Air Conditioning Condensing Unit 16 SEER, Two-Stage, Single-Phase, 2 Tons, R410A B61-603
Air Conditioning Condensing Unit 16 SEER, Two-Stage, Single-Phase, 2 Tons, R410A
SEER: 16; EER: 13.5; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 13.6; Max. Fuse Size: 20; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29-1/4"; Height: 32-1/2"; Depth: 29-1/4"; Wt. Lbs.: 180; OEM TXV: B18-099;
Brand: Goodman Mfg #: GSXC160241

Air Conditioning Condensing Unit 16 SEER, Two-Stage, Single-Phase, 3 Tons, R410A B61-604
Air Conditioning Condensing Unit 16 SEER, Two-Stage, Single-Phase, 3 Tons, R410A
SEER: 16; EER: 13.0; Nom. Tons: 3; BtuH Cooling: 36,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 19.7; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-3/4"; Height: 36-1/2"; Depth: 35-3/4"; Wt. Lbs.: 201; OEM TXV: B14-850;
Brand: Goodman Mfg #: GSXC160361

Single Packaged Heat Pump 14 SEER, Single-Phase, 2 Tons, R410A, Multi-Position B76-801
Single Packaged Heat Pump 14 SEER, Single-Phase, 2 Tons, R410A, Multi-Position
SEER: 14; EER: 11; Nom. Tons: 2; BtuH Cooling: 24,000; BtuH Heating Input: 23,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 3.6; Nom. CFM: 850; Min. Circuit Amps: 21.8; Refrigerant: R410A; Width: 47"; Height: 34-3/4"; Depth: 51"; Wt. Lbs.: 380;
Brand: Goodman Mfg #: GPH1424M41

Air Conditioning Condensing Unit 16 SEER, Single-Phase, 3 Ton, R410A B73-976
Air Conditioning Condensing Unit 16 SEER, Single-Phase, 3 Ton, R410A
SEER: 16; EER: 12.2; Nom. Tons: 3; BtuH Cooling: 34,800; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 18.7; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 29"; Height: 38-1/4"; Depth: 29"; Wt. Lbs.: 162; OEM TXV: B18-725;
Brand: Goodman Mfg #: GSX160361

Dual Fuel Packaged Unit 13.4 SEER2, Single-Phase, 2 Ton, R410A, 81% AFUE, 6.7 HSPF2 B66-169
Dual Fuel Packaged Unit 13.4 SEER2, Single-Phase, 2 Ton, R410A, 81% AFUE, 6.7 HSPF2
SEER2: 13.4; EER2: 10.6; Nom. Tons: 2; BtuH Cooling: 23,800; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF2: 6.7; Nom. CFM: 850; Min. Circuit Amps: 20.8; Refrigerant: R410A; Width: 47"; Height: 32"; Depth: 51"; Wt. Lbs.: 420;
Brand: Goodman Mfg #: GPDM32406041

Air Conditioning Condensing Unit RAC134 Series, 13.4 SEER2, Single-Phase, 3 Ton, R410A B66-466
Air Conditioning Condensing Unit RAC134 Series, 13.4 SEER2, Single-Phase, 3 Ton, R410A
SEER2: 13.4; EER2: 11.25; Nom. Tons: 3; BtuH Cooling: 36,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 19.6; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29-1/4"; Height: 30"; Depth: 29-1/4"; Wt. Lbs.: 150; OEM TXV: B19-659; OEM…
Brand: Evcon Mfg #: RAC13436B21S

Air Conditioning Condensing Unit RAC134 Series, 13.4 SEER2, Single-Phase, 2 Ton, R410A B66-464
Air Conditioning Condensing Unit RAC134 Series, 13.4 SEER2, Single-Phase, 2 Ton, R410A
SEER2: 13.4; EER2: 11.5; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 11.3; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 24"; Height: 33-1/4"; Depth: 24"; Wt. Lbs.: 135; OEM TXV: B19-657; OEM TXV…
Brand: Evcon Mfg #: RAC13424B21S

Heat Pump 14 SEER, Single-Phase, 2 Ton, R410A B79-085
Heat Pump 14 SEER, Single-Phase, 2 Ton, R410A
SEER: 14; EER: 11.5; Nom. Tons: 2; BtuH Cooling: 23,200; BtuH Heating Input: 23,200; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.2; COP: 4.73; Min. Circuit Amps: 14.7; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29"; Height: 34-1/2"; Depth:…
Brand: Goodman Mfg #: GSZ140251

Air Conditioning Condensing Unit 16 SEER, Single-Phase, 3 Ton, R410A B75-682
Air Conditioning Condensing Unit 16 SEER, Single-Phase, 3 Ton, R410A
SEER: 16; EER: 12.5; Nom. Tons: 3; BtuH Cooling: 36,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 20.4; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 36-1/4"; Depth: 35-1/2"; Wt. Lbs.: 182; OEM TXV: B18-725;
Brand: Goodman Mfg #: GSX160371

Single Packaged Gas/Electric  Air Conditioner 13.4 SEER2, Single-Phase, 2 Ton, 81% AFUE, R410A, Multi-Position B66-148
Single Packaged Gas/Electric Air Conditioner 13.4 SEER2, Single-Phase, 2 Ton, 81% AFUE, R410A, Multi-Position
SEER2: 13.4; EER2: 10.6; Nom. Tons: 2; BtuH Cooling: 23,000; BtuH Heating Input: 40,000; BtuH Heating Output: 32,400; Volts: 208/230; Phase: Single; Motor Type: ECM; Nom. CFM: 800; Min. Circuit Amps: 21.6; Refrigerant: R410A; Width: 47"; Height: 32"; Depth: 51"; Wt. Lbs.: 412;
Brand: Goodman Mfg #: GPGM32404041

Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 2 Ton, R410A, Southwest Region Only B62-066
Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 2 Ton, R410A, Southwest Region Only
SEER: 14; EER: 12.2; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 14.8; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29-1/4"; Height: 30"; Depth: 29-1/4"; Wt. Lbs.: 135; OEM TXV: B20-469; OEM TXV…
Brand: Coleman Mfg #: TW4B2422S

Air Conditioning Condensing Unit 18 SEER, Two-Stage, Single-Phase, 2 Tons, R410A B61-599
Air Conditioning Condensing Unit 18 SEER, Two-Stage, Single-Phase, 2 Tons, R410A
SEER: 18; EER: 14.0; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 15.3; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 35-3/4"; Height: 40"; Depth: 35-3/4"; Wt. Lbs.: 236; OEM TXV: B18-099;
Brand: Goodman Mfg #: GSXC180241

Single Packaged Air Conditioner GPCM3 Series, 13.4 SEER2, 3 Ton, R410A, Multi-Position B66-338
Single Packaged Air Conditioner GPCM3 Series, 13.4 SEER2, 3 Ton, R410A, Multi-Position
SEER2: 13.4; EER2: 10.6; Nom. Tons: 3; BtuH Cooling: 34,200; Volts: 208/230; Phase: Single; Motor Type: ECM; Nom. CFM: 1,200; Min. Circuit Amps: 26.1; Max. Fuse Size: 40; Refrigerant: R410A; Width: 47"; Height: 34-3/4"; Depth: 51"; Wt. Lbs.: 365;
Brand: Goodman Mfg #: GPCM33641

Horizontal Discharge Air Conditioning Condensing Unit 17 SEER2, Single-Phase, Modulating, 3 Ton, R410A B66-300
Horizontal Discharge Air Conditioning Condensing Unit 17 SEER2, Single-Phase, Modulating, 3 Ton, R410A
SEER2: 17.0; EER2: 10.0; Nom. Tons: 3; BtuH Cooling: 36,000; Volts: 208/230; Phase: Single; Min. Circuit Amps: 23.0; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 5/8"; Refrigerant: R410A; Width: 35-3/8"; Height: 29-1/2"; Depth: 13-3/8"; Wt. Lbs.: 117; OEM TXV: B19-657; OEM TXV for X…
Brand: Coleman Mfg #: HMCG22B361S

Air Conditioning Condensing Unit 18 SEER, Two-Stage, Single-Phase, 3 Tons, R410A B61-600
Air Conditioning Condensing Unit 18 SEER, Two-Stage, Single-Phase, 3 Tons, R410A
SEER: 18; EER: 13.5; Nom. Tons: 3; BtuH Cooling: 36,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 21.3; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-3/4"; Height: 40"; Depth: 35-3/4"; Wt. Lbs.: 238; OEM TXV: B14-850;
Brand: Goodman Mfg #: GSXC180361

Heat Pump LX Series, 14 SEER, Single-Phase, 2 Ton, R410A B62-863
Heat Pump LX Series, 14 SEER, Single-Phase, 2 Ton, R410A
SEER: 14; EER: 12.0; Nom. Tons: 2; BtuH Cooling: 25,000; BtuH Heating Input: 22,200; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 9.0; COP: 3.68; Min. Circuit Amps: 14.1; Max. Fuse Size: 20; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 24"; Height: 33-1/4"; Depth:…
Brand: Coleman Mfg #: TE4B2421S

Air Conditioning Condensing Unit 14 SEER, Single-Phase, 3 Ton, R410A B76-581
Air Conditioning Condensing Unit 14 SEER, Single-Phase, 3 Ton, R410A
SEER: 14; EER: 12.2; Nom. Tons: 3; BtuH Cooling: 36,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 18.7; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 29"; Height: 32-1/2"; Depth: 29"; Wt. Lbs.: 162; OEM TXV: B14-850;
Brand: Goodman Mfg #: GSX140371

Heat Pump LX Series, 14 SEER, Single-Phase, 3 Ton, R410A B78-401
Heat Pump LX Series, 14 SEER, Single-Phase, 3 Ton, R410A
SEER: 14; EER: 12.5; Nom. Tons: 3; BtuH Cooling: 35,000; BtuH Heating Input: 35,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.9; COP: 3.76; Min. Circuit Amps: 20.5; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 35-1/4"; Height: 39-1/2";…
Brand: Evcon Mfg #: RHP14L35B23S

Single Packaged Air Conditioner 16 SEER, Single-Phase, 3 Ton, R410A B64-149
Single Packaged Air Conditioner 16 SEER, Single-Phase, 3 Ton, R410A
SEER: 16; EER: 12.5; Nom. Tons: 3; BtuH Cooling: 36,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Nom. CFM: 1,275; Min. Circuit Amps: 23.2; Max. Fuse Size: 35; Refrigerant: R410A; Width: 35-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 461;
Brand: Coleman Mfg #: PCE6A3624

Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 2 Ton, R410A B61-294
Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 2 Ton, R410A
SEER: 14; EER: 12.00; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 14.8; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29-1/4"; Height: 26-3/4"; Depth: 29-1/4"; Wt. Lbs.: 145; OEM TXV: B20-469; OEM…
Brand: Evcon Mfg #: RAC14L24B23S

Air Conditioning Condensing Unit 14 SEER, Single-Phase, 2 Ton, R410A B76-579
Air Conditioning Condensing Unit 14 SEER, Single-Phase, 2 Ton, R410A
SEER: 14; EER: 12.2; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 14.3; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 26"; Height: 27-1/2"; Depth: 26"; Wt. Lbs.: 131; OEM TXV: B18-099;
Brand: Goodman Mfg #: GSX140251

Heat Pump LX Series, 14 SEER, Single-Phase, 2 Ton, R410A B62-882
Heat Pump LX Series, 14 SEER, Single-Phase, 2 Ton, R410A
SEER: 14; EER: 12.0; Nom. Tons: 2; BtuH Cooling: 25,000; BtuH Heating Input: 22,200; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 9.0; COP: 3.68; Min. Circuit Amps: 14.1; Max. Fuse Size: 20; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 24"; Height: 33-1/4"; Depth:…
Brand: Evcon Mfg #: REP14L24B21S

Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 2 Ton, R410A, 81% AFUE, LOWNOx B63-655
Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 2 Ton, R410A, 81% AFUE, LOWNOx
SEER: 14; EER: 11.0; Nom. Tons: 2; BtuH Cooling: 23,600; BtuH Heating Input: 50,000; BtuH Heating Output: 41,000; Volts: 208/230V; Phase: Single; Nom. CFM: 800; Min. Circuit Amps: 16.9; Refrigerant: R410A; Width: 35-3/4"; Height: 44"; Depth: 51-1/4"; Wt. Lbs.: 341;
Brand: Coleman Mfg #: PCG4A240502L1

Single Packaged Gas/Electric Air Conditioner 15.2 SEER2, Single-Phase, 2 Ton, 81% AFUE, R410A, Multi-Position B66-163
Single Packaged Gas/Electric Air Conditioner 15.2 SEER2, Single-Phase, 2 Ton, 81% AFUE, R410A, Multi-Position
SEER2: 15.2; EER2: 11.2; Nom. Tons: 2; BtuH Cooling: 23,000; BtuH Heating Input: 60,000; BtuH Heating Output: 48,600; Volts: 208/230; Phase: Single; Motor Type: ECM; Nom. CFM: 800; Min. Circuit Amps: 18.4; Refrigerant: R410A; Width: 47"; Height: 32"; Depth: 51"; Wt. Lbs.: 370;
Brand: Goodman Mfg #: GPGM52406041