346 Results

1, 3, 2, HVAC Equipment

Heat Pump 20 SEER, Single-Phase, Modulating, 2 Ton, R410A B79-689
Heat Pump 20 SEER, Single-Phase, Modulating, 2 Ton, R410A
SEER: 20; EER: 13.5; Nom. Tons: 2; BtuH Cooling: 24,000; BtuH Heating Input: 24,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 11.0; COP: 3.86; Min. Circuit Amps: 17.7; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 32"; Height: 40-1/4"; Depth:…
Brand: Coleman Mfg #: HC20B2421S

Air Conditioning Condensing Unit Horizontal Discharge, 13 SEER, Single-Phase, 3 Ton, R410A B91-942
Air Conditioning Condensing Unit Horizontal Discharge, 13 SEER, Single-Phase, 3 Ton, R410A
SEER: 13; EER: 11.7; Nom. Tons: 3; BtuH Cooling: 36,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 23.1; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 45"; Height: 37-1/4"; Depth: 20"; Wt. Lbs.: 215; OEM TXV: B19-659; OEM TXV for…
Brand: Coleman Mfg #: TCHD36S41S3

Air Conditioning Condensing Unit Horizontal Discharge, 14 SEER, Single-Phase, 3 Ton, R410A B60-175
Air Conditioning Condensing Unit Horizontal Discharge, 14 SEER, Single-Phase, 3 Ton, R410A
SEER: 14; EER: 12.2; Nom. Tons: 3; BtuH Cooling: 36,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 19.1; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 45"; Height: 37-1/4"; Depth: 20"; Wt. Lbs.: 215; OEM TXV: B20-259; OEM TXV for…
Brand: Coleman Mfg #: TCHE36S41S1

Heat Pump 14 SEER, Single-Phase, 2 Ton, R410A B75-914
Heat Pump 14 SEER, Single-Phase, 2 Ton, R410A
SEER: 14; EER: 11.5; Nom. Tons: 2; BtuH Cooling: 24,000; BtuH Heating Input: 24,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.2; COP: 4.39; Min. Circuit Amps: 10.6; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29"; Height: 34-1/2"; Depth:…
Brand: Goodman Mfg #: GSZ140241

Single Packaged Gas/Electric  Air Conditioner 13.4 SEER2, Single-Phase, 2 Ton, 81% AFUE, R410A, Multi-Position B66-149
Single Packaged Gas/Electric Air Conditioner 13.4 SEER2, Single-Phase, 2 Ton, 81% AFUE, R410A, Multi-Position
SEER2: 13.4; EER2: 10.6; Nom. Tons: 2; BtuH Cooling: 23,000; BtuH Heating Input: 60,000; BtuH Heating Output: 48,600; Volts: 208/230; Phase: Single; Motor Type: ECM; Nom. CFM: 800; Min. Circuit Amps: 21.6; Refrigerant: R410A; Width: 47"; Height: 32"; Depth: 51"; Wt. Lbs.: 417;
Brand: Goodman Mfg #: GPGM32406041

Single Packaged Gas/Electric  Air Conditioner 13.4 SEER2, Single-Phase, 3 Ton, 81% AFUE, R410A, Multi-Position B66-154
Single Packaged Gas/Electric Air Conditioner 13.4 SEER2, Single-Phase, 3 Ton, 81% AFUE, R410A, Multi-Position
SEER2: 13.4; EER2: 10.6; Nom. Tons: 3; BtuH Cooling: 34,200; BtuH Heating Input: 80,000; BtuH Heating Output: 64,800; Volts: 208/230; Phase: Single; Motor Type: ECM; Nom. CFM: 1,200; Min. Circuit Amps: 22.8; Refrigerant: R410A; Width: 47"; Height: 32"; Depth: 51"; Wt. Lbs.: 458;
Brand: Goodman Mfg #: GPGM33608041

Single Packaged Heat Pump GPHM3 Series, 13.4 SEER2, Single-Phase, 3 Ton, R410A, Multi-Position B66-344
Single Packaged Heat Pump GPHM3 Series, 13.4 SEER2, Single-Phase, 3 Ton, R410A, Multi-Position
SEER2: 13.4; Nom. Tons: 3; BtuH Cooling: 34,200; BtuH Heating Input: 33,600; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF2: 6.7; COP: 3.58; Nom. CFM: 1,200; Min. Circuit Amps: 24.4; Refrigerant: R410A; Width: 47"; Height: 34-3/4"; Depth: 51"; Wt. Lbs.: 400;
Brand: Goodman Mfg #: GPHM33641

Air Conditioning Condensing Unit 13.4 SEER2, Single-Phase, 2 Ton, R410A B66-581
Air Conditioning Condensing Unit 13.4 SEER2, Single-Phase, 2 Ton, R410A
SEER2: 13.4; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 11.2; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 26"; Height: 32-1/2"; Depth: 26"; Wt. Lbs.: 125; OEM TXV: B18-099;
Brand: Goodman Mfg #: GSXN3N2410

Air Conditioning Condensing Unit 13 SEER, Single-Phase, 3 Ton, R410A B98-347
Air Conditioning Condensing Unit 13 SEER, Single-Phase, 3 Ton, R410A
SEER: 13; EER: 11.0; Nom. Tons: 3; BtuH Cooling: 36,800; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 18.8; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 26"; Height: 27-1/2"; Depth: 26"; Wt. Lbs.: 118; OEM TXV: B14-850;
Brand: Goodman Mfg #: GSX130361

Heat Pump 14 SEER, Single-Phase, 3 Ton, R410A B64-281
Heat Pump 14 SEER, Single-Phase, 3 Ton, R410A
SEER: 14; EER: 11.5; Nom. Tons: 3; BtuH Cooling: 36,000; BtuH Heating Input: 36,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.2; COP: 4.28; Min. Circuit Amps: 19.3; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 29"; Height: 36-1/4"; Depth:…
Brand: Goodman Mfg #: GSZ140361

Air Conditioning Condensing Unit 13 SEER, Single-Phase, 2 Ton, R410A B61-811
Air Conditioning Condensing Unit 13 SEER, Single-Phase, 2 Ton, R410A
SEER: 13; EER: 11.0; Nom. Tons: 2; BtuH Cooling: 23,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 10.3; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 23"; Height: 27-1/2"; Depth: 23"; Wt. Lbs.: 103; OEM TXV: B18-099;
Brand: Goodman Mfg #: GSX130241

Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 2 Ton, R410A B62-869
Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 2 Ton, R410A
SEER: 13; EER: 12.5; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 11.4; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 24"; Height: 26-3/4"; Depth: 24"; Wt. Lbs.: 130; OEM TXV: B20-469; OEM TXV for…
Brand: Evcon Mfg #: RAC13L24B24S

Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 3 Ton, R410A, 81% AFUE B64-193
Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 3 Ton, R410A, 81% AFUE
SEER: 14; EER: 11.8; Nom. Tons: 3; BtuH Cooling: 35,800; BtuH Heating Input: 50,000; BtuH Heating Output: 40,000; Volts: 208/230V; Phase: Single; Nom. CFM: 1,165; Min. Circuit Amps: 23.9; Refrigerant: R410A; Width: 35-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 359;
Brand: Coleman Mfg #: PCG4A360502X4

Single Packaged Heat Pump GPHM3 Series, 13.4 SEER2, Single-Phase, 2 Ton, R410A, Multi-Position B66-342
Single Packaged Heat Pump GPHM3 Series, 13.4 SEER2, Single-Phase, 2 Ton, R410A, Multi-Position
SEER2: 13.4; Nom. Tons: 2; BtuH Cooling: 24,000; BtuH Heating Input: 22,800; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF2: 6.7; COP: 3.46; Nom. CFM: 850; Min. Circuit Amps: 21.4; Refrigerant: R410A; Width: 47"; Height: 34-3/4"; Depth: 51"; Wt. Lbs.: 380;
Brand: Goodman Mfg #: GPHM32441

Air Conditioning Condensing Unit 13.4 SEER2, Single-Phase, 3 Ton, R410A B66-583
Air Conditioning Condensing Unit 13.4 SEER2, Single-Phase, 3 Ton, R410A
SEER2: 13.4; Nom. Tons: 3; BtuH Cooling: 36,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 18.6; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 29"; Height: 32-1/2"; Depth: 29"; Wt. Lbs.: 153; OEM TXV: B14-850;
Brand: Goodman Mfg #: GSXN3N3610

Heat Pump LX Series, 14.3 SEER2, Single-Phase, 2 Ton, R410A B65-743
Heat Pump LX Series, 14.3 SEER2, Single-Phase, 2 Ton, R410A
SEER2: 14.3; Nom. Tons: 2; BtuH Cooling: 23,600; BtuH Heating Input: 22,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.2; HSPF2: 8.2; COP: 3.58; Min. Circuit Amps: 13.4; Max. Fuse Size: 20; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 24"; Height: 36-1/4";…
Brand: Coleman Mfg #: THE2B24T21S

Heat Pump LX Series, 14.3 SEER2, Single-Phase, 3 Ton, R410A B65-745
Heat Pump LX Series, 14.3 SEER2, Single-Phase, 3 Ton, R410A
SEER2: 14.3; Nom. Tons: 3; BtuH Cooling: 35,000; BtuH Heating Input: 32,600; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.2; HSPF2: 8.2; COP: 3.42; Min. Circuit Amps: 20.3; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 31-3/4"; Height: 33-1/4";…
Brand: Coleman Mfg #: THE2B36T21S

Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 3 Ton, R410A B65-959
Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 3 Ton, R410A
SEER2: 14.3; Nom. Tons: 3; BtuH Cooling: 34,400; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 18.6; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 39-1/2"; Depth: 35-1/2"; Wt. Lbs.: 202; OEM TXV: B14-850;
Brand: Goodman Mfg #: GSXM403610

Air Conditioning Condensing Unit 17.2 SEER2, Two-Stage, Single-Phase, 2 Ton, R410A B65-722
Air Conditioning Condensing Unit 17.2 SEER2, Two-Stage, Single-Phase, 2 Ton, R410A
SEER2: 17.2; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 15.3; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 35-1/2"; Height: 39-1/2"; Depth: 35-1/2"; Wt. Lbs.: 214; OEM TXV: B18-099;
Brand: Goodman Mfg #: GSXC702410

Air Conditioning Condensing Unit LX Series, 17 SEER, Single-Phase, 2 Ton, R410A B78-418
Air Conditioning Condensing Unit LX Series, 17 SEER, Single-Phase, 2 Ton, R410A
SEER: 17; EER: 13; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 16.4; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29-1/4"; Height: 30"; Depth: 29-1/4"; Wt. Lbs.: 150; OEM TXV: B19-657; OEM TXV…
Brand: Coleman Mfg #: CC7B2421S

Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 3 Ton, R410A B62-222
Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 3 Ton, R410A
SEER: 13; EER: 11; Nom. Tons: 3; BtuH Cooling: 35,000; Volts: 208/230; Phase: Single; Min. Circuit Amps: 19.8; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 24; Height: 33-1/4"; Depth: 24; Wt. Lbs.: 145; OEM TXV: B19-657; OEM TXV for C Series Coils:…
Brand: Evcon Mfg #: RAC13L36B24S

Horizontal Discharge Heat Pump 17 SEER, Single-Phase, Modulating, 3 Ton, R410A B64-414
Horizontal Discharge Heat Pump 17 SEER, Single-Phase, Modulating, 3 Ton, R410A
SEER: 18; EER: 10; Nom. Tons: 3; BtuH Cooling: 36,000; BtuH Heating Input: 36,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 10.5; COP: 3.4; Min. Circuit Amps: 23; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 37-3/8"; Height: 33"; Depth:…
Brand: Coleman Mfg #: HMH72B361S

Horizontal Discharge Heat Pump 17 SEER, Single-Phase, Modulating, 2 Ton, R410A B64-413
Horizontal Discharge Heat Pump 17 SEER, Single-Phase, Modulating, 2 Ton, R410A
SEER: 17.5; EER: 10; Nom. Tons: 2; BtuH Cooling: 22,200; BtuH Heating Input: 22,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9; COP: 3.36; Min. Circuit Amps: 15; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 5/8"; Refrigerant: R410A; Width: 33-7/8"; Height: 26-3/8"; Depth:…
Brand: Coleman Mfg #: HMH72B241S

Air Conditioning Condensing Unit LX Series, 17 SEER, Single-Phase, 3 Ton, R410A B78-420
Air Conditioning Condensing Unit LX Series, 17 SEER, Single-Phase, 3 Ton, R410A
SEER: 17; EER: 12.5; Nom. Tons: 3; BtuH Cooling: 36,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 22.0; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 35-1/4"; Height: 36-1/4"; Depth: 31-3/4"; Wt. Lbs.: 175; OEM TXV: B19-657; OEM…
Brand: Coleman Mfg #: CC7B3621S