Single Packaged Gas/Electric Air Conditioner 16 SEER, Single-Phase, 4 Ton, 81% AFUE, R410A, Multi-Position B75-676
Single Packaged Gas/Electric Air Conditioner 16 SEER, Single-Phase, 4 Ton, 81% AFUE, R410A, Multi-Position
SEER: 16; EER: 12.0; Nom. Tons: 4; BtuH Cooling: 45,500; BtuH Heating Input: 100,000; BtuH Heating Output: 78,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Nom. CFM: 1,300; Min. Circuit Amps: 33.3; Refrigerant: R410A; Width: 47"; Height: 42-3/4"; Depth: 51"; Wt. Lbs.: 490;
Brand: Goodman Mfg #: GPG1648100M41

Single Packaged Heat Pump 16 SEER, Single-Phase, 5 Ton, R410A, Horizontal B75-683
Single Packaged Heat Pump 16 SEER, Single-Phase, 5 Ton, R410A, Horizontal
SEER: 16; EER: 12; Nom. Tons: 5; BtuH Cooling: 57,500; BtuH Heating Input: 54,500; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.2; COP: 3.6; Nom. CFM: 1,700; Min. Circuit Amps: 40.0; Refrigerant: R410A; Width: 66"; Height: 38-3/4"; Depth: 34"; Wt. Lbs.: 405;
Brand: Goodman Mfg #: GPH1660H41

Gas/Electric Packaged Air Conditioner Up to 17 IEER/13 EER, 81% Thermal Efficiency, Three-Phase, 5 Ton, R510A, Medium Heat B64-749
Gas/Electric Packaged Air Conditioner Up to 17 IEER/13 EER, 81% Thermal Efficiency, Three-Phase, 5 Ton, R510A, Medium Heat
SEER: 16.5; EER: 12.1; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 115,000; BtuH Heating Output: 93,200; Volts: 460V; Phase: Three; Motor Type: Direct Drive; Nom. CFM: 2,000; Min. Circuit Amps: 16.4; Refrigerant: R410A; Width: 74"; Height: 43-1/2"; Depth: 48-5/16"; Wt. Lbs.: 655;
Brand: Daikin Mfg #: DRG0604DM00001S

Gas/Electric Packaged Air Conditioner Up to 17 SEER/13 EER, 81% Thermal Efficiency, Three-Phase, 5 Ton, R510A, Low Heat B64-748
Gas/Electric Packaged Air Conditioner Up to 17 SEER/13 EER, 81% Thermal Efficiency, Three-Phase, 5 Ton, R510A, Low Heat
SEER: 16.5; EER: 12.1; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 70,000; BtuH Heating Output: 56,700; Volts: 460V; Phase: Three; Motor Type: Direct Drive; Nom. CFM: 2,000; Min. Circuit Amps: 16.4; Refrigerant: R410A; Width: 74"; Height: 43-1/2"; Depth: 48-5/16"; Wt. Lbs.: 655;
Brand: Daikin Mfg #: DRG0604DL00001S

Single Packaged Air Conditioner Up To 17.1 SEER/13 EER, Single-Phase, 5 Ton, R410A B64-770
Single Packaged Air Conditioner Up To 17.1 SEER/13 EER, Single-Phase, 5 Ton, R410A
SEER: 16.5; EER: 12.1; Nom. Tons: 5; BtuH Cooling: 59,000; Volts: 208/230; Phase: Single; Motor Type: Direct Drive; Nom. CFM: 1,850; Min. Circuit Amps: 43.2; Refrigerant: R410A; Width: 74"; Height: 39-7/8"; Depth: 48-5/16"; Wt. Lbs.: 606;
Brand: Daikin Mfg #: DRC0601D000001S

Single Packaged Air Conditioner Up To 17.1 SEER/13 EER, Three-Phase, 5 Ton, R410A, 208/230V B64-773
Single Packaged Air Conditioner Up To 17.1 SEER/13 EER, Three-Phase, 5 Ton, R410A, 208/230V
SEER: 16.5; EER: 12.1; Nom. Tons: 5; BtuH Cooling: 59,000; Volts: 208/230; Phase: Three; Motor Type: Direct Drive; Nom. CFM: 1,850; Min. Circuit Amps: 29.8; Refrigerant: R410A; Width: 74"; Height: 43-1/2"; Depth: 48-5/16"; Wt. Lbs.: 606;
Brand: Daikin Mfg #: DRC0603D000001S

Single Packaged Air Conditioner Up To 17.1 SEER/13 EER, Three-Phase, 5 Ton, R410A, 460V B64-777
Single Packaged Air Conditioner Up To 17.1 SEER/13 EER, Three-Phase, 5 Ton, R410A, 460V
SEER: 16.5; EER: 12.1; Nom. Tons: 5; BtuH Cooling: 59,000; Volts: 460V; Phase: Three; Motor Type: Direct Drive; Nom. CFM: 1,850; Min. Circuit Amps: 13.6; Refrigerant: R410A; Width: 74"; Height: 43-1/2"; Depth: 48-5/16"; Wt. Lbs.: 606;
Brand: Daikin Mfg #: DRC0604D000001S

Single Packaged Heat Pump 16 SEER, Single-Phase, 4 Ton, R410A, Horizontal B76-935
Single Packaged Heat Pump 16 SEER, Single-Phase, 4 Ton, R410A, Horizontal
SEER: 16; EER: 12; Nom. Tons: 4; BtuH Cooling: 46,000; BtuH Heating Input: 44,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 3.8; Nom. CFM: 1,600; Min. Circuit Amps: 35.0; Refrigerant: R410A; Width: 66"; Height: 35"; Depth: 34"; Wt. Lbs.: 400;
Brand: Goodman Mfg #: GPH1648H41

Packaged Heat Pump 16 SEER, Single-Phase, Single-Stage, 5 Ton, R410A B60-887
Packaged Heat Pump 16 SEER, Single-Phase, Single-Stage, 5 Ton, R410A
SEER: 16; EER: 12.5; Nom. Tons: 5; BtuH Cooling: 57,500; BtuH Heating Input: 65,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.2; COP: 3.6; Nom. CFM: 1,800; Min. Circuit Amps: 44.7; Refrigerant: R410A; Width: 45-3/4"; Height: 55"; Depth: 51-1/4"; Wt. Lbs.: 577;
Brand: Coleman Mfg #: PHG6B600652X1

Single Packaged Gas/Electric Air Conditioner 16 SEER, Single-Phase, 5 Ton, 81% AFUE, R410A, Multi-Position B63-644
Single Packaged Gas/Electric Air Conditioner 16 SEER, Single-Phase, 5 Ton, 81% AFUE, R410A, Multi-Position
SEER: 16; EER: 12.0; Nom. Tons: 5; BtuH Cooling: 58,000; BtuH Heating Input: 138,000; BtuH Heating Output: 112,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Nom. CFM: 2,000; Min. Circuit Amps: 43.4; Refrigerant: R410A; Width: 48-49/250"; Height: 42-21/25"; Depth: 73-189/200"; Wt. Lbs.: 655;
Brand: Goodman Mfg #: GPG1660140M41

Single Packaged Gas/Heat Air Conditioner 16 SEER, Three-Phase, 5 Ton, R410A, 81% AFUE, 460V B64-241
Single Packaged Gas/Heat Air Conditioner 16 SEER, Three-Phase, 5 Ton, R410A, 81% AFUE, 460V
SEER: 16; EER: 12.0; Nom. Tons: 5; BtuH Cooling: 59,000; BtuH Heating Input: 100,000; BtuH Heating Output: 81,000; Volts: 460; Phase: Three; Motor Type: ECM; Nom. CFM: 1,825; Min. Circuit Amps: 12.3; Refrigerant: R410A; Width: 45-3/4"; Height: 50"; Depth: 51-1/4"; Wt. Lbs.: 541;
Brand: Coleman Mfg #: PCG6B601004X4

Single Packaged Gas/Heat Air Conditioner 16 SEER, Three-Phase, 4 Ton, R410A, 81% AFUE, 460V B64-240
Single Packaged Gas/Heat Air Conditioner 16 SEER, Three-Phase, 4 Ton, R410A, 81% AFUE, 460V
SEER: 16; EER: 12.0; Nom. Tons: 4; BtuH Cooling: 46,000; BtuH Heating Input: 125,000; BtuH Heating Output: 101,000; Volts: 460; Phase: Three; Motor Type: ECM; Nom. CFM: 1,550; Min. Circuit Amps: 11.3; Refrigerant: R410A; Width: 45-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 533;
Brand: Coleman Mfg #: PCG6B481254X4

Single Packaged Gas/Heat Air Conditioner 16 SEER, Three-Phase, 4 Ton, R410A, 81% AFUE, 208/230V B64-234
Single Packaged Gas/Heat Air Conditioner 16 SEER, Three-Phase, 4 Ton, R410A, 81% AFUE, 208/230V
SEER: 16; EER: 12.0; Nom. Tons: 4; BtuH Cooling: 46,000; BtuH Heating Input: 65,000; BtuH Heating Output: 52,000; Volts: 208/230; Phase: Three; Motor Type: ECM; Nom. CFM: 1,550; Min. Circuit Amps: 21.8; Refrigerant: R410A; Width: 45-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 520;
Brand: Coleman Mfg #: PCG6B480653X4

Single Packaged Gas/Heat Air Conditioner 16 SEER, Three-Phase, 4 Ton, R410A, 81% AFUE, 208/230V B64-235
Single Packaged Gas/Heat Air Conditioner 16 SEER, Three-Phase, 4 Ton, R410A, 81% AFUE, 208/230V
SEER: 16; EER: 12.0; Nom. Tons: 4; BtuH Cooling: 46,000; BtuH Heating Input: 100,000; BtuH Heating Output: 81,000; Volts: 208/230; Phase: Three; Motor Type: ECM; Nom. CFM: 1,550; Min. Circuit Amps: 21.8; Refrigerant: R410A; Width: 45-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 528;
Brand: Coleman Mfg #: PCG6B481003X4

Single Packaged Gas/Heat Air Conditioner 16 SEER, Three-Phase, 4 Ton, R410A, 81% AFUE, 460V B64-239
Single Packaged Gas/Heat Air Conditioner 16 SEER, Three-Phase, 4 Ton, R410A, 81% AFUE, 460V
SEER: 16; EER: 12.0; Nom. Tons: 4; BtuH Cooling: 46,000; BtuH Heating Input: 100,000; BtuH Heating Output: 81,000; Volts: 460; Phase: Three; Motor Type: ECM; Nom. CFM: 1,550; Min. Circuit Amps: 11.3; Refrigerant: R410A; Width: 45-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 528;
Brand: Coleman Mfg #: PCG6B481004X4

Single Packaged Gas/Heat Air Conditioner 16 SEER, Three-Phase, 5 Ton, R410A, 81% AFUE, 208/230V B64-236
Single Packaged Gas/Heat Air Conditioner 16 SEER, Three-Phase, 5 Ton, R410A, 81% AFUE, 208/230V
SEER: 16; EER: 12.0; Nom. Tons: 5; BtuH Cooling: 59,000; BtuH Heating Input: 65,000; BtuH Heating Output: 52,000; Volts: 208/230; Phase: Three; Motor Type: ECM; Nom. CFM: 1,825; Min. Circuit Amps: 26.2; Refrigerant: R410A; Width: 45-3/4"; Height: 50"; Depth: 51-1/4"; Wt. Lbs.: 537;
Brand: Coleman Mfg #: PCG6B600653X4

Single Packaged Gas/Heat Air Conditioner 16 SEER, Three-Phase, 5 Ton, R410A, 81% AFUE, 208/230V B64-237
Single Packaged Gas/Heat Air Conditioner 16 SEER, Three-Phase, 5 Ton, R410A, 81% AFUE, 208/230V
SEER: 16; EER: 12.0; Nom. Tons: 5; BtuH Cooling: 59,000; BtuH Heating Input: 100,000; BtuH Heating Output: 81,000; Volts: 208/230; Phase: Three; Motor Type: ECM; Nom. CFM: 1,825; Min. Circuit Amps: 26.2; Refrigerant: R410A; Width: 45-3/4"; Height: 50"; Depth: 51-1/4"; Wt. Lbs.: 541;
Brand: Coleman Mfg #: PCG6B601003X4

Heat Pump LX Series, 16 SEER, Single-Phase, Modulating, 5 Ton, R410A B78-409
Heat Pump LX Series, 16 SEER, Single-Phase, Modulating, 5 Ton, R410A
SEER: 16; EER: 10; Nom. Tons: 5; BtuH Cooling: 56,000; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.0; COP: 4.22; Min. Circuit Amps: 34.7; Max. Fuse Size: 60; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 35-1/4"; Height: 39-1/2";…
Brand: Coleman Mfg #: CH16B6021S

Heat Pump 16 SEER, Two-Stage, Single-Phase, 4 Ton, R410A B91-188
Heat Pump 16 SEER, Two-Stage, Single-Phase, 4 Ton, R410A
SEER: 16; EER: 13.0; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 48,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 9.7; COP: 4.54; Min. Circuit Amps: 27.7; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 38-1/4";…
Brand: Amana Mfg #: ASZC160481

Air Conditioning Condensing Unit 16 SEER, Single-Phase, 4 Ton, R410A B73-985
Air Conditioning Condensing Unit 16 SEER, Single-Phase, 4 Ton, R410A
SEER: 16; EER: 12.0; Nom. Tons: 4; BtuH Cooling: 45,500; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 23.9; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 38-1/4"; Depth: 35-1/2"; Wt. Lbs.: 241; OEM TXV: B18-726;
Brand: Amana Mfg #: ASX160481

Air Conditioning Condensing Unit 16 SEER, Single-Phase, 5 Ton, R410A B73-986
Air Conditioning Condensing Unit 16 SEER, Single-Phase, 5 Ton, R410A
SEER: 16; EER: 12.5; Nom. Tons: 5; BtuH Cooling: 54,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 28.3; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 38-1/4"; Depth: 35-1/2"; Wt. Lbs.: 301; OEM TXV: B18-727;
Brand: Amana Mfg #: ASX160601

Air Conditioning Condensing Unit 16 SEER, Two-Stage, Single-Phase, 4 Ton, R410A B91-181
Air Conditioning Condensing Unit 16 SEER, Two-Stage, Single-Phase, 4 Ton, R410A
SEER: 16; EER: 12.5; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 27.7; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-3/4"; Height: 37"; Depth: 35-3/4"; Wt. Lbs.: 282; OEM TXV: B14-851;
Brand: Amana Mfg #: ASXC160481

Heat Pump 16 SEER, Single-Phase, 4 Ton, R410A B77-549
Heat Pump 16 SEER, Single-Phase, 4 Ton, R410A
SEER: 16; EER: 13.0; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 48,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.5; COP: 4.75; Min. Circuit Amps: 26.4; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 34-5/8";…
Brand: Amana Mfg #: ASZ160481

Heat Pump LX Series, 16 SEER, Single-Phase, Modulating, 4 Ton, R410A B78-408
Heat Pump LX Series, 16 SEER, Single-Phase, Modulating, 4 Ton, R410A
SEER: 16; EER: 10; Nom. Tons: 4; BtuH Cooling: 47,000; BtuH Heating Input: 48,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.0; COP: 4.28; Min. Circuit Amps: 35.6; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/4"; Height: 39-1/2";…
Brand: Coleman Mfg #: CH16B4821S