEER, Single-Phase, 5 Ton, R410A B73-979
Air Conditioning Condensing Unit 16 SEER, Single-Phase, 5 Ton, R410A
SEER: 16; EER: 12.5; Nom. Tons: 5; BtuH Cooling: 54,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 29.6; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 38-1/4"; Depth: 35-1/2"; Wt. Lbs.: 279; OEM TXV: B18-727;
Brand: Goodman Mfg #: GSX160601

Air Conditioning Condensing Unit 16 SEER, Single-Phase, 3 Ton, R410A B75-682
Air Conditioning Condensing Unit 16 SEER, Single-Phase, 3 Ton, R410A
SEER: 16; EER: 12.5; Nom. Tons: 3; BtuH Cooling: 36,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 20.4; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 36-1/4"; Depth: 35-1/2"; Wt. Lbs.: 182; OEM TXV: B18-725;
Brand: Goodman Mfg #: GSX160371

Single Packaged Air Conditioner 16 SEER, Single-Phase, 3 Ton, R410A B64-149
Single Packaged Air Conditioner 16 SEER, Single-Phase, 3 Ton, R410A
SEER: 16; EER: 12.5; Nom. Tons: 3; BtuH Cooling: 36,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Nom. CFM: 1,275; Min. Circuit Amps: 23.2; Max. Fuse Size: 35; Refrigerant: R410A; Width: 35-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 461;
Brand: Coleman Mfg #: PCE6A3624

Single Packaged Air Conditioner 16 SEER, Single-Phase, 5 Ton, R410A B64-151
Single Packaged Air Conditioner 16 SEER, Single-Phase, 5 Ton, R410A
SEER: 16; EER: 12.0; Nom. Tons: 5; BtuH Cooling: 59,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Nom. CFM: 1,825; Min. Circuit Amps: 38.0; Max. Fuse Size: 60; Refrigerant: R410A; Width: 45-3/4"; Height: 50"; Depth: 51-1/4"; Wt. Lbs.: 500;
Brand: Coleman Mfg #: PCE6B6024

Air Conditioning Condensing Unit 16 SEER, Two-Stage, Single-Phase, 5 Tons, R410A B61-606
Air Conditioning Condensing Unit 16 SEER, Two-Stage, Single-Phase, 5 Tons, R410A
SEER: 16; EER: 13.0; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 31.4; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 35-3/4"; Height: 42-1/4"; Depth: 35-3/4"; Wt. Lbs.: 304; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSXC160601

Air Conditioning Condensing Unit 16 SEER, Single-Phase, 3 Ton, R410A B60-822
Air Conditioning Condensing Unit 16 SEER, Single-Phase, 3 Ton, R410A
SEER: 16; EER: 13.0; Nom. Tons: 3; BtuH Cooling: 34,800; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 18.6; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 29"; Height: 39-1/2"; Depth: 29"; Wt. Lbs.: 162; OEM TXV: B18-725;
Brand: Goodman Mfg #: GSX16S361

Single Packaged Heat Pump 16 SEER, 5 Ton, Single-Phase, R410A B79-388
Single Packaged Heat Pump 16 SEER, 5 Ton, Single-Phase, R410A
SEER: 16; EER: 12.5; Nom. Tons: 5; BtuH Cooling: 57,500; BtuH Heating Input: 57,200; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.2; COP: 3.6; Nom. CFM: 1,800; Min. Circuit Amps: 42.3; Refrigerant: R410A; Width: 45-3/4"; Height: 55"; Depth: 51-1/4"; Wt. Lbs.: 523;
Brand: Coleman Mfg #: PHE6B6021

Single Packaged Heat Pump 16 SEER, Single-Phase, 3 Ton, R410A, Horizontal B76-933
Single Packaged Heat Pump 16 SEER, Single-Phase, 3 Ton, R410A, Horizontal
SEER: 16; EER: 13; Nom. Tons: 3; BtuH Cooling: 36,000; BtuH Heating Input: 32,200; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 3.8; Nom. CFM: 1,200; Min. Circuit Amps: 27.0; Refrigerant: R410A; Width: 66"; Height: 35"; Depth: 34"; Wt. Lbs.: 375;
Brand: Goodman Mfg #: GPH1636H41

Single Packaged Gas/Electric Air Conditioner 16 SEER, Single-Phase, 3 Ton, 81% AFUE, R410A, Multi-Position B75-674
Single Packaged Gas/Electric Air Conditioner 16 SEER, Single-Phase, 3 Ton, 81% AFUE, R410A, Multi-Position
SEER: 16; EER: 12.0; Nom. Tons: 3; BtuH Cooling: 34,200; BtuH Heating Input: 80,000; BtuH Heating Output: 62,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Nom. CFM: 1,200; Min. Circuit Amps: 24.4; Refrigerant: R410A; Width: 47"; Height: 42-3/4"; Depth: 51"; Wt. Lbs.: 470;
Brand: Goodman Mfg #: GPG1636080M41

Gas/Electric Packaged Air Conditioner Up to 17 IEER/13EER, 81% Thermal Efficiency, Three-Phase, 5 Ton, R510A, High Heat B64-750
Gas/Electric Packaged Air Conditioner Up to 17 IEER/13EER, 81% Thermal Efficiency, Three-Phase, 5 Ton, R510A, High Heat
SEER: 16.5; EER: 12.1; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 140,000; BtuH Heating Output: 113,400; Volts: 460V; Phase: Three; Motor Type: Direct Drive; Nom. CFM: 2,000; Min. Circuit Amps: 16.4; Refrigerant: R410A; Width: 74"; Height: 43-1/2"; Depth: 48-5/16"; Wt. Lbs.: 655;
Brand: Daikin Mfg #: DRG0604DH00001S

Single Packaged Heat Pump 16 SEER, Single-Phase, 5 Ton, R410A, Multi-Position B63-645
Single Packaged Heat Pump 16 SEER, Single-Phase, 5 Ton, R410A, Multi-Position
SEER: 16; EER: 12.0; Nom. Tons: 5; BtuH Cooling: 58,000; BtuH Heating Input: 58,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.2; COP: 3.7; Nom. CFM: 1,800; Min. Circuit Amps: 44.0; Refrigerant: R410A; Width: 48-49/250"; Height: 42-21/25"; Depth: 73-189/200"; Wt. Lbs.: 688;
Brand: Goodman Mfg #: GPH1660M41

Heat Pump LX Series, 16 SEER, Single-Phase, 3 Ton, R410A B62-071
Heat Pump LX Series, 16 SEER, Single-Phase, 3 Ton, R410A
SEER: 16; EER: 11.5; Nom. Tons: 3; BtuH Cooling: 35,000; BtuH Heating Input: 34,600; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.75; COP: 3.6; Min. Circuit Amps: 21.0; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29-1/4"; Height: 39-1/2";…
Brand: Coleman Mfg #: CH16B3622S
FTL Finance
Powered by Site Search powered by SLI Systems
Select products to compare.